See your way to accurate stent deployment when you choose the ParaMount™ Mini GPS™ balloon-expandable biliary stent system with its radiopaque markers that enhance visibility before, during and after stent placement. The system's low profile is designed for flexibility and easy navigation during palliative treatment of a malignant neoplasm in the biliary tree.

Features and Benefits

HIGH VISIBILITY

  • GPS radiopaque tantalum markers are built into each end of the stent for enhanced procedural accuracy and visibility.
  • GPS markers identify proximal and distal edges as the stent is expanded.
  • GPS technology allows stent to remain visible under fluoroscopy to verify stent placement.

Location of GPS radiopaque markers on the end of a Paramount Mini GPS stent.



GPS Markers

Location of GPS radiopaque markers on the end of a ParaMount Mini GPS stent.

LOW PROFILE SYSTEM

  • Available on either an 0.014" and 0.018" guidewire compatible balloon catheter.
  • Compatible with a 6 F or 7 F guide catheter.
  • Designed for flexibility when navigating to a target lesion.

STRENGTH AND FLEXIBILITY

  • Unique cell geometry provides greater radial strength and support.

PRECISION

  • Medtronic's exclusive Micro-Grip™ technology keeps the stent properly centered prior to expansion.
  • Stent exhibits minimal shortening at recommended expansion diameters

Safety informations

This therapy is not for everyone. Please consult your physician. A prescription is required. For more information, please call Medtronic. Prior to use, refer to the Instructions for Use supplied with these devices for indications, contraindications, side effects, suggested procedure, warnings and precautions. 

