Manufacturer > Medtronic > Devices > ECHELON™ 10 Microcatheter

ECHELON™ 10 Microcatheter

Device-Type

Microcatheters

Targated Speciality

Endovascular

Disease Solution

AneurysmTherapy

Manufacturer

Medtronic


The Echelon™ Micro Catheter is an endhole, single-lumen catheter designed to be introduced over a steerable guidewire into the vasculature. The proximal end of the catheter incorporates a standard luer adapter to facilitate the attachment of accessories. The catheter has a semi-rigid proximal shaft which transitions into the flexible distal shaft to facilitate the advancement of the catheter in the anatomy. Dual radiopaque markers at the distal end facilitate fluoroscopic visualization. The outer surface of the catheter is coated to increase lubricity.


Echelon™ microcatheter solutions for aneurysm treatment features a strong nitinol design for confident and stable delivery of coils when minimal paint-brushing effect is desired. 


OVERVIEW


PERFORMANCE AT EVERY TURN. FROM NAVIGATION THROUGH TREATMENT.

Echelon™ microcatheter’s strong nitinol braid technology with progressive picks-per-inch, provides.

  • A balance between pushability and softness via graduated zones and transition points
  • Optimal proximal pushability, stability and support
  • Kink resistance and minimal ovalization to maintain lumen durability for reliable device delivery


SPECIFICATIONS


INDICATIONS

The Echelon™ micro catheter is intended to access peripheral and neuro vasculature for the controlled selective infusion of physician-specified therapeutic agents such as embolization materials and of diagnostic materials such as contrast media.


Features and Benefits

ROBUST DELIVERY, SUSTAINED PUSHABILITY, STABILITY IN TORTUOUSITY 

Echelon™ microcatheter’s strong nitinol braid technology with progressive picks-per-inch, provides.

  • A balance between pushability and softness via graduated zones and transition points.
  • Optimal proximal pushability, stability and support.
  • Kink resistance and minimal ovalisation to maintain lumen durability for reliable device delivery.

CHARACTERISTICS

  • A proximal fluoro-safe marker band
  • Steam-shapeable flexible tip with dual marker bands
  • DMSO Compatible
  • Large 0.017" ID
  • Low profile 0.028" OD


Safety informations

INDICATIONS FOR USE The Echelon™ Micro Catheter is intended to access peripheral and neuro vasculature for the controlled selective infusion of physician-specified therapeutic agents such as embolization materials and of diagnostic materials such as contrast media.


CONTRAINDICATIONS • Not intended for use in the coronary vasculature. • Contraindicated when, in the medical judgment of the physician, such a procedure may compromise the patient’s condition. • Contraindicated for neonatal and pediatric use.


WARNINGS • Infusion pressure with this device should not exceed 600 PSI (4137 kPa). Pressures in excess of 600 PSI (4137 kPa) may result in catheter rupture, which may result in patient injury. • If flow through the micro catheter becomes restricted, do not attempt to clear the device by high pressure infusion. Either remove the micro catheter to determine the cause of the obstruction or replace it with a new micro catheter. Excessive pressure may cause catheter rupture, which may result in patient injury. • Never advance or withdraw an intraluminal device against resistance until the cause of the resistance is determined by fluoroscopy. Excessive force against resistance may result in damage to the device or vessel perforation or other patient injuries. • This device is supplied STERILE for single use only. Do not reprocess or re-sterilize. Reprocessing and re-sterilization increase the risks of patient infection and compromised device performance.


PRECAUTIONS • Ensure embolic material compatibility with catheter prior to use. • Prior to use, carefully examine the micro catheter and packaging to verify that they have not been damaged during shipment. • Prior to use, all accessory devices and agents should be fully prepared according to the manufacturer’s instructions. • Always monitor infusion rates when using the micro catheter. • When injecting contrast for angiography, ensure that the micro catheter is not kinked or occluded. • The micro catheter has a lubricious hydrophilic coating on the outside of the catheter. It must be kept hydrated in order to be lubricious. This can be accomplished by attaching the Y-connector to a continuous saline drip. • When the infusion catheter is in the body, it should be manipulated only under fluoroscopy. Do not attempt to move the micro catheter without observing the resultant tip response. • Because the micro catheter may be easily advanced into narrow, selective vasculature, repeatedly verify (for example by slightly withdrawing the catheter) that the micro catheter has not been advanced so far as to interfere with its removal. 

Potential adverse events

Potential complications include, but are not limited to: • Hematoma at the site of entry • Vessel perforation • Vessel spasm • Hemorrhage • Pain and tenderness • Vascular thrombosis • Thrombolytic episodes • Neurological deficits including stroke and death • Ischemia

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Outer Diameter (F) Inner Diameter (in) Usable Length (in) Max. Guidewire (in) Tip Configuration
Echelon™ 10 Micro Catheter
105-5091-150 2.1>1.7 0.017 150 0.014 Straight
Echelon™ 10 Micro Catheter
145-5091-150 2.1>1.7 0.017 150 0.014 45°
Echelon™ 10 Micro Catheter
190-5091-150 2.1>1.7 0.017 150 0.014 90°
  • Model : 105-5091-150
  • Procedure : -
  • Outer Diameter (F) : 2.1>1.7
  • Inner Diameter (in) : 0.017
  • Usable Length (in) : 150
  • Max. Guidewire (in) : 0.014
  • Tip Configuration : Straight
  • Model : 145-5091-150
  • Procedure : -
  • Outer Diameter (F) : 2.1>1.7
  • Inner Diameter (in) : 0.017
  • Usable Length (in) : 150
  • Max. Guidewire (in) : 0.014
  • Tip Configuration : 45°
  • Model : 190-5091-150
  • Procedure : -
  • Outer Diameter (F) : 2.1>1.7
  • Inner Diameter (in) : 0.017
  • Usable Length (in) : 150
  • Max. Guidewire (in) : 0.014
  • Tip Configuration : 90°

Questions & Answers

Don't see the answer you're looking for ?