Manufacturer > TZ Medical Inc. > Devices > Control Mechanical Thrombectomy System

Control Mechanical Thrombectomy System

Device-Type

Closed Fluid Systems

Targated Speciality

Atherectomy

Manufacturer

TZ Medical Inc.


The Control Mechanical Thrombectomy Aspirator combines simplicity with maximum pressure to provide optimal control during thrombectomy procedures. Designed with dual valve technology, vacuum pressure is easily controlled by squeezing and releasing the handle, allowing for continuous force while preventing re-injection of the aspirant. The closed fluid system drains the aspirant directly into the 250 ml collection bag when releasing the handle, providing successful thrombectomy with a fraction of the blood loss compared to pump based systems. Instantly start, stop, increase, decrease, and maintain pulse force with a simple to use system that is easily accessible on the procedure table.

Features and Benefits

  • Instantly start, stop, increase, or decrease force.
  • Complete control of consistent pressure for a fraction of the blood loss.
  • Reset force with each squeeze-release cycle.
  • More vacuum power compared to common pump-based systems.
  • Maintain continuous aspiration force.
  • 250 ml collection bag.
  • Dual valve technology creates a completely closed fluid system.
  • Compatible with all thrombectomy catheters on the market.

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Crossing/Shaft Sheath Size(F) Guidewire Working Length(cm)
Control 11F Mechanical Thrombectomy
ASP-1021 0.050” / 0.137” 11 0.035 90
Control 5F Mechanical Thrombectomy
ASP-1005 0.065” / 0.065” 5 0.035 135
Control 6F Mechanical Thrombectomy
ASP-1009 0.075” / 0.075” 6 0.035 135
Control 7F Mechanical Thrombectomy
ASP-1013 0.050” / 0.090” 7 0.035 90
Control Mechanical Aspirator
ASP-1029 Compatible with any thrombectomy catheter - - -
Control RX Mechanical Thrombectomy
ASP-1001 0.020” / 0.054” 6 0.014 136
  • Model : ASP-1021
  • Procedure : -
  • Crossing/Shaft : 0.050” / 0.137”
  • Sheath Size(F) : 11
  • Guidewire : 0.035
  • Working Length(cm) : 90
  • Model : ASP-1005
  • Procedure : -
  • Crossing/Shaft : 0.065” / 0.065”
  • Sheath Size(F) : 5
  • Guidewire : 0.035
  • Working Length(cm) : 135
  • Model : ASP-1009
  • Procedure : -
  • Crossing/Shaft : 0.075” / 0.075”
  • Sheath Size(F) : 6
  • Guidewire : 0.035
  • Working Length(cm) : 135
  • Model : ASP-1013
  • Procedure : -
  • Crossing/Shaft : 0.050” / 0.090”
  • Sheath Size(F) : 7
  • Guidewire : 0.035
  • Working Length(cm) : 90
  • Model : ASP-1029
  • Procedure : -
  • Crossing/Shaft : Compatible with any thrombectomy catheter
  • Sheath Size(F) : -
  • Guidewire : -
  • Working Length(cm) : -
  • Model : ASP-1001
  • Procedure : -
  • Crossing/Shaft : 0.020” / 0.054”
  • Sheath Size(F) : 6
  • Guidewire : 0.014
  • Working Length(cm) : 136

Questions & Answers