Manufacturer > BD > Devices > Atlas™

Atlas™

Device-Type

PTA Ballons

Targated Speciality

Angioplasty

Manufacturer

BD

Used in Procedure

Angioplasty


The Atlas PTA Balloon Dilatation is a high performance balloon catheter consisting of an over the wire catheter with a balloon fixed at the distal tip. The proprietary non-compliant, low profile balloon is designed to provide consistent balloon diameters and lengths even at high pressures. Two radiopaque markers delineate the working length of the balloon and aid in balloon placement. The coaxial catheter includes an atraumatic tip to facilitate advancement of the catheter to and through the stenosis. The over the wire catheter is compatible with 0.035" guidewire and is available in 75 and 120 cm working lengths. The proximal portion of the catheter includes a female luer lock hub connected to the inflation lumen, and a female luer-lock hub connected to the guidewire lumen.

Packaged with every product is a profile reducing sheath that is positioned over the balloon for protection before use. A re-wrapping tool is also provided on the catheter shaft.

This product is not manufactured with any latex.

Features and Benefits

  • Delivers maximum forces to areas of most resistance
  • Protects with ultra non-compliant technology
  • Virtually no balloon growth beyond stated diameter
  • Predictable balloon diameters
  • Reduces risk of overdilatation
  • Delivers High and Low pressure angioplasty

Safety informations

Indications for Use

Atlas PTA Balloon Dilatation Catheters are recommended for use in Percutaneous Transluminal Angioplasty of the iliac arteries and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This catheter is not for use in coronary arteries.


Contraindications

None known


Warnings

1. Contents supplied STERILE using ethylene oxide (EO). Non-Pyrogenic. Do not use if sterile barrier is opened or damaged. Single patient use only. Do not reuse, reprocess or re-sterilize.

2. This device has been designed for single use only. Reusing this medical device bears the risk of cross-patient contamination as medical devices – particularly those with long and small lumina, joints, and/or crevices between components – are difficult or impossible to clean once body fluids or tissues with potential pyrogenic or microbial contamination have had contact with the medical device for an indeterminable period of time. The residue of biological material can promote the contamination of the device with pyrogens or microorganisms which may lead to infectious complications.

3. Do not resterilize. After resterilization, the sterility of the product is not guaranteed because of an indeterminable degree of potential pyrogenic or microbial contamination which may lead to infectious complications. Cleaning, reprocessing and/or resterilization of the present medical device increases the probability that the device will malfunction due to potential adverse effects on components that are influenced by thermal and/or mechanical changes.

4. To reduce the potential for vessel damage, the inflated diameter and length of the balloon should approximate the diameter and length of the vessel just proximal and distal to the stenosis.

5. When the catheter is exposed to the vascular system, it should be manipulated while under high-quality fluoroscopic observation. Do not advance or retract the catheter unless the balloon is fully deflated. If resistance is met during manipulation, determine the cause of the resistance before proceeding. Applying excessive force to the catheter can result in tip breakage or balloon separation.

6. Do not exceed the RBP recommended for this device. Balloon rupture may occur if the RBP rating is exceeded. To prevent over pressurization, use of a pressure monitoring device is recommended.

7. After use, this product may be a potential biohazard. Handle and dispose of in accordance with acceptable medical practices and applicable local, state and federal laws and regulations.


Precautions

1. Carefully inspect the catheter prior to use to verify that catheter has not been damaged during shipment and that its size, shape and condition are suitable for the procedure for which it is to be used. Do not use if product damage is evident.

2. The Atlas catheter shall only be used by physicians trained in the performance of percutaneous transluminal angioplasty.

3. The minimal acceptable sheath French size is printed on the package label. Do not attempt to pass the PTA catheter through a smaller size sheath introducer than indicated on the label.

4. Use the recommended balloon inflation medium. Never use air or other gaseous medium to inflate the balloon.

5. If resistance is felt during post procedure withdrawal of the catheter, it is recommended to remove the balloon catheter and guidewire/introducer sheath as a single unit.

6. Do not continue to use the balloon catheter if the shaft has been bent or kinked.

7. Prior to re-insertion through the introducer sheath, the balloon should be wiped clean with gauze, rinsed with sterile normal saline, and refolded with the balloon re-wrap tool. Balloon re-wrapping should only occur while the balloon catheter is supported with a guidewire.

