Manufacturer > Medtronic > Devices > NAVIEN™ Intracranial Support Catheter

NAVIEN™ Intracranial Support Catheter

Device-Type

Guiding Catheters

Manufacturer

Medtronic


The Navien™ A+ Intracranial Support Catheter is a single lumen, flexible, variable stiffness composite catheter. The catheter shaft has a hydrophilic coating to reduce friction during use. The Navien A+ Intracranial Support Catheter shaft is visible under fluoroscopy. The Navien A+ Intracranial Support Catheter dimensions are included on the individual device label. The Navien A+ Intracranial Support Catheter inner lumen can accommodate guide wires up to 0.038 inches in diameter to aid in placement of the catheter system. The proximal end of the Navien A+ Intracranial Support Catheter has a luer fitting to allow attachment of accessories and infusion of liquids through the system. The Navien A+ Intracranial Support Catheter is offered in various sizes to accommodate physician preferences and anatomical variations. The catheter is provided sterile, nonpyrogenic, and is intended for single use only.


NAVIEN™ INTRACRANIAL SUPPORT CATHETER DEVICE DETAILS

Navien catheter with features called out 1-5. Read description of these features directly below this image.

  1. Flat Wire Nitinol Coil - Enables maintenance of lumen inner diameter 
  2. Polyester Jacket - Provides proximal stability and distal flexibility
  3. Polymer Adhesive - Binding agent for layers 
  4. Platinum Coil Marker - provides radiopacity of tip 
  5. PTFE Liner - Smooth delivery of microcatheters and interventional devices 





Features and Benefits

The Navien™ intracranial support catheter has a nitinol coil and proprietary polymers to deliver thin wall construction1 that provides a large ID among 5/6 Fr catheters2 while delivering improved trackability1,2 and resistance to ovalization.3,4

  • Liquid embolic system
  • Flow diversion device and coiling
  • Contrast run
  • Balloon-assisted coiling
  • Removal/aspiration of fresh, soft emboli and thrombi
  • Stent-assisted coiling



CLINICAL ADVANTAGES


The large inner diameter (5F: 0.058” - 6F: 0.072”) is providing more clinical treatment options:

  • Higher flow rate enables better contrast injections and visualization
  • Higher aspiration rates*
  • Capture of larger pieces of clot
  • More flexibility, allowing the use of different device combinations
  • With its specific braiding, the Navien™ is a durable guide catheter with low ovalization rates
  • Large inner diameter among 5/6 Fr catheters
  • Device Flexibility
  • Increased Contrast Flow
  • Low Trackability Force
  • Low Ovalization Rate


CHARACTERISTICS

  • Provides the micro catheter with a distal base of support
  • Micro catheter stability
  • Infusion of contrast in large volume 



Safety informations

INDICATIONS FOR USE

The Navien Intracranial Support Catheter is indicated for the introduction of interventional devices into the peripheral and neuro vasculature.

CAUTION

  • Federal (USA) law restricts this device to sale, distribution, and use by or on the order of a physician.
  • This device should be used only by physicians with a thorough understanding of angiography and percutaneous interventional procedures.

PRECAUTIONS

  • Store in a cool, dry, dark place.
  • Do not use kinked or damaged devices.
  • Do not use open or damaged packages.
  • Use prior to the “Use By” date.
  • Exposure to temperatures above 54°C (130°F) may damage device and accessories. Do not autoclave.
  • Use the Navien Intracranial Support Catheter in conjunction with fluoroscopic visualization.
  • Inspect the catheter system before use to verify that its size and condition are suitable for the specific procedure.
  • Do not advance or withdraw Navien Intracranial Support Catheter against resistance without careful assessment of the cause using fluoroscopy. If the cause cannot be determined, withdraw the device. Moving or torquing the device against resistance may result in damage to the vessel or device.
  • Maintain a constant infusion of appropriate flush solution.
  • If flow through the catheter becomes restricted, do not attempt to clear the lumen by infusion. Remove and replace the device.
  • Extreme care must be taken to avoid damage to the vasculature through which the catheter passes. The catheter may occlude smaller vessels. Care must be taken to avoid complete blood flow blockage.
  • Torquing the catheter may cause damage which could result in kinking and possible separation along the catheter shaft. Should the system become severely kinked, withdraw the entire system (Navien Intracranial Support Catheter, guide wire and catheter sheath introducer).

CONTRAINDICATIONS

There are no known contraindications.

COMPATIBILITY

Refer to product label for device dimensions. Refer to labelling provided with other medical technologies to determine compatibility.


WARNINGS

  • The Navien Intracranial Support Catheter should only be used by physicians who have received appropriate training in interventional techniques. 
  • Do not reuse. The device is intended for single use only. Discard the catheter after one procedure. Structural integrity and/or function may be impaired through reuse or cleaning. Catheters are extremely difficult to clean after exposure to biological materials and may cause adverse patient reactions if reused.


