CENTEZE® CENTESIS CATHETER

Device-Type

Drainage Catheters

Targated Speciality

Cardiovascular


The Centeze® centesis catheter (Centeze®) is an over-the needle catheter for percutaneous aspiration and small volume drainages for durations not to exceed 24 hours. Each Centeze® includes the following components: Catheter with three distal sideholes, percutaneous entry needle and porous plug.

Features and Benefits

Corp. Centeze® was designed to enhance ease in every centesis procedure.

  • 3 large skived holes to aid in maximum drainage and reduction of clogging.
  • Tapered tip, smooth transition, and siliconized catheter to aid in insertion.
  • Echogenic needle with bevel indicator to aid in visibility.
  • Clear needle hub for flashback confirmation.


Safety informations

INTENDED USE AND PATIENT POPULATION

The Centeze® is intended for use in percutaneous fluid aspirations and small volume drainage procedures. For use on both adult and adolescent groups.

CONTRAINDICATIONS

  • Where percutaneous drainage catheterization is unacceptable
  • Bleeding diathesis and uncontrolled hypertension
  • Anticoagulant use
  • Chemical ablation of tissue

WARNINGS

• The Centeze® is supplied sterile for single use only.

• Do not exceed insertion dwell time of 24 hours.

• Do not alter this device in any way.

• Do not resterilize the device. Re-sterilization could change the physical characteristics of the materials and should not be attempted.

• Do not reuse the device. Reuse will result in increased biocontamination risk for the patient resulting in infection or pyrogenic response.

• During insertion avoid contact with bone, cartilage and scar tissue, which can damage the needle and catheter tip.

PRECAUTIONS

The Centeze® deployment procedure should be performed by physicians thoroughly trained in drainage techniques and procedures.

Do not use the Centeze® if the packaging is damaged.

Inspect the Centeze® prior to use for any bends or kinks. Do not use a damaged needle because trauma to the patient and/or inability to place the drainage catheter may occur. Any serious incident in relation to this device should be reported to the manufacturer and the competent authority established in the user and/or patient’s Member State. COMPLICATIONS: These are generally associated with drainag

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Size(F) Length (cm) Needle gauge Needle Tip Lock Needle Length
Centeze Centesis Catheter
DRC-002-01 4 7 21 Echogenic Slip fit 9
Centeze Centesis Catheter
DRC-002-04 4 10 21 Echogenic Slip fit 12
Centeze Centesis Catheter
DRC-002-02 5 7 19 Echogenic Slip fit 9
Centeze Centesis Catheter
DRC-002-05 5 10 19 Echogenic Slip fit 12
Centeze Centesis Catheter
DRC-002-08 5 15 19 Echogenic Slip fit 17
Centeze Centesis Catheter
DRC-002-06 6 10 18 Echogenic Slip fit 12
  • Model : DRC-002-01
  • Procedure : -
  • Size(F) : 4
  • Length (cm) : 7
  • Needle gauge : 21
  • Needle Tip : Echogenic
  • Lock : Slip fit
  • Needle Length : 9
  • Model : DRC-002-04
  • Procedure : -
  • Size(F) : 4
  • Length (cm) : 10
  • Needle gauge : 21
  • Needle Tip : Echogenic
  • Lock : Slip fit
  • Needle Length : 12
  • Model : DRC-002-02
  • Procedure : -
  • Size(F) : 5
  • Length (cm) : 7
  • Needle gauge : 19
  • Needle Tip : Echogenic
  • Lock : Slip fit
  • Needle Length : 9
  • Model : DRC-002-05
  • Procedure : -
  • Size(F) : 5
  • Length (cm) : 10
  • Needle gauge : 19
  • Needle Tip : Echogenic
  • Lock : Slip fit
  • Needle Length : 12
  • Model : DRC-002-08
  • Procedure : -
  • Size(F) : 5
  • Length (cm) : 15
  • Needle gauge : 19
  • Needle Tip : Echogenic
  • Lock : Slip fit
  • Needle Length : 17
  • Model : DRC-002-06
  • Procedure : -
  • Size(F) : 6
  • Length (cm) : 10
  • Needle gauge : 18
  • Needle Tip : Echogenic
  • Lock : Slip fit
  • Needle Length : 12