Device-Type

Self-Expanding Stent Grafts

Targated Speciality

Endoscopy

Manufacturer

GORE®

Used in Procedure

Endoscopy


The GORE® VIATORR® TIPS Endoprosthesis is an innovative solution for TIPS in both de novo and revision procedures.


The GORE® VIATORR® TIPS Endoprosthesis is an innovative solution for TIPS in both de novo and revision procedures. The proprietary, reduced permeability ePTFE graft lining minimizes transmural permeation of bile and mucin (which are common causes of patency loss) and minimizes tissue ingrowth into the graft for ease of surgical dissection during liver transplantation. Additionally, it offers improved radial compression strength over the leading, commercially available stents, and ensures secure anchoring with minimal kinking and tissue deformation. The unlined "chain link" segment of the device allows for nutrient portal perfusion.

Features and Benefits

• Lasting Diameter Control

– Control the diameter to reach a targeted portal pressure gradient.

– Size and set the diameter to stay.

• Single Device

– Select from a range of diameters during implantation.

• Performance

– Count on advanced performance that combines a legacy of proven patency with diameter control.

Use Case Examples

INDICATIONS FOR USE IN THE US:

The GORE® VIATORR® TIPS Endoprosthesis is indicated for use in the de novo and revision treatment of portal hypertension and its complications such as variceal bleeding, gastropathy, refractory ascites, and / or hepatic hydrothorax.


INDICATIONS FOR USE UNDER CE MARK:

The GORE® VIATORR® TIPS Endoprosthesis is indicated for use in the treatment of portal hypertension and its complications such as: variceal bleeding refractory to, or intolerant of, conventional therapies, inaccessible varices, gastropathy, refractory ascites, and / or hepatic hydrothorax.

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
  • Model : PT084275
  • Procedure : -
  • Endoprosthesis Diameter (mm) : 8
  • Graft-Lined Length (cm) : 4
  • Unlined Length (cm) : 2
  • Model : PT085275
  • Procedure : -
  • Endoprosthesis Diameter (mm) : 8
  • Graft-Lined Length (cm) : 5
  • Unlined Length (cm) : 2
  • Model : PT086275
  • Procedure : -
  • Endoprosthesis Diameter (mm) : 8
  • Graft-Lined Length (cm) : 6
  • Unlined Length (cm) : 2
  • Model : PT087275
  • Procedure : -
  • Endoprosthesis Diameter (mm) : 8
  • Graft-Lined Length (cm) : 7
  • Unlined Length (cm) : 2
  • Model : PT088275
  • Procedure : -
  • Endoprosthesis Diameter (mm) : 8
  • Graft-Lined Length (cm) : 8
  • Unlined Length (cm) : 2
  • Model : PT104275
  • Procedure : -
  • Endoprosthesis Diameter (mm) : 10
  • Graft-Lined Length (cm) : 4
  • Unlined Length (cm) : 2
  • Model : PT105275
  • Procedure : -
  • Endoprosthesis Diameter (mm) : 10
  • Graft-Lined Length (cm) : 5
  • Unlined Length (cm) : 2
  • Model : PT106275
  • Procedure : -
  • Endoprosthesis Diameter (mm) : 10
  • Graft-Lined Length (cm) : 6
  • Unlined Length (cm) : 2
  • Model : PT107275
  • Procedure : -
  • Endoprosthesis Diameter (mm) : 10
  • Graft-Lined Length (cm) : 7
  • Unlined Length (cm) : 2
  • Model : PT108275
  • Procedure : -
  • Endoprosthesis Diameter (mm) : 10
  • Graft-Lined Length (cm) : 8
  • Unlined Length (cm) : 2