Manufacturer > Teleflex > Devices > GuideLiner® V3 Catheter

GuideLiner® V3 Catheter

Device-Type

Specialty Catheters

Targated Speciality

Endovascular

Manufacturer

Teleflex


Guide extension catheter with half-pipe technology

In 2009, the GuideLiner® Catheter revolutionized the concept of guide extension, creating new possibilities in interventional cardiology. Now in its third generation, the GuideLiner® V3 Catheter continues to build on a history of innovation and performance—one that's been demonstrated with more than half a million catheters in cath labs around the world.

Features and Benefits

Designed to perform

It's not just the proprietary half-pipe technology that sets the GuideLiner® V3 Catheter apart. The coil-reinforced extension is specifically designed to enable dependable deep-seating for the delivery of interventional devices to distal locations.

Half-pipe technology

The half‑pipe channel is designed to minimize device/collar interaction by directing and aligning devices through the collar transition, facilitating smooth device entry and seamless delivery.

Tortuosity tested

From challenging lesions to impossibly acute angles, percutaneous coronary interventions have grown more complex. Since being introduced, GuideLiner® Catheters have been recognized by interventionalists as essential tools for addressing difficult anatomies.

Available in five sizes: 5, 5.5, 6, 7 and 8 Fr.

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Size(F) Required Guide Catheter I.D Push rod O.D Guide Extension I.D. Tip O.D. Rapid Exchange Length(cm) Working Length(cm)
GuideLiner® V3 Catheter
5569 5 5 Fr. I.D. ≥0.056" (1.42 mm) 0.010" (0.25 mm) 0.046" (1.17 mm) 4.0 Fr. (1.35 mm / 0.053") 25 150
GuideLiner® V3 Catheter
5570 5.5 6 Fr. I.D. ≥0.066" (1.68 mm) 0.012" (0.30 mm) 0.051" (1.30 mm) 4.8 Fr. (1.60 mm / 0.063") 25 150
GuideLiner® V3 Catheter
5571 6 6 Fr. I.D. ≥0.070" (1.78 mm) 0.012" (0.30 mm) 0.056" (1.42 mm) 5.1 Fr. (1.70 mm / 0.067") 25 150
GuideLiner® V3 Catheter
5572 7 7 Fr. I.D. ≥0.078" (1.98 mm) 0.012" (0.30 mm) 0.062" (1.57 mm) 5.7 Fr. (1.90 mm / 0.075") 25 150
GuideLiner® V3 Catheter
5573 8 8 Fr. I.D. ≥0.088" (2.24 mm) 0.012" (0.30 mm) 0.071" (1.80 mm) 6.5 Fr. (2.16 mm / 0.085") 25 150
  • Model : 5569
  • Procedure : -
  • Size(F) : 5
  • Required Guide Catheter I.D : 5 Fr. I.D. ≥0.056" (1.42 mm)
  • Push rod O.D : 0.010" (0.25 mm)
  • Guide Extension I.D. : 0.046" (1.17 mm)
  • Tip O.D. : 4.0 Fr. (1.35 mm / 0.053")
  • Rapid Exchange Length(cm) : 25
  • Working Length(cm) : 150
  • Model : 5570
  • Procedure : -
  • Size(F) : 5.5
  • Required Guide Catheter I.D : 6 Fr. I.D. ≥0.066" (1.68 mm)
  • Push rod O.D : 0.012" (0.30 mm)
  • Guide Extension I.D. : 0.051" (1.30 mm)
  • Tip O.D. : 4.8 Fr. (1.60 mm / 0.063")
  • Rapid Exchange Length(cm) : 25
  • Working Length(cm) : 150
  • Model : 5571
  • Procedure : -
  • Size(F) : 6
  • Required Guide Catheter I.D : 6 Fr. I.D. ≥0.070" (1.78 mm)
  • Push rod O.D : 0.012" (0.30 mm)
  • Guide Extension I.D. : 0.056" (1.42 mm)
  • Tip O.D. : 5.1 Fr. (1.70 mm / 0.067")
  • Rapid Exchange Length(cm) : 25
  • Working Length(cm) : 150
  • Model : 5572
  • Procedure : -
  • Size(F) : 7
  • Required Guide Catheter I.D : 7 Fr. I.D. ≥0.078" (1.98 mm)
  • Push rod O.D : 0.012" (0.30 mm)
  • Guide Extension I.D. : 0.062" (1.57 mm)
  • Tip O.D. : 5.7 Fr. (1.90 mm / 0.075")
  • Rapid Exchange Length(cm) : 25
  • Working Length(cm) : 150
  • Model : 5573
  • Procedure : -
  • Size(F) : 8
  • Required Guide Catheter I.D : 8 Fr. I.D. ≥0.088" (2.24 mm)
  • Push rod O.D : 0.012" (0.30 mm)
  • Guide Extension I.D. : 0.071" (1.80 mm)
  • Tip O.D. : 6.5 Fr. (2.16 mm / 0.085")
  • Rapid Exchange Length(cm) : 25
  • Working Length(cm) : 150