Manufacturer > Boston Scientific > Devices > IDC-18 Soft Interlocking Detachable Coil

IDC-18 Soft Interlocking Detachable Coil

Device-Type

Embolization Coil

Manufacturer

Boston Scientific


The IDC-18 Soft Interlocking Detachable Coil is designed to offer precision and control with a soft design for tight packing, nesting, and finishing in coil embolization procedures. Compatible with 0.021" lumen microcatheters, the 0.018" bare microcoil system is beneficial especially in complex and distal peripheral vasculature, and the soft design reduces risk of kickback on the catheter. The interlocking arms allow the coil to be advanced and retracted before final placement, for security in embolization procedures.


Two rigidity levels are available:

  • IDC Regular to complete Interlock packing
  • Designed for smooth and tight packing of the coil in combination with high thrombogenicity and filling capability of Interlock

  • IDC Soft for smooth and elegant finishing
  • Designed for smooth and tight packing during last coil delivery to prevent catheter kickback and last compaction in the target vessel as well as for extra-small vessels.



Each coil is mechanically attached to a coil delivery wire by “interlocking arms”. This simple and elegant design allows the coil to be advanced and retracted before final placement in the vessel, thus aiding in more controlled delivery.”


coil is mechanically attached


Features and Benefits

Simple Detachment via Interlocking Arms - No Handle Required


The interlocking connection is a simple coupling that remains attached while inside the lumen of the catheter. Detachment of the coil requires no additional devices, simply a push outside of the catheter.


IDC-18 Soft Coil


Deploy coil


Detachment Mechanism

Push coil outside of the catheter


Detachment Mechanism

Detachment of coil requires no additional devices


Soft Coil Design

  • Thin wire and soft primary coil wind
  • Designed for smooth, tight nesting of the coil, and reduced risk of catheter kickback, for delicate and accurate finishing during vessel embolization


Precise Placement

  • Interlocking arms offer ability to retract and reposition before detaching, for precise placement


Familiar Technology with Clinical Versatility


  • Same detachment mechanism and microcatheter compatibility as Interlock18, designed to be delivered through a 0.021 in inner lumen microcatheter [0.53 mm] such as the Direxion small-lumen microcatheter
  • Range of sizes (from extra small 2mm x 2cm to long) to facilitate use in extra small peripheral vessels, delicate finishing needs, and for tight packing in large aneurysms


Safety informations

INTENDED USE/INDICATIONS FOR USE

The Interlock IDC Occlusion System is a modified interlocking detachable coil. The Interlock IDC Occlusion Systems are indicated for obstructing or reducing blood flow in the peripheral vasculature during embolization procedures. These devices are not intended for neurovascular use.

CONTRAINDICATIONS

None known.

PRECAUTIONS

Do not attempt to use the Interlock - 35 Fibered IDC Occlusion System with a soft-walled delivery catheter.

Do not advance the Interlock IDC Occlusion System if it becomes lodged within the catheter. Determine the cause of the resistance and replace the catheter and coil if necessary.

Potential adverse events

The complications that may result from a peripheral embolization procedure include, but are not limited to:

  • Complications related to catheterization (e.g., hematoma at the site of entry, clot formation at the tip of the catheter and subsequent dislodgement, nerve and vessel dissection or perforation, etc.)
  • Pain
  • Hemorrhage
  • Infection necessitating medical intervention
  • Foreign body reactions necessitating medical intervention
  • Emboli
  • Ischemia
  • Vasospasm
  • Tissue necrosis
  • Undesirable clot formation of the vasculature
  • Recanalization
  • Death
  • Temporary neurological deficit


Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
  • Model : M0033612020
  • Procedure : -
  • Diameter (mm) : 2
  • length (mm) : 20
  • Shape : 2D
  • Model : M0013612040
  • Procedure : -
  • Diameter (mm) : 2
  • length (mm) : 40
  • Shape : 2D
  • Model : M0013613060
  • Procedure : -
  • Diameter (mm) : 3
  • length (mm) : 60
  • Shape : 2D
  • Model : M0013613100
  • Procedure : -
  • Diameter (mm) : 3
  • length (mm) : 100
  • Shape : 2D
  • Model : M0013614040
  • Procedure : -
  • Diameter (mm) : 4
  • length (mm) : 40
  • Shape : 2D
  • Model : M0013614080
  • Procedure : -
  • Diameter (mm) : 4
  • length (mm) : 80
  • Shape : 2D
  • Model : M0013614120
  • Procedure : -
  • Diameter (mm) : 4
  • length (mm) : 120
  • Shape : 2D
  • Model : M0013615080
  • Procedure : -
  • Diameter (mm) : 5
  • length (mm) : 80
  • Shape : 2D
  • Model : M0013615120
  • Procedure : -
  • Diameter (mm) : 5
  • length (mm) : 120
  • Shape : 2D

Questions & Answers