Potential adverse events

The complications which may result from a peripheral balloon dilatation procedure include:

• Additional intervention • Allergic reaction to drugs or contrast medium • Aneurysm or pseudoaneurysm • Arrhythmias • Embolization • Hematoma • Hemorrhage, including bleeding at the puncture site • Hypotension/hypertension • Inflammation • Occlusion • Pain or tenderness • Pneumothorax or hemothorax • Sepsis/infection • Shock • Short term hemodynamic deterioration • Stroke • Thrombosis • Vessel dissection, perforation, rupture, or spasm 

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Balloon Diameter (mm) Balloon Length (cm) Shaft Length (cm) Nominal Pressure (atm) Rated Burst Pressure (atm) Sheath Size (F)
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75122 12 2 75 6 18 7
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT120122 12 2 120 6 18 7
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75124 12 4 75 6 18 7
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT120124 12 4 120 6 18 7
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75126 12 6 75 6 18 7
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75142 14 2 75 6 18 7
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT120142 14 2 120 6 18 7
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75144 14 4 75 6 18 7
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT120144 14 4 120 6 18 7
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75146 14 6 75 6 18 8
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75162 16 2 75 6 18 8
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT120162 16 2 120 6 18 8
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75164 16 4 75 6 18 8
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT120164 16 4 120 6 18 8
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75166 16 4 75 6 18 8
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT120182 18 2 120 6 16 8
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75184 18 4 75 6 16 8
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT120184 18 4 120 6 16 8
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75186 18 6 75 6 16 9
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75202 20 2 75 6 16 9
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT120202 20 2 120 6 16 9
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75204 20 4 75 6 16 9
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT120204 20 4 120 6 16 9
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75222 22 2 75 4 14 10
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75224 22 4 75 4 14 10
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75242 24 2 75 4 14 10
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75244 24 4 75 4 14 10
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75262 26 2 75 4 12 12
Percutaneous Transluminal Angioplasty (PTA) Balloon
AT75264 26 4 75 4 12 12
  • Model : AT75122
  • Procedure : -
  • Balloon Diameter (mm) : 12
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : AT120122
  • Procedure : -
  • Balloon Diameter (mm) : 12
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : AT75124
  • Procedure : -
  • Balloon Diameter (mm) : 12
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : AT120124
  • Procedure : -
  • Balloon Diameter (mm) : 12
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : AT75126
  • Procedure : -
  • Balloon Diameter (mm) : 12
  • Balloon Length (cm) : 6
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : AT75142
  • Procedure : -
  • Balloon Diameter (mm) : 14
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : AT120142
  • Procedure : -
  • Balloon Diameter (mm) : 14
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : AT75144
  • Procedure : -
  • Balloon Diameter (mm) : 14
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : AT120144
  • Procedure : -
  • Balloon Diameter (mm) : 14
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : AT75146
  • Procedure : -
  • Balloon Diameter (mm) : 14
  • Balloon Length (cm) : 6
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 8
  • Model : AT75162
  • Procedure : -
  • Balloon Diameter (mm) : 16
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 8
  • Model : AT120162
  • Procedure : -
  • Balloon Diameter (mm) : 16
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 8
  • Model : AT75164
  • Procedure : -
  • Balloon Diameter (mm) : 16
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 8
  • Model : AT120164
  • Procedure : -
  • Balloon Diameter (mm) : 16
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 8
  • Model : AT75166
  • Procedure : -
  • Balloon Diameter (mm) : 16
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 8
  • Model : AT120182
  • Procedure : -
  • Balloon Diameter (mm) : 18
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 8
  • Model : AT75184
  • Procedure : -
  • Balloon Diameter (mm) : 18
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 8
  • Model : AT120184
  • Procedure : -
  • Balloon Diameter (mm) : 18
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 8
  • Model : AT75186
  • Procedure : -
  • Balloon Diameter (mm) : 18
  • Balloon Length (cm) : 6
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 9
  • Model : AT75202
  • Procedure : -
  • Balloon Diameter (mm) : 20
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 9
  • Model : AT120202
  • Procedure : -
  • Balloon Diameter (mm) : 20
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 9
  • Model : AT75204
  • Procedure : -
  • Balloon Diameter (mm) : 20
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 9
  • Model : AT120204
  • Procedure : -
  • Balloon Diameter (mm) : 20
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 9
  • Model : AT75222
  • Procedure : -
  • Balloon Diameter (mm) : 22
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 4
  • Rated Burst Pressure (atm) : 14
  • Sheath Size (F) : 10
  • Model : AT75224
  • Procedure : -
  • Balloon Diameter (mm) : 22
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 4
  • Rated Burst Pressure (atm) : 14
  • Sheath Size (F) : 10
  • Model : AT75242
  • Procedure : -
  • Balloon Diameter (mm) : 24
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 4
  • Rated Burst Pressure (atm) : 14
  • Sheath Size (F) : 10
  • Model : AT75244
  • Procedure : -
  • Balloon Diameter (mm) : 24
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 4
  • Rated Burst Pressure (atm) : 14
  • Sheath Size (F) : 10
  • Model : AT75262
  • Procedure : -
  • Balloon Diameter (mm) : 26
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 4
  • Rated Burst Pressure (atm) : 12
  • Sheath Size (F) : 12
  • Model : AT75264
  • Procedure : -
  • Balloon Diameter (mm) : 26
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 75
  • Nominal Pressure (atm) : 4
  • Rated Burst Pressure (atm) : 12
  • Sheath Size (F) : 12

Questions & Answers