Manufacturer > BD > Devices > Conquest™ 40 PTA Dilatation Catheters

Conquest™ 40 PTA Dilatation Catheters

Device-Type

PTA Ballons

Manufacturer

BD


The Conquest® 40 PTA Dilatation Catheter is a high performance balloon catheter consisting of an over-the-wire catheter with a balloon fixed at the distal tip. The proprietary ultra non-compliant, low profile balloon is designed to provide consistent balloon diameters and lengths even at high pressures. Two radiopaque markers delineate the working length of the balloon and aid in balloon placement. The coaxial catheter includes a tapered atraumatic tip to facilitate advancement of the catheter to and through the stenosis. The proximal portion of the catheter includes a female luer lock hub connected to the inflation lumen, and a female luer-lock hub connected to the guidewire lumen. The over-the-wire catheter is compatible with 0.035" guidewires and is available in 50cm and 75cm working lengths. Packaged with every product is a profile reducing sheath that is positioned over the balloon for protection before use. A re-wrapping tool is also provided on the catheter shaft. A stylet is placed into the tip of the catheter to aid in balloon rewrap/refolding of the balloon.

Features and Benefits

  • Strength that reaches high atmospheres
  • Incomparably ultra non-compliant
  • Delivers maximum dilatation forces to areas of most resistance
  • True to size 8 ATM to 40 ATM – Allows high pressures without vessel over expansion
  • Advancements in delivery
  • Offers tapered tip
  • Sizes available in 4-12 mm diameters and 20 - 100 mm lengths
  • Labeled for syringe inflation


Safety informations

Indications for Use:

Conquest® 40 PTA Dilatation Catheter is recommended for use in Percutaneous Transluminal Angioplasty of the femoral, iliac, and renal arteries and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also recommended for post-dilatation of stents and stent grafts in the peripheral vasculature. This catheter is not for use in coronary arteries.


Contraindications:

None known.


Warnings:

1.) Contents supplied STERILE using ethylene oxide (EO). Non-Pyrogenic. Do not use if sterile barrier is opened or damaged. Single patient use only. Do not reuse, reprocess or re-sterilize.

2.) This device has been designed for single use only. Reusing this medical device bears the risk of cross-patient contamination as medical devices – particularly those with long and small lumina, joints, and/or crevices between components – are difficult or impossible to clean once body fluids or tissues with potential pyrogenic or microbial contamination have had contact with the medical device for an indeterminable period of time. The residue of biological material can promote the contamination of the device with pyrogens or microorganisms which may lead to infectious complications.

3.) Do not resterilize. After resterilization, the sterility of the product is not guaranteed because of an indeterminable degree of potential pyrogenic or microbial contamination which may lead to infectious complications. Cleaning, reprocessing and/or resterilization of the present medical device increases the probability that the device will malfunction due to potential adverse effects on components that are influenced by thermal and/or mechanical changes.

4.) To reduce the potential for vessel damage, the inflated diameter and length of the balloon should approximate the diameter and length of the vessel just proximal and distal to the stenosis.

5.) To reduce the potential for stent or stent graft damage and/or vessel damage from the stent or stent graft, the diameter of the balloon should be no greater than the diameter of the stent or stent graft. Refer to the stent or stent graft IFU for safety information including the WARNINGS, PRECAUTIONS and potential ADVERSE EFFECTS regarding the use of balloon post-dilatation.

6.) When the catheter is exposed to the vascular system, it should be manipulated while under high-quality fluoroscopic observation. Do not advance or retract the catheter unless the balloon is fully deflated. If resistance is met during manipulation, determine the cause of the resistance before proceeding. Applying excessive force to the catheter can result in tip breakage or balloon separation.

7.) Do not exceed the RBP recommended for this device. Balloon rupture may occur if the RBP rating is exceeded. To prevent over pressurization, use of a pressure monitoring device is recommended or the use of indicated syringes.

8.) After use, this product may be a potential biohazard. Handle and dispose of in accordance with acceptable medical practices and applicable local, state and federal laws and regulations.


Precautions:

1.) Carefully inspect the catheter prior to use to verify that catheter has not been damaged during shipment and that its size, shape and condition are suitable for the procedure for which it is to be used. Do not use if product damage is evident.

2.) The Conquest® 40 catheter shall only be used by physicians trained in the performance of percutaneous transluminal angioplasty.

3.) The minimal acceptable sheath French size is printed on the package label. Do not attempt to pass the PTA catheter through a smaller size sheath introducer than indicated on the label.

