Successful peripheral embolization requires a systematic approach including guidewires, catheters, coils, and/or embolic materials. VortX 18 and 35 Vascular Occlusion Coils are designed with a proprietary conical shape and an apex-first deployment. VortX Coils are pushable coils designed to provide compact, complete vascular occlusion and efficient embolization.

Features and Benefits

Product Details

  • The conical shape and dense polyester fiber placement of the VortX Vascular Occlusion Coils are designed to promote complete vascular occlusion and thrombosis.
  • The placement of dense polyester fibers promotes thrombosis.
  • A platinum construction enhances visualization under fluoroscopy.
  • Round coil ends are designed to ease advancement through microcatheters and reduce potential for vessel wall trauma.
  • A long overall coil length provides increased mass per coil compared to shorter coils used for occlusion.

Safety informations

VortX-18 Fibered Platinum Coil


INTENDED USE/INDICATIONS FOR USE

Boston Scientific’s 0.018 Fibered Platinum Coils are intended for arterial and venous embolizations in the peripheral vasculature.

The Coil Pusher-16 is intended to be used in conjunction with a microcatheter to deliver and deploy 0.018 pushable occlusion coils.

CONTRAINDICATIONS

None known.

PRECAUTIONS

  • The long-term effect of this product on extravascular tissues has not been established, so care should be taken to retain this device in the intravascular space.
  • Do not advance the coil with force if the coil becomes lodged within the microcatheter. Determine the cause of resistance and replace the microcatheter and the coil when necessary.
  • Replace the microcatheter if increased resistance is noted during coil delivery.


VortX-35 Fibered Platinum Coil


INTENDED USE/INDICATIONS FOR USE

VortX - 35 and 2D Helical - 35 Fibered Platinum Coils are intended for arterial and venous embolizations in the peripheral vasculature.

CONTRAINDICATIONS

None known.

WARNINGS

Never advance the guidewire after coil has been deposited. Advancing the guidewire after the coil has been deposited risks damaging the vessel.

PRECAUTIONS

In preclinical studies, the use of this device has been associated with a minor chronic inflammation of a giant cell foreign body reaction. Although inflammation of this type has not been observed in humans, the long term clinical significance of this type of inflammatory response, if any, is unknown. The long term effect of this product on extravascular tissues has not been established, so care should be taken to retain this device in the intravascular space. Do not advance the coil with force if the coil becomes lodged within the catheter. Determine the cause of resistance and replace the catheter and the coil when necessary. Replace catheter frequently if increased resistance is noted during coil delivery.

Potential adverse events

VortX-18 Fibered Platinum Coil


The complications that may result from a peripheral embolization procedure include, but are not limited to:

  • Complications related to catheterization (e.g., hematoma at the site of entry, vessel injury, etc.)
  • Death
  • Emboli
  • Foreign body reactions necessitating medical intervention
  • Hemorrhage
  • Infection necessitating medical intervention
  • Ischemia
  • Pain
  • Recanalization
  • Temporary neurological deficit
  • Tissue necrosis
  • Undesirable clot formation of the vasculature
  • Vasospasm


VortX-35 Fibered Platinum Coil


The complications that may result from a peripheral embolization procedure include, but are not limited to:

  • Complications related to catheterization (e.g., hematoma at the site of entry, vessel injury, etc.)
  • Death
  • Emboli
  • Foreign body reactions necessitating medical intervention
  • Hemorrhage
  • Infection necessitating medical intervention
  • Ischemia
  • Pain
  • Recanalization
  • Temporary neurological deficit
  • Tissue necrosis
  • Undesirable clot formation of the vasculature
  • Vasospasm


Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Maximum Diameter (mm) Unrestrained Coil Length (mm) Length in Introducer (mm)
2D Helical 35
M0013723021 3 2.6 20
2D Helical 35
M0013723041 3 5.2 40
2D Helical 35
M0013724031 4 2.9 30
2D Helical 35
M0013725031 5 2.4 30
2D Helical 35
M0013725051 5 4 50
2D Helical 35
M0013726041 6 2.6 40
2D Helical 35
M0013727041 7 2.3 40
2D Helical 35
M0013729061 9 2.7 60
Complex Helical 18
M0013120221 4 4 20
Complex Helical 18
M0013120331 6 6 30
Complex Helical 18
M0013120441 7 10 40
Complex Helical 18
M0013120551 8 12 50
Complex Helical 18
M0013120661 10 14 60
Complex Helical 18
M0013120771 11 17 70
Multi-Loop 18
M0013120431 4 7 30
Straight 18
M0013120021 Straight 2 2
Straight 18
M0013120051 Straight 5 5
VortX 18
M0013812031 3 2.5 22
VortX 18
M0013812041 4 4 42
VortX 18
M0013812051 5 5.5 60
VortX 18
M0013812061 6 6.5 85
VortX 35
M0013732041 4 4 30
VortX 35
M0013733051 5 4.5 35
VortX 35
M0013733061 6 5 53
VortX 35
M0013733071 7 5.5 67
VortX Diamond 18
M0013822031 3 3.3 23
VortX Diamond 18
M0013822041 4 3.7 41
VortX Diamond 18
M0013822051 5 5.5 58
VortX Diamond 18
M0013822061 6 6.7 80
device-thumbnail
2D Helical 35
  • Model : M0013723021
  • Procedure : -
  • Maximum Diameter (mm) : 3
  • Unrestrained Coil Length (mm) : 2.6
  • Length in Introducer (mm) : 20
device-thumbnail
2D Helical 35
  • Model : M0013723041
  • Procedure : -
  • Maximum Diameter (mm) : 3
  • Unrestrained Coil Length (mm) : 5.2
  • Length in Introducer (mm) : 40
device-thumbnail
2D Helical 35
  • Model : M0013724031
  • Procedure : -
  • Maximum Diameter (mm) : 4
  • Unrestrained Coil Length (mm) : 2.9
  • Length in Introducer (mm) : 30
device-thumbnail
2D Helical 35
  • Model : M0013725031
  • Procedure : -
  • Maximum Diameter (mm) : 5
  • Unrestrained Coil Length (mm) : 2.4
  • Length in Introducer (mm) : 30
device-thumbnail
2D Helical 35
  • Model : M0013725051
  • Procedure : -
  • Maximum Diameter (mm) : 5
  • Unrestrained Coil Length (mm) : 4
  • Length in Introducer (mm) : 50
device-thumbnail
2D Helical 35
  • Model : M0013726041
  • Procedure : -
  • Maximum Diameter (mm) : 6
  • Unrestrained Coil Length (mm) : 2.6
  • Length in Introducer (mm) : 40
device-thumbnail
2D Helical 35
  • Model : M0013727041
  • Procedure : -
  • Maximum Diameter (mm) : 7
  • Unrestrained Coil Length (mm) : 2.3
  • Length in Introducer (mm) : 40
device-thumbnail
2D Helical 35
  • Model : M0013729061
  • Procedure : -
  • Maximum Diameter (mm) : 9
  • Unrestrained Coil Length (mm) : 2.7
  • Length in Introducer (mm) : 60
device-thumbnail
Complex Helical 18
  • Model : M0013120221
  • Procedure : -
  • Maximum Diameter (mm) : 4
  • Unrestrained Coil Length (mm) : 4
  • Length in Introducer (mm) : 20
device-thumbnail
Complex Helical 18
  • Model : M0013120331
  • Procedure : -
  • Maximum Diameter (mm) : 6
  • Unrestrained Coil Length (mm) : 6
  • Length in Introducer (mm) : 30
device-thumbnail
Complex Helical 18
  • Model : M0013120441
  • Procedure : -
  • Maximum Diameter (mm) : 7
  • Unrestrained Coil Length (mm) : 10
  • Length in Introducer (mm) : 40
device-thumbnail
Complex Helical 18
  • Model : M0013120551
  • Procedure : -
