AVIGO™ 0.014" Hydrophilic Guidewire

Device-Type

Hydrophilic Guidewires

Targated Speciality

Endovascular

Manufacturer

Medtronic


The Avigo™ hydrophilic guidewire provides support for tracking, crossing and maintaining catheter stability. Learn more about its Twister™ technology and MicroRidge™ technology here. 


CHARACTERISTICS

  • Platinum coil radiopaque marker
  • Tungsten-doped radiopaque jacket with hydrophilic coating: 38cm
  • Reshapeable tip: 2cm
  • PTFE cover
  • Stainless steel core wire


Features and Benefits

THE SUPPORT YOU NEED


TRACKING

The Avígo™ guidewire provides support for tracking 021 and 027 systems smoothly.

CROSSING

Increased tip buckling strength to cross challenge clots.

MAINTAINING

The Avígo™ guidewire’s core wire design provides support for maintaining catheter stability during precise navigation.



TECHNOLOGIES TO IMPROVE THE WIRE


TWISTER™ TECHNOLOGY

The core wire is twisted and annealed to improve torque.


MICRORIDGE™ TECHNOLOGY

The distal tip is designed to minimise prolapse, enhance proximal push forces, and provide distal tip support.

Use Case Examples

The Hydrophilic Guidewire is indicated for general intravascular use to aid in the selective placement of catheters in the peripheral and cerebral vasculature during diagnostic and/or therapeutic procedures. The device is not intended for use in the coronary arteries.


The Guidewire Torque Device is intended to facilitate guidewire manipulation during interventional procedures. The Guidewire Introducer is intended to facilitate guidewire insertion into a catheter hub or through a hemostasis valve.

Safety informations

WARNINGS

• This device is intended for single use only. Discard the product after use. Structural integrity and/or function may be impaired through reuse or cleaning. • Never advance or withdraw the guidewire against resistance until the cause of the resistance is determined by fluoroscopy. Do not attempt to move the guidewire without observing the resultant tip response


PRECAUTIONS

• Prior to use, carefully examine the guidewire and its packaging to verify no damage has occurred during shipment. Do not use if pouch is open or damaged. • Inspect the guidewire for any surface irregularities, bends or kinks. Any guidewire damage may decrease the desired performance characteristics. Avoid exposure of the guidewire coating to disinfection agents such as alcohols. This may result in coating delamination. • The hydrophilic coating bonded to the guidewire is an extremely lubricious surface when properly hydrated. Ensure proper hydration by allowing entire guidewire to become wet for at least 30 seconds prior to use. • Neither the guidewire introducer nor the torque device is intended to enter the body. • To prevent damage to the guidewire coating, manipulate the guidewire using the torque device at proximal end of the guidewire.

Potential adverse events

Procedures requiring percutaneous catheter introduction should not be attempted by physicians unfamiliar with the possible complications, which may occur during or after the procedure. Possible complications include, but are not limited, to the following:

• Perforation of vessel or arterial wall

• Thrombus formation

• Puncture site hematoma

• Vasospasm

• Infection

• Ischemia 

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Diameter (in) Total Length (cm) Coil Length (cm) Tip Shape
AVIGO™ 0.014"
103-0606-200 0.014 205 5 Straight
device-thumbnail
AVIGO™ 0.014"
  • Model : 103-0606-200
  • Procedure : -
  • Diameter (in) : 0.014
  • Total Length (cm) : 205
  • Coil Length (cm) : 5
  • Tip Shape : Straight