Manufacturer > Cordis > Devices > ANGIOGUARD® RX Guidewire System

ANGIOGUARD® RX Guidewire System

Device-Type

Embolic Protection

Manufacturer

Cordis


The Cordis ANGIOGUARD® RX Emboli Capture Guidewire System is indicated for use as a guidewire and embolic protection system to contain and remove embolic material (thrombus/debris) while performing carotid artery angioplasty and stenting procedures in carotid arteries. The diameter of the artery at the site of filter basket placement should be from 3mm to 7.5mm (see Instructions for Use for basket/vessel sizing).


With its Rapid Exchange System is easy to use, providing optimal protection while maintaining blood flow.


Ease of Use Medium & Extra Support Wires

• .014” compatible wire available in medium and extra support for lesion specific access and support of interventional devices


Excellent crossability

• Easy to cross tortuous anatomies with a crossing profile from as low as 3.2F


Rapid Exchange System

• Simplified deployment with peel away deployment sheath

• Easy capture of filter with rapid exchange capture sheath

• Single operator

• Faster procedure

• Enhanced wire control


Capture Effectiveness

• Effective capture of clinically relevant emboli with 100μ pore sizes filter

• Optimal wall apposition


Safety

• Continuous perfusion throughout the procedure

• Excellent visualisation and optimal control

• 4 radiopaque markers on the basket

• Proximal and distal markerbands

• Effect sealing of the vessel preventing migration of emboli (when properly sized)

• Designed to minimize vessel trauma

• Tapered delivery and capture sheaths

• Coil nosecone to improve wire transition 

Features and Benefits

Medium & Extra Support Wires

• .014” compatible wire available in medium and extra support for lesion specific access and support of interventional devices

Excellent crossability

• Easy to cross tortuous anatomies with a crossing profile from as low as 3.2F

Rapid Exchange System

• Simplified deployment with peel away deployment sheath

• Easy capture of filter with rapid exchange capture sheath

• Single operator

• Faster procedure

• Enhanced wire control

Safety informations

Contraindications

  • Patients in whom antiplatelet and or anticoagulation therapy is contraindicated.
  • Patients in whom the guide catheter is unable to be placed.
  • Patients with uncorrected bleeding disorders.
  • Patients with known allergies to nitinol.
  • Lesions in the ostium of the common carotid artery.

Warnings

  • Only physicians who have received appropriate training for carotid stenting and who are familiar with the principles, clinical applications, complications, side effects and hazards commonly associated with carotid interventional procedures should use this device.
  • The safety and effectiveness of this device as an emboli protection system has not been established in the coronary, cerebral, or peripheral vasculature, other than carotid arteries.
  • The safety and efficacy of the ANGIOGUARD® RX Guidewire System have not been demonstrated with stent systems other than the PRECISE® Stent System.
  • Overstretching of the artery may result in rupture and life-threatening bleeding.
  • Patient ACT of >300 seconds needs to be maintained during ANGIOGUARD® RX Guidewire System deployment.