4.) Do not remove the guidewire in situ to shoot contrast through the wire lumen or perform a wire exchange. If the wire is removed while the balloon catheter is situated in tortuous anatomy, the risk of kinking the catheter is increased.

5.) Use the recommended balloon inflation medium (a range of 30-50% contrast medium/a range of 50-70% sterile saline solution). It has been shown that a 30/70% contrast / saline ratio has yielded faster balloon inflation / deflation times. 6.) Never use air or other gaseous medium to inflate the balloon.

7.) If resistance is felt during post procedure withdrawal of the catheter through the introducer sheath, determine if contrast is trapped in the balloon with fluoroscopy. If contrast is present, push the balloon out of the sheath and then completely evacuate the contrast before proceeding to withdraw the balloon.

8.) If resistance is still felt during post procedure withdrawal of the catheter, it is recommended to remove the balloon catheter and guidewire/introducer sheath as a single unit.

9.) Do not continue to use the balloon catheter if the shaft has been bent or kinked.

10.) Prior to re-insertion through the introducer sheath, the balloon should be wiped clean with gauze, rinsed with sterile normal saline, and refolded with the balloon re-wrap tool. Balloon re-wrapping should only occur 

Potential adverse events

The complications which may result from a peripheral balloon dilatation procedure include: Additional intervention • Allergic reaction to drugs or contrast medium • Aneurysm or pseudoaneurysm • Arrhythmias • Embolization • Hematoma • Hemorrhage, including bleeding at the puncture site • Hypotension/hypertension • Inflammation • Occlusion • Pain or tenderness • Pneumothorax or hemothorax • Sepsis/infection • Shock • Short term hemodynamic deterioration • Thrombosis • Vessel dissection, perforation, rupture, or spasm.