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Expanded Stent Diameter (mm) Expanded Stent Length (mm) Balloon Length (mm) Recommended Guide Catheter/ Sheath Size Guidewire Acceptance (in)
ParaMount Mini GPS Stent
PMB4-5-14-80 5 14 17 6/5 0.014
ParaMount Mini GPS Stent
PMB4-5-18-80 5 18 20 6/5 0.014
ParaMount Mini GPS Stent
PMB4-5-21-80 5 21 24 6/5 0.014
ParaMount Mini GPS Stent
PMB4-6-14-80 6 14 17 6*/5 0.014
ParaMount Mini GPS Stent
PMB4-6-18-80 6 18 20 6*/5 0.014
ParaMount Mini GPS Stent
PMB4-6-21-80 6 21 24 6*/5 0.014
ParaMount Mini GPS Stent
PMB4-7-14-80 7 14 17 7/5 0.014
ParaMount Mini GPS Stent
PMB4-7-18-80 7 18 20 7/5 0.014
ParaMount Mini GPS Stent
PMB4-7-21-80 7 21 24 7/5 0.014
ParaMount Mini GPS Stent
PMB8-5-14-80 5 14 17 6/5 0.018
ParaMount Mini GPS Stent
PMB8-5-18-80 5 18 20 6/5 0.018
ParaMount Mini GPS Stent
PMB8-5-21-80 5 21 24 6/5 0.018
ParaMount Mini GPS Stent
PMB8-6-14-80 6 14 17 6*/5 0.018
ParaMount Mini GPS Stent
PMB8-6-18-80 6 18 20 6*/5 0.018
ParaMount Mini GPS Stent
PMB8-6-21-80 6 21 24 6*/5 0.018
ParaMount Mini GPS Stent
PMB8-7-14-80 7 14 17 7/5 0.018
ParaMount Mini GPS Stent
PMB8-7-18-80 7 18 20 7/5 0.018
ParaMount Mini GPS Stent
PMB8-7-21-80 7 21 24 7/5 0.018
  • Model : PMB4-5-14-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 5
  • Expanded Stent Length (mm) : 14
  • Balloon Length (mm) : 17
  • Recommended Guide Catheter/ Sheath Size : 6/5
  • Guidewire Acceptance (in) : 0.014
  • Model : PMB4-5-18-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 5
  • Expanded Stent Length (mm) : 18
  • Balloon Length (mm) : 20
  • Recommended Guide Catheter/ Sheath Size : 6/5
  • Guidewire Acceptance (in) : 0.014
  • Model : PMB4-5-21-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 5
  • Expanded Stent Length (mm) : 21
  • Balloon Length (mm) : 24
  • Recommended Guide Catheter/ Sheath Size : 6/5
  • Guidewire Acceptance (in) : 0.014
  • Model : PMB4-6-14-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 6
  • Expanded Stent Length (mm) : 14
  • Balloon Length (mm) : 17
  • Recommended Guide Catheter/ Sheath Size : 6*/5
  • Guidewire Acceptance (in) : 0.014
  • Model : PMB4-6-18-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 6
  • Expanded Stent Length (mm) : 18
  • Balloon Length (mm) : 20
  • Recommended Guide Catheter/ Sheath Size : 6*/5
  • Guidewire Acceptance (in) : 0.014
  • Model : PMB4-6-21-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 6
  • Expanded Stent Length (mm) : 21
  • Balloon Length (mm) : 24
  • Recommended Guide Catheter/ Sheath Size : 6*/5
  • Guidewire Acceptance (in) : 0.014
  • Model : PMB4-7-14-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 7
  • Expanded Stent Length (mm) : 14
  • Balloon Length (mm) : 17
  • Recommended Guide Catheter/ Sheath Size : 7/5
  • Guidewire Acceptance (in) : 0.014
  • Model : PMB4-7-18-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 7
  • Expanded Stent Length (mm) : 18
  • Balloon Length (mm) : 20
  • Recommended Guide Catheter/ Sheath Size : 7/5
  • Guidewire Acceptance (in) : 0.014
  • Model : PMB4-7-21-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 7
  • Expanded Stent Length (mm) : 21
  • Balloon Length (mm) : 24
  • Recommended Guide Catheter/ Sheath Size : 7/5
  • Guidewire Acceptance (in) : 0.014
  • Model : PMB8-5-14-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 5
  • Expanded Stent Length (mm) : 14
  • Balloon Length (mm) : 17
  • Recommended Guide Catheter/ Sheath Size : 6/5
  • Guidewire Acceptance (in) : 0.018
  • Model : PMB8-5-18-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 5
  • Expanded Stent Length (mm) : 18
  • Balloon Length (mm) : 20
  • Recommended Guide Catheter/ Sheath Size : 6/5
  • Guidewire Acceptance (in) : 0.018
  • Model : PMB8-5-21-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 5
  • Expanded Stent Length (mm) : 21
  • Balloon Length (mm) : 24
  • Recommended Guide Catheter/ Sheath Size : 6/5
  • Guidewire Acceptance (in) : 0.018
  • Model : PMB8-6-14-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 6
  • Expanded Stent Length (mm) : 14
  • Balloon Length (mm) : 17
  • Recommended Guide Catheter/ Sheath Size : 6*/5
  • Guidewire Acceptance (in) : 0.018
  • Model : PMB8-6-18-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 6
  • Expanded Stent Length (mm) : 18
  • Balloon Length (mm) : 20
  • Recommended Guide Catheter/ Sheath Size : 6*/5
  • Guidewire Acceptance (in) : 0.018
  • Model : PMB8-6-21-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 6
  • Expanded Stent Length (mm) : 21
  • Balloon Length (mm) : 24
  • Recommended Guide Catheter/ Sheath Size : 6*/5
  • Guidewire Acceptance (in) : 0.018
  • Model : PMB8-7-14-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 7
  • Expanded Stent Length (mm) : 14
  • Balloon Length (mm) : 17
  • Recommended Guide Catheter/ Sheath Size : 7/5
  • Guidewire Acceptance (in) : 0.018
  • Model : PMB8-7-18-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 7
  • Expanded Stent Length (mm) : 18
  • Balloon Length (mm) : 20
  • Recommended Guide Catheter/ Sheath Size : 7/5
  • Guidewire Acceptance (in) : 0.018
  • Model : PMB8-7-21-80
  • Procedure : -
  • Expanded Stent Diameter (mm) : 7
  • Expanded Stent Length (mm) : 21
  • Balloon Length (mm) : 24
  • Recommended Guide Catheter/ Sheath Size : 7/5
  • Guidewire Acceptance (in) : 0.018