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Guidewire Diameter (in) System Length (cm) Filter Basket Diameter (mm) Recommended Vessel Diameter For Placement (mm) Crossing Profile (F)
ANGIOGUARD® RX Emboli Capture Guidewire System
401814RMC 0.014 180 4 3 to < 3.5 3.2
ANGIOGUARD® RX Emboli Capture Guidewire System
501814RMC 0.014 180 5 3.5 to < 4.5 3.3
ANGIOGUARD® RX Emboli Capture Guidewire System
601814RMC 0.014 180 6 4.5 to < 5.5 3.5
ANGIOGUARD® RX Emboli Capture Guidewire System
701814RMC 0.014 180 7 5.5 to < 6.5 3.7
ANGIOGUARD® RX Emboli Capture Guidewire System
801814RMC 0.014 180 8 6.5 to < 7.5 3 3.9
ANGIOGUARD® RX Emboli Capture Guidewire System
403014MC 0.014 180 4 3 to < 3.5 3.2
ANGIOGUARD® RX Emboli Capture Guidewire System
503014MC 0.014 180 5 3.5 to < 4.5 3.3
ANGIOGUARD® RX Emboli Capture Guidewire System
603014MC 0.014 180 6 4.5 to < 5.5 3.5
ANGIOGUARD® RX Emboli Capture Guidewire System
703014MC 0.014 180 7 5.5 to < 6.5 3.7
ANGIOGUARD® RX Emboli Capture Guidewire System
501814REC 0.014 180 5 3.5 to < 4.5 3.3
ANGIOGUARD® RX Emboli Capture Guidewire System
601814REC 0.014 180 6 4.5 to < 5.5 3.5
  • Model : 401814RMC
  • Procedure : -
  • Guidewire Diameter (in) : 0.014
  • System Length (cm) : 180
  • Filter Basket Diameter (mm) : 4
  • Recommended Vessel Diameter For Placement (mm) : 3 to < 3.5
  • Crossing Profile (F) : 3.2
  • Model : 501814RMC
  • Procedure : -
  • Guidewire Diameter (in) : 0.014
  • System Length (cm) : 180
  • Filter Basket Diameter (mm) : 5
  • Recommended Vessel Diameter For Placement (mm) : 3.5 to < 4.5
  • Crossing Profile (F) : 3.3
  • Model : 601814RMC
  • Procedure : -
  • Guidewire Diameter (in) : 0.014
  • System Length (cm) : 180
  • Filter Basket Diameter (mm) : 6
  • Recommended Vessel Diameter For Placement (mm) : 4.5 to < 5.5
  • Crossing Profile (F) : 3.5
  • Model : 701814RMC
  • Procedure : -
  • Guidewire Diameter (in) : 0.014
  • System Length (cm) : 180
  • Filter Basket Diameter (mm) : 7
  • Recommended Vessel Diameter For Placement (mm) : 5.5 to < 6.5
  • Crossing Profile (F) : 3.7
  • Model : 801814RMC
  • Procedure : -
  • Guidewire Diameter (in) : 0.014
  • System Length (cm) : 180
  • Filter Basket Diameter (mm) : 8
  • Recommended Vessel Diameter For Placement (mm) : 6.5 to < 7.5 3
  • Crossing Profile (F) : 3.9
  • Model : 403014MC
  • Procedure : -
  • Guidewire Diameter (in) : 0.014
  • System Length (cm) : 180
  • Filter Basket Diameter (mm) : 4
  • Recommended Vessel Diameter For Placement (mm) : 3 to < 3.5
  • Crossing Profile (F) : 3.2
  • Model : 503014MC
  • Procedure : -
  • Guidewire Diameter (in) : 0.014
  • System Length (cm) : 180
  • Filter Basket Diameter (mm) : 5
  • Recommended Vessel Diameter For Placement (mm) : 3.5 to < 4.5
  • Crossing Profile (F) : 3.3
  • Model : 603014MC
  • Procedure : -
  • Guidewire Diameter (in) : 0.014
  • System Length (cm) : 180
  • Filter Basket Diameter (mm) : 6
  • Recommended Vessel Diameter For Placement (mm) : 4.5 to < 5.5
  • Crossing Profile (F) : 3.5
  • Model : 703014MC
  • Procedure : -
  • Guidewire Diameter (in) : 0.014
  • System Length (cm) : 180
  • Filter Basket Diameter (mm) : 7
  • Recommended Vessel Diameter For Placement (mm) : 5.5 to < 6.5
  • Crossing Profile (F) : 3.7
  • Model : 501814REC
  • Procedure : -
  • Guidewire Diameter (in) : 0.014
  • System Length (cm) : 180
  • Filter Basket Diameter (mm) : 5
  • Recommended Vessel Diameter For Placement (mm) : 3.5 to < 4.5
  • Crossing Profile (F) : 3.3
  • Model : 601814REC
  • Procedure : -
  • Guidewire Diameter (in) : 0.014
  • System Length (cm) : 180
  • Filter Basket Diameter (mm) : 6
  • Recommended Vessel Diameter For Placement (mm) : 4.5 to < 5.5
  • Crossing Profile (F) : 3.5