  • Maximum Diameter (mm) : 8
  • Unrestrained Coil Length (mm) : 12
  • Length in Introducer (mm) : 50
device-thumbnail
Complex Helical 18
  • Model : M0013120661
  • Procedure : -
  • Maximum Diameter (mm) : 10
  • Unrestrained Coil Length (mm) : 14
  • Length in Introducer (mm) : 60
device-thumbnail
Complex Helical 18
  • Model : M0013120771
  • Procedure : -
  • Maximum Diameter (mm) : 11
  • Unrestrained Coil Length (mm) : 17
  • Length in Introducer (mm) : 70
device-thumbnail
Multi-Loop 18
  • Model : M0013120431
  • Procedure : -
  • Maximum Diameter (mm) : 4
  • Unrestrained Coil Length (mm) : 7
  • Length in Introducer (mm) : 30
device-thumbnail
Straight 18
  • Model : M0013120021
  • Procedure : -
  • Maximum Diameter (mm) : Straight
  • Unrestrained Coil Length (mm) : 2
  • Length in Introducer (mm) : 2
device-thumbnail
Straight 18
  • Model : M0013120051
  • Procedure : -
  • Maximum Diameter (mm) : Straight
  • Unrestrained Coil Length (mm) : 5
  • Length in Introducer (mm) : 5
device-thumbnail
VortX 18
  • Model : M0013812031
  • Procedure : -
  • Maximum Diameter (mm) : 3
  • Unrestrained Coil Length (mm) : 2.5
  • Length in Introducer (mm) : 22
device-thumbnail
VortX 18
  • Model : M0013812041
  • Procedure : -
  • Maximum Diameter (mm) : 4
  • Unrestrained Coil Length (mm) : 4
  • Length in Introducer (mm) : 42
device-thumbnail
VortX 18
  • Model : M0013812051
  • Procedure : -
  • Maximum Diameter (mm) : 5
  • Unrestrained Coil Length (mm) : 5.5
  • Length in Introducer (mm) : 60
device-thumbnail
VortX 18
  • Model : M0013812061
  • Procedure : -
  • Maximum Diameter (mm) : 6
  • Unrestrained Coil Length (mm) : 6.5
  • Length in Introducer (mm) : 85
device-thumbnail
VortX 35
  • Model : M0013732041
  • Procedure : -
  • Maximum Diameter (mm) : 4
  • Unrestrained Coil Length (mm) : 4
  • Length in Introducer (mm) : 30
device-thumbnail
VortX 35
  • Model : M0013733051
  • Procedure : -
  • Maximum Diameter (mm) : 5
  • Unrestrained Coil Length (mm) : 4.5
  • Length in Introducer (mm) : 35
device-thumbnail
VortX 35
  • Model : M0013733061
  • Procedure : -
  • Maximum Diameter (mm) : 6
  • Unrestrained Coil Length (mm) : 5
  • Length in Introducer (mm) : 53
device-thumbnail
VortX 35
  • Model : M0013733071
  • Procedure : -
  • Maximum Diameter (mm) : 7
  • Unrestrained Coil Length (mm) : 5.5
  • Length in Introducer (mm) : 67
device-thumbnail
VortX Diamond 18
  • Model : M0013822031
  • Procedure : -
  • Maximum Diameter (mm) : 3
  • Unrestrained Coil Length (mm) : 3.3
  • Length in Introducer (mm) : 23
device-thumbnail
VortX Diamond 18
  • Model : M0013822041
  • Procedure : -
  • Maximum Diameter (mm) : 4
  • Unrestrained Coil Length (mm) : 3.7
  • Length in Introducer (mm) : 41
device-thumbnail
VortX Diamond 18
  • Model : M0013822051
  • Procedure : -
  • Maximum Diameter (mm) : 5
  • Unrestrained Coil Length (mm) : 5.5
  • Length in Introducer (mm) : 58
device-thumbnail
VortX Diamond 18
  • Model : M0013822061
  • Procedure : -
  • Maximum Diameter (mm) : 6
  • Unrestrained Coil Length (mm) : 6.7
  • Length in Introducer (mm) : 80

Questions & Answers

Don't see the answer you're looking for ?