Manufacturer > Cook Medical > Devices > Dawson-Mueller Multipurpose Drainage Catheter

Dawson-Mueller Multipurpose Drainage Catheter

Device-Type

Drainage Catheters

Targated Speciality

Interventional radiology

Manufacturer

Cook Medical


Used for percutaneous drainage in a variety of drainage applications (e.g., nephrostomy, biliary, and abscess), either by direct stick or Seldinger access technique.


Multipurpose Drainage Catheters are constructed from Ultrathane or polyethylene and come in a range of French sizes, lengths and sideport quantities. Locking Loop Catheters are available with one of three types of locking mechanisms:

• Mac-Loe Locking Loop

• Simp-Loc'm Locking Loop

• Cook-Cope Type Loop When ordered with the suffix -HC, the distal part of the catheter, sideports included, has an ACI1 hydrophilic coating. 

Safety informations

INTENDED USE

Multipurpose drainage catheters are intended for percutaneous drainage in a variety of drainage applications (e.g., nephrostomy, biliary and abscess), either by direct stick or Seldinger access technique.


CONTRAINDICATIONS

• Bleeding diathesis and uncontrolled hypertension

• Anticoagulant use 


WARNINGS If a catheter has become malpositioned or if drainage ceases, the catheter should he promptly exchanged or removed. 


PRECAUTIONS

• These products are intended for use by physicians trained and experienced in diagnostic and interventional techniques. Standard techniques for placement of percutaneous drainage catheters should be employed.

• Manipulation of products requires ultrasound, fluoroscopy, or other imaging guidance.

• When inserting a stiffening cannula into a catheter with retention suture, hold suture during cannula insertion to avoid bunching or tangling of suture.

• A TFE-coated wire guide must be used with Ultrathane5 catheters.

• Activate the hydrophilic coating, if present, by wetting the catheter with sterile water or saline. For best results, keep catheter surface wet during placement.

• Catheters should be irrigated on a routine basis to ensure function.

• Patients with indwelling drainage catheters should be evaluated routinely to ensure continuous function of the catheter.

• Traction on the locking suture, if present, should be sufficient to ensure adequate retention of the tip, but should not be overly tight. Verify catheter tip configuration by fluoroscopy.

• It is recommended to use a wire guide when removing a Locking Loop catheter.

• The Peel-Away" Pigtail Straightener, if present, is not to be used as a vascular introducer sheath.

• The potential effects of phthalates on pregnant/nursing women or children have not boon fully characterized and there may be concern for reproductive and developmental effects. 

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
  • Model : G11018
  • Procedure : -
  • Catheter Fr : 5
  • Accepts Wire Guide Diameter inch : .018
  • Catheter Length cm : 25
  • Catheter Sideports : 5
  • Trocar Stylet Needle gage : 23 UTW
  • Model : G51594
  • Procedure : -
  • Catheter Fr : 6.3
  • Accepts Wire Guide Diameter inch : .018
  • Catheter Length cm : 15
  • Catheter Sideports : 5
  • Trocar Stylet Needle gage : 19 UTW
  • Model : G51595
  • Procedure : -
  • Catheter Fr : 6.3
  • Accepts Wire Guide Diameter inch : .035
  • Catheter Length cm : 25
  • Catheter Sideports : 5
  • Trocar Stylet Needle gage : 19 UTW
  • Model : G11020
  • Procedure : -
  • Catheter Fr : 7
  • Accepts Wire Guide Diameter inch : .035
  • Catheter Length cm : 25
  • Catheter Sideports : 5
  • Trocar Stylet Needle gage : 19 UTW
  • Model : G11386
  • Procedure : -
  • Catheter Fr : 8.5
  • Accepts Wire Guide Diameter inch : .038
  • Catheter Length cm : 15
  • Catheter Sideports : 5
  • Trocar Stylet Needle gage : 18
  • Model : G09705
  • Procedure : -
  • Catheter Fr : 8.5
  • Accepts Wire Guide Diameter inch : .038
  • Catheter Length cm : 25
  • Catheter Sideports : 5
  • Trocar Stylet Needle gage : 18
  • Model : G11387
  • Procedure : -
  • Catheter Fr : 10.2
  • Accepts Wire Guide Diameter inch : .038
  • Catheter Length cm : 15
  • Catheter Sideports : 5
  • Trocar Stylet Needle gage : 18
  • Model : G09706
  • Procedure : -
  • Catheter Fr : 10.2
  • Accepts Wire Guide Diameter inch : .038
  • Catheter Length cm : 25
  • Catheter Sideports : 5
  • Trocar Stylet Needle gage : 18
  • Model : G11720
  • Procedure : -
  • Catheter Fr : 12
  • Accepts Wire Guide Diameter inch : .038
  • Catheter Length cm : 15
  • Catheter Sideports : 5
  • Trocar Stylet Needle gage : 18
  • Model : G10435
  • Procedure : -
  • Catheter Fr : 12
  • Accepts Wire Guide Diameter inch : .038
  • Catheter Length cm : 25
  • Catheter Sideports : 5
  • Trocar Stylet Needle gage : 18
  • Model : G10436
  • Procedure : -
  • Catheter Fr : 14
  • Accepts Wire Guide Diameter inch : .038
  • Catheter Length cm : 25
  • Catheter Sideports : 5
  • Trocar Stylet Needle gage : 18

Questions & Answers


Don't see the answer you're looking for ?