Manufacturer > MicroVention Terumo > Devices > Scepter C™ & Scepter XC™

Scepter C™ & Scepter XC™

Device-Type

Specialty Balloons (Neuro)

Targated Speciality

Cardiovascular,  Neuro vascular

Disease Solution

Access Product Solutions

Manufacturer

MicroVention Terumo


The Scepter balloon offers VERSATILITY with clinical applications in four key areas: Balloon Remodeling, Stent Delivery, Liquid Embolic Injection, and Balloon-Test Occlusion.

For use in the blood vessels of the peripheral and neurovasculature where temporary occlusion is desired. These catheters offer a vessel selective technique of temporary vascular occlusion which is useful in selectively stopping or controlling blood flow and for balloon assisted embolization of intracranial aneurysms.

For use in the peripheral vasculature for the infusion of diagnostic agents, such as contrast media, and therapeutic agents, such as embolization materials.

For neurovascular use for the infusion of diagnostic agents, such as contrast media, and therapeutic agents, such as embolization materials, that have been approved or cleared for use in the neurovasculature and are compatible with the inner diameter of the Scepter C/XC Balloon Catheter.

Features and Benefits

Stability & Trackability

Coil reinforced shaft for enhanced trackability and excellent stability.

Dual lumen design that can accommodate any 0.014" guidewire.


Distal Navigation & Emobilzation

Hydrophilic coating for reduced friction and improved navigation in tortuous vessels. Balloon provides back stop and flow reduction to limit reflux during liquid embolic injection.


Stent Delivery with Ease

Balloon remodeling and stent delivery without catheter exchange

Recommended Compatible Devices

The Scepter C & XC occlusion balloons are compatible with:

  • DMSO based Liquid Embolics
  • A maximum guidewire OD of 0.014”
  • MicroVention’s Traxcess Docking Wire

Safety informations

INDICATIONS FOR USE

  • For use in the blood vessels of the peripheral and neurovasculature where temporary occlusion is desired. These catheters offer a vessel selective technique of temporary vascular occlusion which is useful in selectively stopping or controlling blood flow and for balloon assisted embolization of intracranial aneurysms.
  • For use in the peripheral vasculature for the infusion of diagnostic agents, such as contrast media, and therapeutic agents, such as embolization materials.
  • For neurovascular use for the infusion of diagnostic agents, such as contrast media, and therapeutic agents, such as embolization materials, that have been approved or cleared for use in the neurovasculature and are compatible with the inner diameter of the Scepter C/XC Balloon Catheter.


Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Nominal Balloon Diameter(mm) Working Balloon Range(mm) Balloon Length(mm) Tip Length(mm) Catheter Working Length(cm) Inflation Lumen Dead Volume(cc) Balloon Inflation Volume(Nominal) Proximal Shaft OD(f) Distal Tip OD Inner Lumen Diameter(in) undefined
Scepter C
BC0410C 4 2.0-5.0 10 5 150 0.40cc 0.16cc 2.8 2.1 0.0165
Scepter C
BC0415C 4 2.0-5.0 15 5 150 0.40cc 0.18cc 2.8 2.1 0.0165 -
Scepter C
BC0420C 4 2.0-5.0 20 5 150 0.40cc 0.22cc 2.8 2.1 0.0165 -
Scepter XC
BC0411XC 4 2.0-6.0 11 5 150 0.40cc 0.10cc 2.8 2.1 0.0165 -
device-thumbnail
Scepter C
  • Model : BC0410C
  • Procedure : -
  • Nominal Balloon Diameter(mm) : 4
  • Working Balloon Range(mm) : 2.0-5.0
  • Balloon Length(mm) : 10
  • Tip Length(mm) : 5
  • Catheter Working Length(cm) : 150
  • Inflation Lumen Dead Volume(cc) : 0.40cc
  • Balloon Inflation Volume(Nominal) : 0.16cc
  • Proximal Shaft OD(f) : 2.8
  • Distal Tip OD : 2.1
  • Inner Lumen Diameter(in) : 0.0165
  • undefined :
device-thumbnail
Scepter C
  • Model : BC0415C
  • Procedure : -
  • Nominal Balloon Diameter(mm) : 4
  • Working Balloon Range(mm) : 2.0-5.0
  • Balloon Length(mm) : 15
  • Tip Length(mm) : 5
  • Catheter Working Length(cm) : 150
  • Inflation Lumen Dead Volume(cc) : 0.40cc
  • Balloon Inflation Volume(Nominal) : 0.18cc
  • Proximal Shaft OD(f) : 2.8
  • Distal Tip OD : 2.1
  • Inner Lumen Diameter(in) : 0.0165
device-thumbnail
Scepter C
  • Model : BC0420C
  • Procedure : -
  • Nominal Balloon Diameter(mm) : 4
  • Working Balloon Range(mm) : 2.0-5.0
  • Balloon Length(mm) : 20
  • Tip Length(mm) : 5
  • Catheter Working Length(cm) : 150
  • Inflation Lumen Dead Volume(cc) : 0.40cc
  • Balloon Inflation Volume(Nominal) : 0.22cc
  • Proximal Shaft OD(f) : 2.8
  • Distal Tip OD : 2.1
  • Inner Lumen Diameter(in) : 0.0165
device-thumbnail
Scepter XC
  • Model : BC0411XC
  • Procedure : -
  • Nominal Balloon Diameter(mm) : 4
  • Working Balloon Range(mm) : 2.0-6.0
  • Balloon Length(mm) : 11
  • Tip Length(mm) : 5
  • Catheter Working Length(cm) : 150
  • Inflation Lumen Dead Volume(cc) : 0.40cc
  • Balloon Inflation Volume(Nominal) : 0.10cc
  • Proximal Shaft OD(f) : 2.8
  • Distal Tip OD : 2.1
  • Inner Lumen Diameter(in) : 0.0165

Questions & Answers

Don't see the answer you're looking for ?