AngioJet™

Device-Type

Mechanical Thrombectomy

Manufacturer

Boston Scientific


The AngioJet Thrombectomy System is a pharmacomechanical peripheral thrombectomy device with active aspiration and Power Pulse™ lytic delivery designed to treat the widest range of thrombosed vessels, rapidly restoring blood flow.

Features and Benefits

The AngioJet Thrombectomy system provides the power and flexibility for rapid thrombus removal, quick restoration of blood flow, symptom improvement and ease of use.

  • Active aspiration and Power Pulse lytic delivery for tough clots
  • Wide offering of catheters for treating arterial, venous and AV access in vessels ranging from 1.5 mm to large iliofemoral clot burdens
  • Compact, highly mobile console design

Use Case Examples

The AngioJet SOLENT Proxi & Omni Thrombectomy Sets are intended for use with the AngioJet Ultra Console to break apart and remove thrombus from:

  • Upper and lower extremity peripheral arteries ≥ 3.0mm in diameter
  • Upper extremity peripheral veins ≥ 3.0mm in diameter
  • Ileofemoral and lower extremity veins ≥ 3.0mm in diameter
  • A-V access conduits ≥ 3.0mm in diameter and
  • For use with the AngioJet Ultra Power Pulse technique for the control and selective infusion of physician specified fluids, including thrombolytic agents, into the peripheral vascular system

The AngioJet SOLENT Dista Thrombectomy Set is intended for use with the AngioJet Ultra Console to break apartand remove thrombus from:

  • Upper and lower extremity peripheral arteries and
  • For use with the AngioJet Ultra Power Pulse technique for the control and selective infusion of physician specified fluids, including thrombolytic agents, into the peripheral vascular system. The minimum vessel diameter for each Thrombectomy Set model is listed in Table 1 (in the DFU).

The AngioJet Ultra Console is intended for use only in conjunction with an AngioJet Thrombectomy Set. Refer to the individual Thrombectomy Set Directions for Use manual for specific clinical applications.


The ZelanteDVT Thrombectomy Set is intended for use with the AngioJet Ultra Console to break apart and remove thrombus, including deep vein thrombus (DVT), from:

  • Iliofemoral and lower extremity veins ≥ 6.0 mm in diameter and
  • Upper extremity peripheral veins ≥ 6.0 mm in diameter.

The ZelanteDVT Thrombectomy Set is also intended for use with the AngioJet Ultra Power Pulse® technique for the controlled and selective infusion of physician specified fluids, including thrombolytic agents, into the peripheral vascular system.


The ZelanteDVT Thrombectomy System, which includes the ZelanteDVT Thrombectomy Set and the ClotHunter Helical Rotation Device, is intended for use with the AngioJet Ultra Console to break apart and remove thrombus,including deep vein thrombus (DVT), from:

  • iliofemoral and lower extremity veins ≥ 6.0 mm in diameter and
  • upper extremity peripheral veins ≥ 6.0 mm in diameter.

The ZelanteDVT Thrombectomy System is also intended for use with the AngioJet Ultra Power Pulse technique for the controlled and selective infusion of physician-specified fluids, including thrombolytic agents, into the peripheral vascular system.


The AngioJet Ultra AVX Thrombectomy Set is intended for use with the AngioJet Ultra System in breaking apart and removing thrombus from A-V access conduits ≥ 3.0 mm in diameter.

Safety informations

AngioJet Solent Omni Proxi

Do not use the Thrombectomy Set in patients:

  • Who are contraindicated for endovascular procedures
  • In whom the lesion cannot be accessed with the guide wire
  • Who cannot tolerate contrast media

AngioJet Solent Dista

Do not use the catheter in patients:

  • Who are contraindicated for endovascular procedures
  • In whom the lesion cannot be accessed with the guide wire
  • Who cannot tolerate contrast media

AngioJet ZelanteDVT Thrombectomy Set

Do not use the catheter in patients:

  • Who are contraindicated for endovascular procedures
  • Who cannot tolerate contrast media
  • In whom the lesion cannot be accessed with the guidewire

ZelanteDVT ClotHunter

Do not use the ZelanteDVT Thrombectomy System in patients:

  • who are contraindicated for endovascular procedures.
  • in whom the lesion cannot be accessed with the guidewire.
  • who cannot tolerate contrast media.

