CP Stent (Unmounted)

Device-Type

Balloon-Expandable Covered Stents

Targated Speciality

Cardiovascular

Used in Procedure

Aneurysm Coiling/AVM Treatment


The CP Stent® is a large diameter, balloon expandable stent composed of 0.013” platinum-iridium wire that is arranged in a “zig” pattern. The 8 zig configuration allows expansion from 12mm to 24mm, and the 10 zig configuration allows expansion from 26mm to 30mm.

  • Available bare or covered with an expandable sleeve of ePTFE .
  • 1.6cm–6.0cm stent lengths.


Features and Benefits

Large diameter, balloon expandable stent.

■ Composed of platinum-iridium wire arranged in either an 8 or 10 “zig” pattern.

■ Available bare or covered with an expandable sleeve of ePTFE.

■ 12mm–30mm stent diameters.

■ 1.6cm–6.0cm stent length.

Safety informations

The CP Stent™ and Mounted CP Stent™ are indicated for use in the treatment of native and/or recurrent coarctation of the aorta involving a compliant aortic isthmus or first segment of the descending aorta where there is adequate size and patency of at least one femoral artery and balloon angioplasty is contraindicated or predicted to be ineffective. The Covered CP Stent™ and Covered Mounted CP Stent™ are indicated for use in the treatment of native and/or recurrent coarctation of the aorta involving the aortic isthmus or first segment of the descending aorta where there is adequate size and patency of at least one femoral artery associated with one or more of the following:

• Acute or chronic aortic wall injury.

• Nearly atretic descending aorta of 3 mm or less in diameter.

• A non-compliant stenotic aortic segment found on pre-stent balloon dilation.

• A genetic or congenital syndrome associated with aortic wall weakening or ascending aortic aneurysm.

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
device-thumbnail
Covered CP Stent™
  • Model : CVRDCP8Z16
  • Procedure : -
  • Stent Length (cm) : 1.6
device-thumbnail
Covered CP Stent™
  • Model : CVRDCP8Z22
  • Procedure : -
  • Stent Length (cm) : 2.2
device-thumbnail
Covered CP Stent™
  • Model : CVRDCP8Z28
  • Procedure : -
  • Stent Length (cm) : 2.8
device-thumbnail
Covered CP Stent™
  • Model : CVRDCP8Z34
  • Procedure : -
  • Stent Length (cm) : 3.4
device-thumbnail
Covered CP Stent™
  • Model : CVRDCP8Z39
  • Procedure : -
  • Stent Length (cm) : 3.9
device-thumbnail
Covered CP Stent™
  • Model : CVRDCP8Z45
  • Procedure : -
  • Stent Length (cm) : 4.5
device-thumbnail
CP Stent™
  • Model : CP8Z16
  • Procedure : -
  • Stent Length (cm) : 1.6
device-thumbnail
CP Stent™
  • Model : CP8Z22
  • Procedure : -
  • Stent Length (cm) : 2.2
device-thumbnail
CP Stent™
  • Model : CP8Z28
  • Procedure : -
  • Stent Length (cm) : 2.8
device-thumbnail
CP Stent™
  • Model : CP8Z34
  • Procedure : -
  • Stent Length (cm) : 3.4
device-thumbnail
CP Stent™
  • Model : CP8Z39
  • Procedure : -
  • Stent Length (cm) : 3.9
device-thumbnail
CP Stent™
  • Model : CP8Z45
  • Procedure : -
  • Stent Length (cm) : 4.5