Manufacturer > Boston Scientific > Devices > Fathom™ Steerable Guidewires

Fathom™ Steerable Guidewires

Device-Type

Hydrophilic Guidewires

Targated Speciality

Cardiovascular

Manufacturer

Boston Scientific


The Fathom Steerable Guidewires - now with a new angled tip - combine a nitinol hypotube distal segment with advanced microfabrication technology, creating a design that revolutionizes access of the most tortuous vasculature.

Features and Benefits

Taking Fathom to New Lengths

The Fathom Steerable Guidewire combines a nitinol hypotube distal segment with advanced proprietary microfabrication technology, resulting in a Guidewire design that revolutionizes the ability to access the most tortuous vascular beds. Fathom is now available in both 0.016" and 0.014" diameters, in a variety of lengths from 140cm to the new 300cm Fathom-14 Guidewire.

NEW Angled Tip and Radial Lengths

  • Fathom-16 is now available in both 200 and 215cm lengths, specifically designed for radial access procedures
  • Both Fathom-16 and Fathom-14 are now available in a pre-shaped tip designed to help access the most difficult anatomy.

Turn-for-Turn Torque Control

  • Diamond-cut nitinol hypotube is designed to transmit turn-for-turn torque control to enhance responsiveness and maneuverability
  • Lubricious coating on the distal segment and PTFE coating on the stainless steel segment intended to facilitate guidewire placement and catheter tracking

Turn-for-turn torque control with Fathom™ Steerable Guidewire

Enhanced Visualization, Tip Shapeability and Flexibility

  • Platinum-tungsten shapeable distal tip is engineered to achieve accurate placement while maintaining tip shape memory
  • Variable stiffness along the length of the wire balances flexibility without compromising rail support

Fathom™ Steerable Guidewire's Microfabrication Technology

Precise Steerability

Fathom™ Steerable Guidewire precise steerability

Safety informations

FATHOM -14 Steerable Guidewire

INTENDED USE/INDICATIONS FOR USE

The FATHOM -14 Steerable Guidewire is intended for general intravascular use in the peripheral vasculature. It can be used to selectively introduce and position catheters and other interventional devices within the peripheral vasculature. This device should be used only by physicians trained in percutaneous, intravascular techniques and procedures.


CONTRAINDICATIONS

None known.


WARNINGS

The FATHOM Steerable Guidewire is not intended for use in the coronary vasculature or the neuro vasculature.


Fathom-16 Steerable Guidewire

INTENDED USE/INDICATIONS FOR USE

The FATHOM -16 Steerable Guidewire is intended for general intravascular use in the peripheral vasculature. It can be used to selectively introduce and position catheters and other interventional devices within the peripheral vasculature. This device should be used only by physicians trained in percutaneous, intravascular techniques and procedures.


CONTRAINDICATIONS

None known.


WARNINGS

The FATHOM Steerable Guidewire is not intended for use in the coronary vasculature or the neuro vasculature.

Potential adverse events

Complications attributed to endovascular procedures are the following:

  • Vessel trauma
  • Vessel damage
  • Embolism (catheter/device, air bubble, plaque, thrombus, air embolism, thromboembolism)
  • Pseudoaneurysm
  • Seizure/stroke
  • Vessel dissection
  • Hematoma at the puncture site
  • Nerve injury
  • Infection
  • Perforation of the vessel
  • Vessel spasm
  • Hemorrhage
  • Vascular thrombosis
  • Vessel occlusion
  • Death
  • Bleeding
  • Failed treatment
  • Inability to position guidewire
  • Damage to the catheter


Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
  • Model : 50-810
  • Procedure : -
  • Total Length (cm) : 200
  • Nitinol Tip Length (cm) : 35
  • Distal Floppy Tip Length (cm) : 10
  • Proximal/ Distal O.D. (inches) : 0.014
  • Tip Shape : Straight
  • Model : 50-811
  • Procedure : -
  • Total Length (cm) : 200
  • Nitinol Tip Length (cm) : 35
  • Distal Floppy Tip Length (cm) : 10
  • Proximal/ Distal O.D. (inches) : 0.014
  • Tip Shape : Angled
  • Model : 50-814
  • Procedure : -
  • Total Length (cm) : 300
  • Nitinol Tip Length (cm) : 35
  • Distal Floppy Tip Length (cm) : 10
  • Proximal/ Distal O.D. (inches) : 0.014
  • Tip Shape : Straight
  • Model : 50-815
  • Procedure : -
  • Total Length (cm) : 300
  • Nitinol Tip Length (cm) : 35
  • Distal Floppy Tip Length (cm) : 10
  • Proximal/ Distal O.D. (inches) : 0.014
  • Tip Shape : Angled
  • Model : 50-912
  • Procedure : -
  • Total Length (cm) : 180
  • Nitinol Tip Length (cm) : 25
  • Distal Floppy Tip Length (cm) : 10
  • Proximal/ Distal O.D. (inches) : 0.016
  • Tip Shape : Angled
  • Model : 50-920
  • Procedure : -
  • Total Length (cm) : 200
  • Nitinol Tip Length (cm) : 25
  • Distal Floppy Tip Length (cm) : 10
  • Proximal/ Distal O.D. (inches) : 0.016
  • Tip Shape : Straight
  • Model : 50-921
  • Procedure : -
  • Total Length (cm) : 200
  • Nitinol Tip Length (cm) : 25
  • Distal Floppy Tip Length (cm) : 10
  • Proximal/ Distal O.D. (inches) : 0.016
  • Tip Shape : Angled
  • Model : 50-930
  • Procedure : -
  • Total Length (cm) : 215
  • Nitinol Tip Length (cm) : 25
  • Distal Floppy Tip Length (cm) : 10
  • Proximal/ Distal O.D. (inches) : 0.016
  • Tip Shape : Straight
  • Model : 50-931
  • Procedure : -
  • Total Length (cm) : 215
  • Nitinol Tip Length (cm) : 25
  • Distal Floppy Tip Length (cm) : 10
  • Proximal/ Distal O.D. (inches) : 0.016
  • Tip Shape : Angled
  • Model : 50-900
  • Procedure : -
  • Total Length (cm) : 140
  • Nitinol Tip Length (cm) : 25
  • Distal Floppy Tip Length (cm) : 10
  • Proximal/ Distal O.D. (inches) : 0.016
  • Tip Shape : Straight
  • Model : 50-901
  • Procedure : -
  • Total Length (cm) : 140
  • Nitinol Tip Length (cm) : 35
  • Distal Floppy Tip Length (cm) : 20
  • Proximal/ Distal O.D. (inches) : 0.016
  • Tip Shape : Straight
  • Model : 50-910
  • Procedure : -
  • Total Length (cm) : 180
  • Nitinol Tip Length (cm) : 25
  • Distal Floppy Tip Length (cm) : 10
  • Proximal/ Distal O.D. (inches) : 0.016
  • Tip Shape : Straight
  • Model : 50-911
  • Procedure : -
  • Total Length (cm) : 180
  • Nitinol Tip Length (cm) : 35
  • Distal Floppy Tip Length (cm) : 20
  • Proximal/ Distal O.D. (inches) : 0.016
  • Tip Shape : Straight

Questions & Answers

Don't see the answer you're looking for ?