Manufacturer > Terumo Interventional Systems > Devices > AZUR® Framing Coil System

AZUR® Framing Coil System

Device-Type

Embolization Coil

Used in Procedure

Embolization


The Detachable Azur Peripheral Coil System Framing Coil (Azur system) consists of a coil implant attached to a delivery system. The coils are platinum coils. The delivery pusher is powered by an Azur Detachment Controller to selectively detach the coils. The Azur Detachment Controller is provided separately.


The Azur system is available in a broad range of coil diameters and lengths. The coil must be delivered only through a wire-reinforced microcatheter with the minimum inner diameter specified. 


Features and Benefits

ENHANCE STABILITY FROM THE START


A THREE-DIMENSIONAL APPROACH TO ANEURYSMS

Provides an even distribution of coil loops at the treatment site

  • Designed to provide greater coverage1
  • Conforms to diverse morphologies1
  • Available in .018” and 035” systems

Use Case Examples

The Azur system is intended to reduce or block the rate of blood flow in vessels of the peripheral vasculature. It is intended for use in the interventional radiologic management of arteriovenous malformations, arteriovenous fistulae, aneurysms, and other lesions of the peripheral vasculature. This device should only be used by physicians who have undergone training in the use of the Azur system for embolization procedures as prescribed by a representative from Terumo or a Terumo-authorized distributor. 

Safety informations

CONTRAINDICATIONS

Use of the Azur system is contraindicated in any of the following circumstances:

• When superselective coil placement is not possible.

• When end arteries lead directly to nerves.

• When arteries supplying the lesion to be treated are not large enough to accept emboli.

• When the A-V shunt is larger than the coil.

• In the presence of severe atheromatous disease.

• In the presence of vasospasm (or likely onset of vasospasm). 

Potential adverse events

Potential complications include, but are not limited to: hematoma at the site of entry, vessel/aneurysm perforation, unintended parent artery occlusion, incomplete filling, vascular thrombosis, hemorrhage, ischemia, vasospasm, edema, coil migration or misplacement, premature or difficult coil detachment, clot formation. revascularization, post-embolization syndrome, and neurological deficits including stroke and possibly death. The physician should be aware of these complications and instruct patients when indicated. Appropriate patient management should be considered. 

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Description 1/BX LOOP DIAMETER (mm) LENGTH (cm) NUMBER OF LOOPS OD (in) VOLUME (mm3 )
AZUR Framing Coils .018"
45-680820 AZUR 18D Framing 8 mm x 20 cm 8 20 6 0.014 19.86
AZUR Framing Coils .018"
45-681434 AZUR 18D Framing 14 mm x 34 cm 14 34 6 0.015 38.76
AZUR Framing Coils .018"
45-682050 AZUR 18D Framing 20 mm x 50 cm 20 50 6 0.015 57.00
AZUR Framing Coils .018"
45-681026 AZUR 18D Framing 10 mm x 26 cm 10 26 6 0.014 25.82
AZUR Framing Coils .035"
45-650820 AZUR 35D Framing 8 mm x 20 cm 8 20 6 0.022 49.05
AZUR Framing Coils .035"
45-651026 AZUR 35D Framing 10 mm x 26 cm 10 26 6 0.022 63.76
AZUR Framing Coils .035"
45-651434 AZUR 35D Framing 14 mm x 34 cm 14 34 6 0.022 83.38
AZUR Framing Coils .035"
45-652050 AZUR 35D Framing 20 mm x 50 cm 20 50 6 0.022 122.62
  • Model : 45-680820
  • Procedure : -
  • Description 1/BX : AZUR 18D Framing 8 mm x 20 cm
  • LOOP DIAMETER (mm) : 8
  • LENGTH (cm) : 20
  • NUMBER OF LOOPS : 6
  • OD (in) : 0.014
  • VOLUME (mm3 ) : 19.86
  • Model : 45-681434
  • Procedure : -
  • Description 1/BX : AZUR 18D Framing 14 mm x 34 cm
  • LOOP DIAMETER (mm) : 14
  • LENGTH (cm) : 34
  • NUMBER OF LOOPS : 6
  • OD (in) : 0.015
  • VOLUME (mm3 ) : 38.76
  • Model : 45-682050
  • Procedure : -
  • Description 1/BX : AZUR 18D Framing 20 mm x 50 cm
  • LOOP DIAMETER (mm) : 20
  • LENGTH (cm) : 50
  • NUMBER OF LOOPS : 6
  • OD (in) : 0.015
  • VOLUME (mm3 ) : 57.00
  • Model : 45-681026
  • Procedure : -
  • Description 1/BX : AZUR 18D Framing 10 mm x 26 cm
  • LOOP DIAMETER (mm) : 10
  • LENGTH (cm) : 26
  • NUMBER OF LOOPS : 6
  • OD (in) : 0.014
  • VOLUME (mm3 ) : 25.82
  • Model : 45-650820
  • Procedure : -
  • Description 1/BX : AZUR 35D Framing 8 mm x 20 cm
  • LOOP DIAMETER (mm) : 8
  • LENGTH (cm) : 20
  • NUMBER OF LOOPS : 6
  • OD (in) : 0.022
  • VOLUME (mm3 ) : 49.05
  • Model : 45-651026
  • Procedure : -
  • Description 1/BX : AZUR 35D Framing 10 mm x 26 cm
  • LOOP DIAMETER (mm) : 10
  • LENGTH (cm) : 26
  • NUMBER OF LOOPS : 6
  • OD (in) : 0.022
  • VOLUME (mm3 ) : 63.76
  • Model : 45-651434
  • Procedure : -
  • Description 1/BX : AZUR 35D Framing 14 mm x 34 cm
  • LOOP DIAMETER (mm) : 14
  • LENGTH (cm) : 34
  • NUMBER OF LOOPS : 6
  • OD (in) : 0.022
  • VOLUME (mm3 ) : 83.38
  • Model : 45-652050
  • Procedure : -
  • Description 1/BX : AZUR 35D Framing 20 mm x 50 cm
  • LOOP DIAMETER (mm) : 20
  • LENGTH (cm) : 50
  • NUMBER OF LOOPS : 6
  • OD (in) : 0.022
  • VOLUME (mm3 ) : 122.62