Manufacturer > Abbott > Devices > RX ACCUNET EMBOLIC PROTECTION SYSTEM

RX ACCUNET EMBOLIC PROTECTION SYSTEM

Device-Type

Embolic Protection

Targated Speciality

Cardiovascular

Manufacturer

Abbott


The Accunet Embolic Protection System is a fixed-wire filter designed to provide capture capabilities during carotid stenting interventions. The Balance Heavyweight Guide Wire and delivery sheath enter the vessel as one unit, with the ability to torque the wire independent of the filter basket.

Features and Benefits

Deliverability

  • Guide wire and delivery sheath enter vessel as one unit
  • Flexible to navigate tortuous anatomy
  • Low profile and smooth transition from tip to filter basket
  • .014" wire can be torqued independent from filter basket


product


Peel away Convertible Sheath

 

Deployment

  • Rapid exchange unsheathing for stability and simplicity
  • Peel away delivery sheath allows for controlled deployment


product

Effective and Flexible Filter

 

Capture and Control

  • Flexible filter basket designed to conform to tortuosity
  • Designed to capture high volume emboli while allowing adequate blood flow
  • Concentric design with guide wire centered in filter
  • Four platinum radiopaque markers surround filter for visualization of wall apposition


product

Shapeable Recovery Catheter Tip

 

Filter Retrieval

Choice of two rapid exchange recovery catheters designed specifically for the challenges of filter recovery.

RX Accunet Recovery Catheter

  • Shapeable distal tip steers catheter from stent struts during advancement
  • Filter basket secured with all cage strut openings enclosed during withdrawal


product


Flexible Recovery Catheter Tip

 

RX Accunet 2 Recovery Catheter

  • Low-profile, flexible tip to allow for deflection away from stent struts during advancement
  • Flexible catheter/shaft optimized for challenging guide catheter/sheath access
  • Catheter shaft markers at 95 and 105 cm for reduced flouro time

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Guide Wire Length Filter Size Fully Expanded (mm) Reference Vessel Diameter Minimum to Maximum Range (mm) Minimum Sheath Size (F) Minimum Guiding Catheter Size (F)
RX ACCUNET EMBOLIC PROTECTION SYSTEM
1011651-45 190 (cm) 4.5 3.25 - 4.0 6F 8F
RX ACCUNET EMBOLIC PROTECTION SYSTEM
1011651-55 190 (cm) 5.5 4.0 - 5.0 6F 8F
RX ACCUNET EMBOLIC PROTECTION SYSTEM
1011651-65 190 (cm) 6.5 5.0 - 6.0 6F 8F
RX ACCUNET EMBOLIC PROTECTION SYSTEM
1011651-75 190 (cm) 7.5 6.0 - 7.0 6F 8F
RX ACCUNET EMBOLIC PROTECTION SYSTEM
1011652-45 300 (cm) 4.5 3.25 - 4.0 6F 8F
RX ACCUNET EMBOLIC PROTECTION SYSTEM
1011652-55 300 (cm) 5.5 4.0 - 5.0 6F 8F
RX ACCUNET EMBOLIC PROTECTION SYSTEM
1011652-65 300 (cm) 6.5 5.0 - 6.0 6F 8F
RX ACCUNET EMBOLIC PROTECTION SYSTEM
1011652-75 300 (cm) 7.5 6.0 - 7.0 6F 8F
  • Model : 1011651-45
  • Procedure : -
  • Guide Wire Length : 190 (cm)
  • Filter Size Fully Expanded (mm) : 4.5
  • Reference Vessel Diameter Minimum to Maximum Range (mm) : 3.25 - 4.0
  • Minimum Sheath Size (F) : 6F
  • Minimum Guiding Catheter Size (F) : 8F
  • Model : 1011651-55
  • Procedure : -
  • Guide Wire Length : 190 (cm)
  • Filter Size Fully Expanded (mm) : 5.5
  • Reference Vessel Diameter Minimum to Maximum Range (mm) : 4.0 - 5.0
  • Minimum Sheath Size (F) : 6F
  • Minimum Guiding Catheter Size (F) : 8F
  • Model : 1011651-65
  • Procedure : -
  • Guide Wire Length : 190 (cm)
  • Filter Size Fully Expanded (mm) : 6.5
  • Reference Vessel Diameter Minimum to Maximum Range (mm) : 5.0 - 6.0
  • Minimum Sheath Size (F) : 6F
  • Minimum Guiding Catheter Size (F) : 8F
  • Model : 1011651-75
  • Procedure : -
  • Guide Wire Length : 190 (cm)
  • Filter Size Fully Expanded (mm) : 7.5
  • Reference Vessel Diameter Minimum to Maximum Range (mm) : 6.0 - 7.0
  • Minimum Sheath Size (F) : 6F
  • Minimum Guiding Catheter Size (F) : 8F
  • Model : 1011652-45
  • Procedure : -
  • Guide Wire Length : 300 (cm)
  • Filter Size Fully Expanded (mm) : 4.5
  • Reference Vessel Diameter Minimum to Maximum Range (mm) : 3.25 - 4.0
  • Minimum Sheath Size (F) : 6F
  • Minimum Guiding Catheter Size (F) : 8F
  • Model : 1011652-55
  • Procedure : -
  • Guide Wire Length : 300 (cm)
  • Filter Size Fully Expanded (mm) : 5.5
  • Reference Vessel Diameter Minimum to Maximum Range (mm) : 4.0 - 5.0
  • Minimum Sheath Size (F) : 6F
  • Minimum Guiding Catheter Size (F) : 8F
  • Model : 1011652-65
  • Procedure : -
  • Guide Wire Length : 300 (cm)
  • Filter Size Fully Expanded (mm) : 6.5
  • Reference Vessel Diameter Minimum to Maximum Range (mm) : 5.0 - 6.0
  • Minimum Sheath Size (F) : 6F
  • Minimum Guiding Catheter Size (F) : 8F
  • Model : 1011652-75
  • Procedure : -
  • Guide Wire Length : 300 (cm)
  • Filter Size Fully Expanded (mm) : 7.5
  • Reference Vessel Diameter Minimum to Maximum Range (mm) : 6.0 - 7.0
  • Minimum Sheath Size (F) : 6F
  • Minimum Guiding Catheter Size (F) : 8F

Questions & Answers