AXS Catalyst™ Distal Access Catheter

Device-Type

Aspiration Catheter

Manufacturer

Stryker Neurovascular


The CAT™ 5 Distal Access Catheter provides easy navigation and reliable support for distal access cases.


The AXS Catalyst Distal Access Catheter is a single lumen, variable stiffness catheter designed for use in facilitating the insertion and guidance of appropriately sized interventional devices into the peripheral and neuro vascular system. The catheter shaft has a hydrophilic coating to reduce friction during use. The catheter includes a radiopaque marker on the distal end for angiographic visualization and a luer hub on the proximal end allowing attachments for flushing and aspiration. It is packaged with a Rotating Hemostastic Valve (RHV) and Tuohy Borst valve with sideport for flushing, insertion of catheters and aspiration. The peel away introducer sheaths are designed to protect the distal tip of the catheter during insertion into the RHV or Tuohy Borst. 

Features and Benefits

Image of Excellent trackability<sup>1</sup>

Excellent trackability1

The 5cm distal flexible zone combined with a highly supportive proximal shaft for pushability leads to the smooth tracking design.1

Image of Stable delivery

Stable delivery

Gain stable distal support without sacrificing trackability.1

Image of Atraumatic access

Atraumatic access

The rounded tip and flexible distal zone on the CAT 5 Distal Access Catheter is designed for confident advancement into fragile distal vessels.

Image of Go distal!

Go distal!

The design of the CAT 5 Distal Access Catheter is designed for closer placement to the treatment site. Focus on the intervention, not access challenges.

Safety informations

warning

Contents supplied STERILE using an ethylene oxide (EO) process. Do not use if sterile barrier is damaged. If damage is found, call your Stryker Neurovascular representative. For single use only. Do not reuse, reprocess or resterilize. Reuse, reprocessing or resterilization may compromise the structural integrity of the device and/or lead to device failure which, in turn, may result in patient injury, illness or death. Reuse, reprocessing or resterilization may also create a risk of contamination of the device and/or cause patient infection or cross-infection, including, but not limited to, the transmission of infectious disease(s) from one patient to another. Contamination of the device may lead to injury, illness or death of the patient.


contraindications

None known.


PRECautions

• Carefully inspect all devices prior to use. Verify size, length, and condition are suitable for the specific procedure. Do not use a device that has been damaged in any way. Damaged device may cause complications.

• To control the proper introduction, movement, positioning and removal of the catheter within the vascular system, users should employ standard clinical angiographic and fluoroscopic practices and techniques throughout the interventional procedure.

• Use the product prior to the “Use By” date printed on the label.

• To prevent thrombus formation and contrast media crystal formation, maintain a constant infusion of appropriate flush solution through catheter lumen. • Torquing the catheter may cause d

Potential adverse events

Potential adverse events associated with the use of catheters or with the endovascular procedures include, but are not limited to:

• Access site complications

• Allergic reaction

• Aneurysm perforation

• Aneurysm rupture

• Death

• Embolism (air, foreign body, plaque, thrombus)

• Hematoma

• Hemorrhage

• Infection

• Ischemia

• Neurological deficits

• Pseudoaneurysm

• Stroke

• Transient Ischemic Attack

• Vasospasm

• Vessel dissection

• Vessel occlusion

• Vessel perforation

• Vessel rupture

• Vessel thrombosis

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Inner Diameter Distal OD Proximal OD Effective length Distal flex segment
AXS Catalyst™ 5 Distal Access Catheter
M003IC0581150 0.058in (1.47mm) 5.3F (1.76mm) 5.6F (1.86mm) 115cm 5cm
  • Model : M003IC0581150
  • Procedure : -
  • Inner Diameter : 0.058in (1.47mm)
  • Distal OD : 5.3F (1.76mm)
  • Proximal OD : 5.6F (1.86mm)
  • Effective length : 115cm
  • Distal flex segment : 5cm