ARMADA 18 PTA CATHETER

Device-Type

PTA Ballons

Manufacturer

Abbott


EXTENDED LENGTHS AND SIZES

  • Longer balloon lengths allow for efficient dilatation of long below-the-knee lesions
  • Unique diameters provide accurate dilatation of lesions in the SFA
  • Catheter lengths of 90 cm and 150 cm
  • 4F and 5F compatibility

OUTSTANDING PERFORMANCE

  • Transitionless co-axial design for outstanding pushability and guide wire trackability
  • One-piece catheter construction results in a large contrast lumen that minimizes deflation time
  • JETCOAT™ hydrophobic coating for smooth tracking and lesion crossing


Features and Benefits

TIP DESIGN OPTIMIZES LESION ENTRY AND CROSS

Armada 18 Catheter SFA Tip EntryArmada 18 Catheter BTK Tip EntryONE-PIECE CATHETER CONSTRUCTION

RESULTS IN A LARGE CONTRAST LUMEN

THAT MINIMIZES DEFLATION TIME

Armada 18 Catheter DesignArmada 18 Deflation Time Chart

Safety informations

INDICATIONS

Armada 18 is indicated to dilate stenosis in femoral, popliteal, infra-popliteal, and renal arteries and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. In addition, the device is also indicated for post-dilatation of balloon expandable and self-expanding stents

CONTRAINDICATIONS

  • Inability to cross lesion with a guide wire
  • Use in the coronary arteries

WARNINGS/PRECAUTIONS

  • This device should only be used by physicians who are experienced and have a thorough understanding of the clinical and technical aspects of PTA
  • One-time use only – do not resterilize! This single use device cannot be reused on another patient, as it is not designed to perform as intended after the first usage. Changes in mechanical, physical, and/or chemical characteristics introduced under conditions of repeated use, cleaning, and/or resterilization may compromise the integrity of the design and/or materials, leading to contamination due to narrow gaps and/or spaces and diminished safety and/or performance of the device. Absence of original labeling may lead to misuse and eliminate traceability. Absence of original packaging may lead to device damage, loss of sterility, and risk of injury to patient and/or user
  • Do not use if inner package is damaged or opened
  • Employ aseptic techniques during removal from the package and during use
  • Any use for procedures other than those indicated in these instructions is not recommended
  • Use prior to the use by date
  • Carefully inspect the catheter prior to use to verify that it has not been damaged during shipment and that its size, shape and condition are suitable for the procedure for which it is to be used
  • Precautions to prevent or reduce blood clotting should be taken when any catheter is used
  • Flush or rinse all products entering the vascular system with sterile isotonic saline or a similar solution via the guide wire access port prior to use. Consider the use of systemic heparinization
  • When the system is introduced into the vascular system, it should be manipulated only under high quality fluoroscopy
  • The Armada 18 PTA Catheter must always be introduced, moved and/or withdrawn over a guide wire (max. 0.018″)
  • Never attempt to move the guide wire when the balloon is inflated
  • Never use air or any gaseous medium to inflate the balloon
  • Do not advance the Armada 18 PTA Catheter against significant resistance. The cause of resistance should be determined via fluoroscopy and remedial action taken
  • The minimal acceptable sheath French size is printed on the package label. Do not attempt to pass the Armada 18 PTA Catheter through a smaller sized sheath introducer than indicated on the label
  • The size of the inflated balloon should be selected not to exceed the diameter of the artery immediately distal, or proximal, to the stenosis
  • Inflation in excess of the rated burst pressure may cause the balloon to rupture. Use of a pressure monitoring device is recommended
  • If a distal protection device is used, follow the manufacturer’s instruction for use. Allow and maintain adequate distance between the Armada 18 PTA Catheter and the distal protection device to avoid engagement
  • Rated burst pressure and balloon fatigue testing of the Armada 18 PTA balloons within deployed stents has demonstrated that the Armada 18 can safely post-dilate balloon expandable and self-expanding stents
  • When post-dilating stents, use a balloon length that is appropriate for the deployed stent length


Potential adverse events

The following complications may occur as a result of PTA, but may not be limited to:

  • Abrupt closure
  • Allergic reaction (contrast medium, drug, or stent material)
  • Aneurysm, pseudoaneurysm, or arteriovenous fistula
  • Angina or coronary ischemia
  • Arrhythmias (including premature beats, bradycardia, atrial or ventricular tachycardia, atrial or ventricular fibrillation)
  • Bleedingcomplications requiring transfusion or surgical intervention
  • Death
  • Detachment and / or implantation of a component of the system
  • Embolization, arterial or other (air, tissue, plaque, thrombotic material, device)
  • Emergent or urgent surgery
  • Fever
  • Hematoma or hemorrhagic event with or without surgical repair
  • Hyperperfusion syndrome
  • Hypotension or hypertension
  • Infection
  • Ischemia or infarction of tissue or organ not covered under other adverse events
  • Myocardial infarction
  • Pain (limb or catheter site)
  • Peripheral nerve injury
  • Pulmonary embolism
  • Renal failure or insufficiency
  • Restenosis of vessel
  • Shock
  • Stroke, cerebrovascular accident (CVA), or transient ischemic attack (TIA)
  • Target limb loss (amputation of toe, foot, and / or leg)
  • Vascular thrombosis or occlusion at puncture site, treatment site, or remote site
  • Venous thromboembolism
  • Vessel dissection, perforation, or rupture
  • Vessel spasm or recoil
  • Worsening claudication or rest pain