AngioJet Ultra AVX Thrombectomy Set

Do not use the Thrombectomy Set in patients:

  • Who are contraindicated for endovascular procedures
  • In whom the lesion cannot be accessed with the guide wire
  • Who cannot tolerate contrast media

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Indication Delivery Platform Minimum Vessel Diameter Catheter Length Catheter Diameter Guidewire Power Pulse™ Enabled Guidewire Swappable Contrast Injection Port
AngioJet AVX™
105039-001 AV Access Grafts and Fistula OTW 3 mm 50 cm 6 F 0.035” N/A N/A Yes
AngioJet Solent™ Dista
111303-001 Peripheral Arterial OTW 1.5 mm 145 cm 4 F / 3 F 0.014” Yes N/A N/A
AngioJet Solent™ Omni
109681-001 Peripheral Arterial and Venous, AV Access OTW 3 mm 120 cm 6 F 0.035” Yes Yes Yes
AngioJet Solent™ Proxi
109676-001 Peripheral Arterial and Venous, AV Access OTW 3 mm 90 cm 6 F 0.035” Yes Yes Yes
AngioJet ZelanteDVT™
114610-001 Venous OTW 6 mm 105 cm 8 F 0.035” Yes Yes Yes
device-thumbnail
AngioJet AVX™
  • Model : 105039-001
  • Procedure : -
  • Indication : AV Access Grafts and Fistula
  • Delivery Platform : OTW
  • Minimum Vessel Diameter : 3 mm
  • Catheter Length : 50 cm
  • Catheter Diameter : 6 F
  • Guidewire : 0.035”
  • Power Pulse™ Enabled : N/A
  • Guidewire Swappable : N/A
  • Contrast Injection Port : Yes
  • Model : 111303-001
  • Procedure : -
  • Indication : Peripheral Arterial
  • Delivery Platform : OTW
  • Minimum Vessel Diameter : 1.5 mm
  • Catheter Length : 145 cm
  • Catheter Diameter : 4 F / 3 F
  • Guidewire : 0.014”
  • Power Pulse™ Enabled : Yes
  • Guidewire Swappable : N/A
  • Contrast Injection Port : N/A
  • Model : 109681-001
  • Procedure : -
  • Indication : Peripheral Arterial and Venous, AV Access
  • Delivery Platform : OTW
  • Minimum Vessel Diameter : 3 mm
  • Catheter Length : 120 cm
  • Catheter Diameter : 6 F
  • Guidewire : 0.035”
  • Power Pulse™ Enabled : Yes
  • Guidewire Swappable : Yes
  • Contrast Injection Port : Yes
  • Model : 109676-001
  • Procedure : -
  • Indication : Peripheral Arterial and Venous, AV Access
  • Delivery Platform : OTW
  • Minimum Vessel Diameter : 3 mm
  • Catheter Length : 90 cm
  • Catheter Diameter : 6 F
  • Guidewire : 0.035”
  • Power Pulse™ Enabled : Yes
  • Guidewire Swappable : Yes
  • Contrast Injection Port : Yes
  • Model : 114610-001
  • Procedure : -
  • Indication : Venous
  • Delivery Platform : OTW
  • Minimum Vessel Diameter : 6 mm
  • Catheter Length : 105 cm
  • Catheter Diameter : 8 F
  • Guidewire : 0.035”
  • Power Pulse™ Enabled : Yes
  • Guidewire Swappable : Yes
  • Contrast Injection Port : Yes