Manufacturer > Boston Scientific > Devices > LeVeen™ & LeVeen SuperSlim™ Needle Electrodes

LeVeen™ & LeVeen SuperSlim™ Needle Electrodes

Device-Type

Ablation System

Targated Speciality

Radiofrequency

Manufacturer

Boston Scientific


Designed for Use with RF 3000™ Radiofrequency Generator

Innovative Electrode Design

• 5cm array is designed to create larger thermal lesions and reduce the need for overlapping ablations

• Expanded portfolio of array diameters – from 2cm to 5cm – enhances ability to treat lesions of variable dimensions

• Sharp, polished array tips facilitate tissue penetration

• Umbrella-shaped array design promotes stable, accurate deployment

• Consistent tine spacing is designed to help create a complete, predictable, spherical thermal lesion

• Continuous impedance feedback facilitates accurate assessment of complete thermal lesion formation

Cannula Design

• LeVeen SuperSlim Electrode cannula design options provide an excellent choice for patients who are at risk of bleeding

• Short, lightweight LeVeen SuperSlim Electrode handle facilitates gantry clearance during CT-monitored ablations

• 1cm shaft markers and echogenic tip help to guide insertion

• Choice of lengths facilitates lesion access

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
  • Model : M001262160
  • Procedure : -
  • Array Diameter (cm) : 5
  • Cannula Length (cm) : 15
  • Model : M001262170
  • Procedure : -
  • Array Diameter (cm) : 5
  • Cannula Length (cm) : 25
  • Model : M001262130
  • Procedure : -
  • Array Diameter (cm) : 4
  • Cannula Length (cm) : 15
  • Model : M001262310
  • Procedure : -
  • Array Diameter (cm) : 4
  • Cannula Length (cm) : 25
  • Model : M001262020
  • Procedure : -
  • Array Diameter (cm) : 3.5
  • Cannula Length (cm) : 12
  • Model : M001262030
  • Procedure : -
  • Array Diameter (cm) : 3.5
  • Cannula Length (cm) : 15
  • Model : M001262150
  • Procedure : -
  • Array Diameter (cm) : 3.5
  • Cannula Length (cm) : 25
  • Model : M001262040
  • Procedure : -
  • Array Diameter (cm) : 3
  • Cannula Length (cm) : 12
  • Model : M001262050
  • Procedure : -
  • Array Diameter (cm) : 3
  • Cannula Length (cm) : 15
  • Model : M001262290
  • Procedure : -
  • Array Diameter (cm) : 3
  • Cannula Length (cm) : 25
  • Model : M001262280
  • Procedure : -
  • Array Diameter (cm) : 3
  • Cannula Length (cm) : 15
  • Model : M001262270
  • Procedure : -
  • Array Diameter (cm) : 2
  • Cannula Length (cm) : 25
  • Model : M001262260
  • Procedure : -
  • Array Diameter (cm) : 2
  • Cannula Length (cm) : 15

Questions & Answers