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Shaft Lengths(cm) Diameter(mm) Length(cm) Syringe Inflation(cc) RBP(ATM) Nominal Pressure(atm) Sheath Size (F) Guidewire
Conquest 40 PTA Dilatation Catheters
CQF5042 50 4 2 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5044 50 4 4 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5046 50 4 6 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5048 50 4 8 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF50410 50 4 10 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5052 50 5 2 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5054 50 5 4 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5056 50 5 6 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5058 50 5 8 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF50510 50 5 10 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5062 50 6 2 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5064 50 6 4 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5066 50 6 6 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5068 50 6 8 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF50610 50 6 10 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5072 50 7 2 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5074 50 7 4 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5076 50 7 6 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5078 50 7 8 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF50710 50 7 10 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5082 50 8 2 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5083 50 8 3 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5084 50 8 4 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5086 50 8 6 ≥3 35 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5088 50 8 8 ≥3 35 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF50810 50 8 10 ≥3 35 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5092 50 9 2 ≥3 35 8 7 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5094 50 9 4 ≥3 35 8 7 0.035"
Conquest 40 PTA Dilatation Catheters
CQF5098 50 9 8 ≥3 35 8 7 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7542 75 4 2 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7544 75 4 4 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7546 75 4 6 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7548 75 4 8 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF75410 75 4 10 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7552 75 5 2 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7554 75 5 4 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7556 75 5 6 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7558 75 5 8 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF75510 75 5 10 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7562 75 6 2 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7564 75 6 4 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7566 75 6 6 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7568 75 6 8 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF75610 75 6 10 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7572 75 7 2 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7574 75 7 4 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7576 75 7 6 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7578 75 7 8 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF75710 75 7 10 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7582 75 8 2 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7583 75 8 3 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7584 75 8 4 ≥1 40 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7586 75 8 6 ≥3 35 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7588 75 8 8 ≥3 35 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF75810 75 8 10 ≥3 35 8 6 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7592 75 9 2 ≥3 35 8 7 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7594 75 9 4 ≥3 35 8 7 0.035"
Conquest 40 PTA Dilatation Catheters
CQF7598 75 9 8 ≥3 35 8 7 0.035"
Conquest 40 PTA Dilatation Catheters
CQF75102 75 10 2 ≥3 35 8 7 0.035"
Conquest 40 PTA Dilatation Catheters
CQF75104 75 10 4 ≥3 35 8 7 0.035"
Conquest 40 PTA Dilatation Catheters
CQF75108 75 10 8 ≥3 35 8 7 0.035"
Conquest 40 PTA Dilatation Catheters
CQF75122 75 12 2 n/a 30 8 8 0.035"
Conquest 40 PTA Dilatation Catheters
CQF75124 75 12 4 n/a 30 8 8 0.035"
  • Model : CQF5042
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 4
  • Length(cm) : 2
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5044
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 4
  • Length(cm) : 4
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5046
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 4
  • Length(cm) : 6
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5048
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 4
  • Length(cm) : 8
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF50410
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 4
  • Length(cm) : 10
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5052
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 5
  • Length(cm) : 2
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5054
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 5
  • Length(cm) : 4
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5056
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 5
  • Length(cm) : 6
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5058
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 5
  • Length(cm) : 8
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF50510
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 5
  • Length(cm) : 10
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5062
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 6
  • Length(cm) : 2
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5064
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 6
  • Length(cm) : 4
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5066
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 6
  • Length(cm) : 6
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5068
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 6
  • Length(cm) : 8
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF50610
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 6
  • Length(cm) : 10
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5072
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 7
  • Length(cm) : 2
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5074
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 7
  • Length(cm) : 4
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5076
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 7
  • Length(cm) : 6
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5078
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 7
  • Length(cm) : 8
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF50710
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 7
  • Length(cm) : 10
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5082
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 8
  • Length(cm) : 2
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5083
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 8
  • Length(cm) : 3
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5084
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 8
  • Length(cm) : 4
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5086
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 8
  • Length(cm) : 6
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5088
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 8
  • Length(cm) : 8
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF50810
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 8
  • Length(cm) : 10
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF5092
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 9
  • Length(cm) : 2
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 7
  • Guidewire : 0.035"
  • Model : CQF5094
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 9
  • Length(cm) : 4
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 7
  • Guidewire : 0.035"
  • Model : CQF5098
  • Procedure : -
  • Shaft Lengths(cm) : 50
  • Diameter(mm) : 9
  • Length(cm) : 8
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 7
  • Guidewire : 0.035"
  • Model : CQF7542
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 4
  • Length(cm) : 2
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7544
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 4
  • Length(cm) : 4
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7546
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 4
  • Length(cm) : 6
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7548
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 4
  • Length(cm) : 8
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF75410
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 4
  • Length(cm) : 10
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7552
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 5
  • Length(cm) : 2
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7554
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 5
  • Length(cm) : 4
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7556
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 5
  • Length(cm) : 6
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7558
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 5
  • Length(cm) : 8
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF75510
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 5
  • Length(cm) : 10
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7562
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 6
  • Length(cm) : 2
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7564
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 6
  • Length(cm) : 4
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7566
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 6
  • Length(cm) : 6
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7568
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 6
  • Length(cm) : 8
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF75610
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 6
  • Length(cm) : 10
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7572
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 7
  • Length(cm) : 2
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7574
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 7
  • Length(cm) : 4
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7576
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 7
  • Length(cm) : 6
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7578
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 7
  • Length(cm) : 8
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF75710
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 7
  • Length(cm) : 10
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7582
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 8
  • Length(cm) : 2
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7583
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 8
  • Length(cm) : 3
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7584
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 8
  • Length(cm) : 4
  • Syringe Inflation(cc) : ≥1
  • RBP(ATM) : 40
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7586
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 8
  • Length(cm) : 6
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7588
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 8
  • Length(cm) : 8
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF75810
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 8
  • Length(cm) : 10
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 6
  • Guidewire : 0.035"
  • Model : CQF7592
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 9
  • Length(cm) : 2
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 7
  • Guidewire : 0.035"
  • Model : CQF7594
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 9
  • Length(cm) : 4
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 7
  • Guidewire : 0.035"
  • Model : CQF7598
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 9
  • Length(cm) : 8
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 7
  • Guidewire : 0.035"
  • Model : CQF75102
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 10
  • Length(cm) : 2
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 7
  • Guidewire : 0.035"
  • Model : CQF75104
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 10
  • Length(cm) : 4
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 7
  • Guidewire : 0.035"
  • Model : CQF75108
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 10
  • Length(cm) : 8
  • Syringe Inflation(cc) : ≥3
  • RBP(ATM) : 35
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 7
  • Guidewire : 0.035"
  • Model : CQF75122
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 12
  • Length(cm) : 2
  • Syringe Inflation(cc) : n/a
  • RBP(ATM) : 30
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 8
  • Guidewire : 0.035"
  • Model : CQF75124
  • Procedure : -
  • Shaft Lengths(cm) : 75
  • Diameter(mm) : 12
  • Length(cm) : 4
  • Syringe Inflation(cc) : n/a
  • RBP(ATM) : 30
  • Nominal Pressure(atm) : 8
  • Sheath Size (F) : 8
  • Guidewire : 0.035"

Questions & Answers