Manufacturer > BD > Devices > Atlas™ Gold

Atlas™ Gold

Device-Type

PTA Ballons

Targated Speciality

Angioplasty

Manufacturer

BD

Used in Procedure

Angioplasty


The Atlas Gold PTA Dilatation Catheter is a high performance balloon catheter consisting of an over-thewire catheter with a balloon fixed at the distal tip. The proprietary non-compliant, low profile balloon is designed to provide consistent balloon diameters and lengths even at high pressures. Two radiopaque markers delineate the working length of the balloon and aid in balloon placement. The coaxial catheter includes a tapered atraumatic tip to facilitate advancement of the catheter to and through the stenosis. The proximal portion of the catheter includes a female luer lock hub connected to the inflation lumen, and a female luer-lock hub connected to the guidewire lumen. The over-the-wire catheter is compatible with .035" guidewire and is available in 80cm and 120cm working lengths.

Packaged with every product is a profile reducing sheath that is positioned over the balloon for protection before use. A re-wrapping tool is also provided on the catheter shaft to aid in re-wrap/refolding of the balloon. This product is not manufactured with any natural rubber latex.

Features and Benefits

  • Large balloon diameters up to 26mm
  • Ultra non-compliant technology offers virtually no growth past stated diameter*
  • Tapered tip to facilitate trackability
  • Delivers maximum force to areas of most resistance (up to 18 ATM)
  • Short shoulders designed to minimize vessel straightening and allow for high pressure post-dilation at stent edges
  • Indicated for use in the peripheral vasculature, including the iliac arteries, iliac and femoral veins, and native or synthetic arteriovenous dialysis fistulae (see product IFU)

Safety informations

Indications for Use

Atlas Gold PTA Dilatation Catheter is indicated for use in Percutaneous Transluminal Angioplasty of the peripheral vasculature, including the iliac arteries and iliac and femoral veins, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for post-dilatation of stents and stent grafts in the peripheral vasculature. This catheter is not for use in coronary arteries.


Contraindications

None known. 


Warnings

1. Contents supplied STERILE using ethylene oxide (EO). Non-Pyrogenic. Do not use if sterile barrier is opened or damaged. Single patient use only. Do not reuse, reprocess, or re-sterilize.

2. This device has been designed for single use only. Reusing this medical device bears the risk of cross-patient contamination as medical devices – particularly those with long and small lumina, joints, and/or crevices between components – are difficult or impossible to clean once body fluids or tissues with potential pyrogenic or microbial contamination have had contact with the medical device for an indeterminable period of time. The residue of biological material can promote the contamination of the device with pyrogens or microorganisms which may lead to infectious complications.

3. Do not resterilize. After resterilization, the sterility of the product is not guaranteed because of an indeterminable degree of potential pyrogenic or microbial contamination which may lead to infectious complications. Cleaning, reprocessing, and/or resterilization of the present medical device increases the probability that the device will malfunction due to potential adverse effects on components that are influenced by thermal and/or mechanical changes.

4. To reduce the potential for vessel damage, the inflated diameter and length of the balloon should approximate the diameter and length of the vessel just proximal and distal to the stenosis.

5. To reduce the potential for stent or stent graft damage and/or vessel damage from the stent or stent graft, the diameter of the balloon should be no greater than the diameter of the stent or stent graft. Refer to the stent or stent graft IFU for safety information including the WARNINGS, PRECAUTIONS, and potential ADVERSE EFFECTS regarding the use of balloon post-dilatation.

6. When the catheter is exposed to the vascular system, it should be manipulated while under high-quality fluoroscopic observation. Do not advance or retract the catheter unless the balloon is fully deflated. If resistance is met during manipulation, determine the cause of the resistance before proceeding. Applying excessive force to the catheter can result in tip breakage or balloon separation.

7. Do not exceed the RBP recommended for this device. Balloon rupture may occur if the RBP rating is exceeded. To prevent over pressurization,use of a pressure monitoring device is recommended.

8. After use, this product may be a potential biohazard. Handle and dispose of in accordance with acceptable medical practices and applicable local, state, and federal laws and regulations.


Precautions

1. Carefully inspect the catheter prior to use to verify that catheter has not been damaged during shipment and that its size, shape, and condition are suitable for the procedure for which it is to be used. Do not use if product damage is evident.

2. The Atlas Gold Catheter shall only be used by physicians trained in the performance of Percutaneous Transluminal Angioplasty.

3. The minimal acceptable sheath French size is printed on the package label. Do not attempt to pass the PTA catheter through a smaller size sheath introducer than indicated on the label.

4. Do not remove the guidewire in situ to shoot contrast through the wire lumen or perform a wire exchange. If the wire is removed while the balloon catheter is situated in tortuous anatomy, the risk of kinking the catheter is increased.