Potential adverse events

Potential complications include, but are not limited to, the following:

  • acute occlusion
  • air embolism
  • death
  • distal embolization
  • emboli
  • false aneurysm formation
  • hematoma or hemorrhage at puncture site 
  • infection
  • intracranial haemorrhage
  • ischemia
  • neurological deficit
  • including stroke
  • vessel spasm, thrombosis, dissection or perforation


Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Size OD ID Length Distal Flexible Length Tip Shape
NAVIEN™ Intracranial Support Catheter
RFX058-105-08 5F 5 F / .070" max .058" 105 cm 8 cm Straight
NAVIEN™ Intracranial Support Catheter
RFX058-115-08 5F 5 F / .070" max .058" 115 cm 8 cm Straight
NAVIEN™ Intracranial Support Catheter
RFX058-125-08 5F 5 F / .070" max .058" 125 cm 8 cm Straight
NAVIEN™ Intracranial Support Catheter
RFX058-130-08 5F 5 F / .070" max .058" 150 cm 8 cm Straight
NAVIEN™ Intracranial Support Catheter
RFX072-95-08 6F 6 F / .084" max .072" 95 cm 8 cm Straight
NAVIEN™ Intracranial Support Catheter
RFX072-95-08MP 6F 6 F / .084" max .072" 95 cm 8 cm Multi-Purpose 25°
NAVIEN™ Intracranial Support Catheter
RFX072-105-08 6F 6 F / .084" max .072" 105 cm 8 cm Straight
NAVIEN™ Intracranial Support Catheter
RFX072-105-08MP 6F 6 F / .084" max .072" 105 cm 8 cm Multi-Purpose 25°
NAVIEN™ Intracranial Support Catheter
RFX072-115-08 6F 6 F / .084" max .072" 115 cm 8 cm Straight
NAVIEN™ Intracranial Support Catheter
RFX072-115-08MP 6F 6 F / .084" max .072" 115 cm 8 cm Multi-Purpose 25°
NAVIEN™ Intracranial Support Catheter
RFX072-125-08 6F 6 F / .084" max .072" 125 cm 8 cm Straight
NAVIEN™ Intracranial Support Catheter
RFX072-125-08MP 6F 6 F / .084" max .072" 125 cm 8 cm Multi-Purpose 25°
NAVIEN™ Intracranial Support Catheter
RFX072-130-08 6F 6 F / .084" max .072" 130 cm 8 cm Straight
NAVIEN™ Intracranial Support Catheter
RFX072-130-08MP 6F 6 F / .084" max .072" 130 cm 8 cm Multi-Purpose 25°
  • Model : RFX058-105-08
  • Procedure : -
  • Size : 5F
  • OD : 5 F / .070" max
  • ID : .058"
  • Length : 105 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Straight
  • Model : RFX058-115-08
  • Procedure : -
  • Size : 5F
  • OD : 5 F / .070" max
  • ID : .058"
  • Length : 115 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Straight
  • Model : RFX058-125-08
  • Procedure : -
  • Size : 5F
  • OD : 5 F / .070" max
  • ID : .058"
  • Length : 125 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Straight
  • Model : RFX058-130-08
  • Procedure : -
  • Size : 5F
  • OD : 5 F / .070" max
  • ID : .058"
  • Length : 150 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Straight
  • Model : RFX072-95-08
  • Procedure : -
  • Size : 6F
  • OD : 6 F / .084" max
  • ID : .072"
  • Length : 95 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Straight
  • Model : RFX072-95-08MP
  • Procedure : -
  • Size : 6F
  • OD : 6 F / .084" max
  • ID : .072"
  • Length : 95 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Multi-Purpose 25°
  • Model : RFX072-105-08
  • Procedure : -
  • Size : 6F
  • OD : 6 F / .084" max
  • ID : .072"
  • Length : 105 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Straight
  • Model : RFX072-105-08MP
  • Procedure : -
  • Size : 6F
  • OD : 6 F / .084" max
  • ID : .072"
  • Length : 105 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Multi-Purpose 25°
  • Model : RFX072-115-08
  • Procedure : -
  • Size : 6F
  • OD : 6 F / .084" max
  • ID : .072"
  • Length : 115 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Straight
  • Model : RFX072-115-08MP
  • Procedure : -
  • Size : 6F
  • OD : 6 F / .084" max
  • ID : .072"
  • Length : 115 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Multi-Purpose 25°
  • Model : RFX072-125-08
  • Procedure : -
  • Size : 6F
  • OD : 6 F / .084" max
  • ID : .072"
  • Length : 125 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Straight
  • Model : RFX072-125-08MP
  • Procedure : -
  • Size : 6F
  • OD : 6 F / .084" max
  • ID : .072"
  • Length : 125 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Multi-Purpose 25°
  • Model : RFX072-130-08
  • Procedure : -
  • Size : 6F
  • OD : 6 F / .084" max
  • ID : .072"
  • Length : 130 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Straight
  • Model : RFX072-130-08MP
  • Procedure : -
  • Size : 6F
  • OD : 6 F / .084" max
  • ID : .072"
  • Length : 130 cm
  • Distal Flexible Length : 8 cm
  • Tip Shape : Multi-Purpose 25°

Questions & Answers