Headway™

Device-Type

Microcatheters

Targated Speciality

Endovascular

Disease Solution

Access Product Solutions

Manufacturer

MicroVention Terumo


Innovative Catheter Technology.


The Headway Microcatheter is intended for general intravascular use, including the peripheral, coronary and neuro vasculature for the infusion of diagnostic agents, such as contrast media, and therapeutic agents, such as occlusion coils.


Headway DUO

The Headway Duo Microcatheter is intended for general intravascular use, including the peripheral and coronary vasculature for the infusion of diagnostics agents, such as contrast media, and therapeutic agents, such as embolization materials.


The Headway Duo Microcatheter is intended for neurovascular use, for the infusion of diagnostic agents, such as contrast media, and therapeutic agents that have been cleared or approved for use in the neurovasculature and are compatible with the inner diameter of the Headway Duo Microcatheter.

Features and Benefits

Hybrid Braid/Coil Desgin

Tight pitch coil provides lumen integrity, bending flexibility and good shape retention. Proximal braid provides firmness and a torqueable catheter body. True 1:1 push/pull while tracking through tortuous anatomy.


Lubricious Hydrophilic Coating

Reduced friction for improved navigation in tortuous vessels. Exceptional durability for prolonged use.


Liquid Embolic Compatibility

Compatible with Onyx™ Liquid Embolic, nBCA and DMSO. High burst strength. Long length allows distal lesion access.




Recommended Compatible Devices

Liquid embolic compatible (DMSO, Onyx, nBCA). The recommended guidewires are Traxcess 14 Guidewire, Traxcess 14 SELECT Guidewire, and Traxcess 14 EX Guidewire.

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Tip Description Tip Markers Tip ID Body ID Distal OD Proximal OD Usable Length
Headway 17 Advanced
MC172150SX Straight 2 0.017 in 0.017 in 1.7 F 2.4 F 150 cm
Headway 17 Advanced - 45
MC17215045X Pre-shaped 45 2 0.017 in 0.017 in 1.7 F 2.4 F 150 cm
Headway 17 Advanced - 90
MC17215090X Pre-shaped 90 2 0.017 in 0.017 in 1.7 F 2.4 F 150 cm
Headway 17 Advanced - J
MC172150JX Pre-shaped J 2 0.017 in 0.017 in 1.7 F 2.4 F 150 cm
Headway 17 Advanced Soft
MC172150S Straight 2 0.017 in 0.017 in 1.7 F 2.4 F 150 cm
Headway 21
MC212150S Straight 2 0.021 in 0.021 in 2.0 F 2.5 F 150 cm
Headway 21 - 156
MC212156S Straight 2 0.021 in 0.021 in 2.0 F 2.5 F 156 cm
Headway 27
MC272150S Straight 2 0.027 in 0.027 in 2.6 F 3.1 F 150 cm
Headway 27 - 156
MC272156S Straight 2 0.027 in 0.027 in 2.6 F 3.1 F 156 cm
Headway DUO 156
MC162156S Straight 2 0.0165 in 0.0165 in 1.6 F 2.1 F 156 cm
Headway DUO 167
MC162167S Straight 1 0.013 in 0.0165 in 1.3 F 2.1 F 167 cm
device-thumbnail
Headway 17 Advanced
  • Model : MC172150SX
  • Procedure : -
  • Tip Description : Straight
  • Tip Markers : 2
  • Tip ID : 0.017 in
  • Body ID : 0.017 in
  • Distal OD : 1.7 F
  • Proximal OD : 2.4 F
  • Usable Length : 150 cm
  • Model : MC17215045X
  • Procedure : -
  • Tip Description : Pre-shaped 45
  • Tip Markers : 2
  • Tip ID : 0.017 in
  • Body ID : 0.017 in
  • Distal OD : 1.7 F
  • Proximal OD : 2.4 F
  • Usable Length : 150 cm
  • Model : MC17215090X
  • Procedure : -
  • Tip Description : Pre-shaped 90
  • Tip Markers : 2
  • Tip ID : 0.017 in
  • Body ID : 0.017 in
  • Distal OD : 1.7 F
  • Proximal OD : 2.4 F
  • Usable Length : 150 cm
  • Model : MC172150JX
  • Procedure : -
  • Tip Description : Pre-shaped J
  • Tip Markers : 2
  • Tip ID : 0.017 in
  • Body ID : 0.017 in
  • Distal OD : 1.7 F
  • Proximal OD : 2.4 F
  • Usable Length : 150 cm
  • Model : MC172150S
  • Procedure : -
  • Tip Description : Straight
  • Tip Markers : 2
  • Tip ID : 0.017 in
  • Body ID : 0.017 in
  • Distal OD : 1.7 F
  • Proximal OD : 2.4 F
  • Usable Length : 150 cm
device-thumbnail
Headway 21
  • Model : MC212150S
  • Procedure : -
  • Tip Description : Straight
  • Tip Markers : 2
  • Tip ID : 0.021 in
  • Body ID : 0.021 in
  • Distal OD : 2.0 F
  • Proximal OD : 2.5 F
  • Usable Length : 150 cm
device-thumbnail
Headway 21 - 156
  • Model : MC212156S
  • Procedure : -
  • Tip Description : Straight
  • Tip Markers : 2
  • Tip ID : 0.021 in
  • Body ID : 0.021 in
  • Distal OD : 2.0 F
  • Proximal OD : 2.5 F
  • Usable Length : 156 cm
device-thumbnail
Headway 27
  • Model : MC272150S
  • Procedure : -
  • Tip Description : Straight
  • Tip Markers : 2
  • Tip ID : 0.027 in
  • Body ID : 0.027 in
  • Distal OD : 2.6 F
  • Proximal OD : 3.1 F
  • Usable Length : 150 cm
device-thumbnail
Headway 27 - 156
  • Model : MC272156S
  • Procedure : -
  • Tip Description : Straight
  • Tip Markers : 2
  • Tip ID : 0.027 in
  • Body ID : 0.027 in
  • Distal OD : 2.6 F
  • Proximal OD : 3.1 F
  • Usable Length : 156 cm
device-thumbnail
Headway DUO 156
  • Model : MC162156S
  • Procedure : -
  • Tip Description : Straight
  • Tip Markers : 2
  • Tip ID : 0.0165 in
  • Body ID : 0.0165 in
  • Distal OD : 1.6 F
  • Proximal OD : 2.1 F
  • Usable Length : 156 cm
device-thumbnail
Headway DUO 167
  • Model : MC162167S
  • Procedure : -
  • Tip Description : Straight
  • Tip Markers : 1
  • Tip ID : 0.013 in
  • Body ID : 0.0165 in
  • Distal OD : 1.3 F
  • Proximal OD : 2.1 F
  • Usable Length : 167 cm

Questions & Answers

Don't see the answer you're looking for ?