5. Use the recommended balloon inflation medium (a range of 30-50% contrast medium / a range of 50-70% sterile saline solution). It has been shown that a 30/70% contrast/saline ratio has yielded faster balloon inflation / deflation times.

6. Never use air or other gaseous medium to inflate the balloon.

7. If resistance is felt during post procedure withdrawal of the catheter through the introducer sheath, determine if contrast is trapped in the balloon with fluoroscopy. If contrast is present, push the balloon out of the sheath and then completely evacuate the contrast before proceeding to withdraw the balloon.

8. If resistance is still felt during post procedure withdrawal of the catheter, it is recommended to remove the balloon catheter and guidewire/introducer sheath as a single unit.

9. Do not continue to use the balloon catheter if the shaft has been bent or kinked.

10. Prior to re-insertion through the introducer sheath, the balloon should be wiped clean with gauze, rinsed with sterile normal saline, and refolded with the balloon re-wrap tool. Balloon re-wrapping should only occur while the balloon catheter is supported with a guidewire

Potential adverse events

The complications which may result from a peripheral balloon dilatation procedure include:

• Acute thrombotic occlusion • Additional intervention • Allergic reaction to drugs or contrast medium • Aneurysm or pseudoaneurysm • Arrhythmias • Balloon rupture • Balloon getting stuck on stent • Distal embolization (PE) • Hematoma • Hemorrhage, including bleeding at the puncture site • Hypotension/hypertension • Inflammation • Leg edema • Occlusion • Pain or tenderness • Pneumothorax or hemothorax • Sepsis/infection • Shock • Short term hemodynamic deterioration • Stent disruption or dislodgement with balloon insertion • Stroke • Thrombosis • Vessel dissection, perforation, rupture, or spasm 

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Balloon Diameter (mm) Balloon Length (cm) Shaft Length (cm) Nominal Pressure (atm) Rated Burst Pressure (atm) Sheath Size (F)
Atlas™ Gold PTA Dilatation Catheter
ATG80122 12 2 80 6 18 7
Atlas™ Gold PTA Dilatation Catheter
ATG120122 12 2 120 6 18 7
Atlas™ Gold PTA Dilatation Catheter
ATG80124 12 4 80 6 18 7
Atlas™ Gold PTA Dilatation Catheter
ATG120124 12 4 120 6 18 7
Atlas™ Gold PTA Dilatation Catheter
ATG80126 12 6 80 6 18 7
Atlas™ Gold PTA Dilatation Catheter
ATG120126 12 6 120 6 18 7
Atlas™ Gold PTA Dilatation Catheter
ATG80142 14 2 80 6 18 7
Atlas™ Gold PTA Dilatation Catheter
ATG120142 14 2 120 6 18 7
Atlas™ Gold PTA Dilatation Catheter
ATG80144 14 4 80 6 18 7
Atlas™ Gold PTA Dilatation Catheter
ATG120144 14 4 120 6 18 7
Atlas™ Gold PTA Dilatation Catheter
ATG80146 14 6 80 6 18 7
Atlas™ Gold PTA Dilatation Catheter
ATG120146 14 6 120 6 18 7
Atlas™ Gold PTA Dilatation Catheter
ATG80162 16 2 80 6 18 8
Atlas™ Gold PTA Dilatation Catheter
ATG120162 16 2 120 6 18 8
Atlas™ Gold PTA Dilatation Catheter
ATG80164 16 4 80 6 18 8
Atlas™ Gold PTA Dilatation Catheter
ATG120164 16 4 120 6 18 8
Atlas™ Gold PTA Dilatation Catheter
ATG80166 16 6 80 6 16 8
Atlas™ Gold PTA Dilatation Catheter
ATG120166 16 6 120 6 16 8
Atlas™ Gold PTA Dilatation Catheter
ATG80182 18 2 80 6 16 8
Atlas™ Gold PTA Dilatation Catheter
ATG120182 18 2 120 6 16 8
Atlas™ Gold PTA Dilatation Catheter
ATG80184 18 4 80 6 16 8
Atlas™ Gold PTA Dilatation Catheter
ATG120184 18 4 120 6 16 8
Atlas™ Gold PTA Dilatation Catheter
ATG80186 18 6 80 6 16 9
Atlas™ Gold PTA Dilatation Catheter
ATG120186 18 6 120 6 16 9
Atlas™ Gold PTA Dilatation Catheter
ATG80202 20 2 80 6 16 9
Atlas™ Gold PTA Dilatation Catheter
ATG120202 20 2 120 6 16 9
Atlas™ Gold PTA Dilatation Catheter
ATG80204 20 4 80 6 16 9
Atlas™ Gold PTA Dilatation Catheter
ATG120204 20 4 120 6 16 9
Atlas™ Gold PTA Dilatation Catheter
ATG80222 22 2 80 4 14 10
Atlas™ Gold PTA Dilatation Catheter
ATG120222 22 2 120 4 14 10
Atlas™ Gold PTA Dilatation Catheter
ATG120264 26 4 120 4 12 12
Atlas™ Gold PTA Dilatation Catheter
ATG120224 22 4 120 4 14 10
  • Model : ATG80122
  • Procedure : -
  • Balloon Diameter (mm) : 12
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : ATG120122
  • Procedure : -
  • Balloon Diameter (mm) : 12
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : ATG80124
  • Procedure : -
  • Balloon Diameter (mm) : 12
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : ATG120124
  • Procedure : -
  • Balloon Diameter (mm) : 12
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : ATG80126
  • Procedure : -
  • Balloon Diameter (mm) : 12
  • Balloon Length (cm) : 6
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : ATG120126
  • Procedure : -
  • Balloon Diameter (mm) : 12
  • Balloon Length (cm) : 6
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : ATG80142
  • Procedure : -
  • Balloon Diameter (mm) : 14
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : ATG120142
  • Procedure : -
  • Balloon Diameter (mm) : 14
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : ATG80144
  • Procedure : -
  • Balloon Diameter (mm) : 14
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : ATG120144
  • Procedure : -
  • Balloon Diameter (mm) : 14
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : ATG80146
  • Procedure : -
  • Balloon Diameter (mm) : 14
  • Balloon Length (cm) : 6
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : ATG120146
  • Procedure : -
  • Balloon Diameter (mm) : 14
  • Balloon Length (cm) : 6
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 7
  • Model : ATG80162
  • Procedure : -
  • Balloon Diameter (mm) : 16
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 8
  • Model : ATG120162
  • Procedure : -
  • Balloon Diameter (mm) : 16
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 8
  • Model : ATG80164
  • Procedure : -
  • Balloon Diameter (mm) : 16
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 8
  • Model : ATG120164
  • Procedure : -
  • Balloon Diameter (mm) : 16
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 18
  • Sheath Size (F) : 8
  • Model : ATG80166
  • Procedure : -
  • Balloon Diameter (mm) : 16
  • Balloon Length (cm) : 6
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 8
  • Model : ATG120166
  • Procedure : -
  • Balloon Diameter (mm) : 16
  • Balloon Length (cm) : 6
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 8
  • Model : ATG80182
  • Procedure : -
  • Balloon Diameter (mm) : 18
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 8
  • Model : ATG120182
  • Procedure : -
  • Balloon Diameter (mm) : 18
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 8
  • Model : ATG80184
  • Procedure : -
  • Balloon Diameter (mm) : 18
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 8
  • Model : ATG120184
  • Procedure : -
  • Balloon Diameter (mm) : 18
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 8
  • Model : ATG80186
  • Procedure : -
  • Balloon Diameter (mm) : 18
  • Balloon Length (cm) : 6
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 9
  • Model : ATG120186
  • Procedure : -
  • Balloon Diameter (mm) : 18
  • Balloon Length (cm) : 6
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 9
  • Model : ATG80202
  • Procedure : -
  • Balloon Diameter (mm) : 20
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 9
  • Model : ATG120202
  • Procedure : -
  • Balloon Diameter (mm) : 20
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 9
  • Model : ATG80204
  • Procedure : -
  • Balloon Diameter (mm) : 20
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 9
  • Model : ATG120204
  • Procedure : -
  • Balloon Diameter (mm) : 20
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 6
  • Rated Burst Pressure (atm) : 16
  • Sheath Size (F) : 9
  • Model : ATG80222
  • Procedure : -
  • Balloon Diameter (mm) : 22
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 80
  • Nominal Pressure (atm) : 4
  • Rated Burst Pressure (atm) : 14
  • Sheath Size (F) : 10
  • Model : ATG120222
  • Procedure : -
  • Balloon Diameter (mm) : 22
  • Balloon Length (cm) : 2
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 4
  • Rated Burst Pressure (atm) : 14
  • Sheath Size (F) : 10
  • Model : ATG120264
  • Procedure : -
  • Balloon Diameter (mm) : 26
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 4
  • Rated Burst Pressure (atm) : 12
  • Sheath Size (F) : 12
  • Model : ATG120224
  • Procedure : -
  • Balloon Diameter (mm) : 22
  • Balloon Length (cm) : 4
  • Shaft Length (cm) : 120
  • Nominal Pressure (atm) : 4
  • Rated Burst Pressure (atm) : 14
  • Sheath Size (F) : 10