Manufacturer > Medtronic > Devices > SilverHawk Peripheral Plaque Excision System

SilverHawk Peripheral Plaque Excision System

Device-Type

Atherectomy Devices

Targated Speciality

Atherectomy

Manufacturer

Medtronic


Preserve the native vessel and keep future treatment options open for PAD patients when you treat with the SilverHawk™ peripheral plaque excision system. Use the device's directional cutter to shave soft-to-mild plaque, while the nosecone captures the material for removal from the artery. The SilverHawk technology is backed by the landmark DEFINITIVE LE clinical study, which found that PAD patients with critical limb ischemia who were treated with plaque excision experienced a high rate (95%) of limb salvage at 12 months.


The SilverHawk™ Peripheral Plaque Excision System is intended for use in atherectomy of the peripheral vasculature. The catheter is NOT intended for use in the coronary, carotid, iliac or renal vasculature.

Features and Benefits

The SilverHawk peripheral plaque excision system treats peripheral arterial disease (PAD) by removing plaque from blocked arteries. Unlike other methods of restoring blood flow, the SilverHawk device removes the obstruction—plaque build-up—instead of simply compressing it against the vessel wall. Directional atherectomy with the SilverHawk device enables physicians to maximize lumen gain and minimize barotrauma without leaving any implant behind. This allows preservation of the native vessel and future treatment options.

  • Treats peripheral arterial disease by removing the disease with directional atherectomy technology.
  • Uses a directional cutting blade to shave plaque from the vessel to maximize luminal gain.
  • Captures plaque in a nosecone so that the plaque can be removed from the vessel.
  • Can be used above or below the knee.
  • Backed by the landmark DEFINITIVE LE clinical study.

SilverHawk nosecone

Safety informations

Indications for Use: 

The SilverHawk™ peripheral plaque excision system is intended for use in atherectomy of the peripheral vasculature. The catheter is NOT intended for use in the coronary, carotid, iliac or renal vasculature.

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Vessel Diameter(mm) Sheath Compatibility(F) Crossing Profile(mm) Working Length(cm) Effective Length(cm) Tip Length(cm) Max. Cut Length(cm)
DS
P4028 1.5-2.0 6 1.9 135 132 2.6 10
EXL
P4044 2.0-3.0 6 2 135 129 6 15
LX-M
P4055 4.5-6.5 7/8 2.7 113 104 9 75
MS-M
P4056 3.5-5.0 7/8 2.7 110 104 6 50
SS+
P4030 3.0-3.5 7 2.3 135 132 2.6 15
device-thumbnail
DS
  • Model : P4028
  • Procedure : -
  • Vessel Diameter(mm) : 1.5-2.0
  • Sheath Compatibility(F) : 6
  • Crossing Profile(mm) : 1.9
  • Working Length(cm) : 135
  • Effective Length(cm) : 132
  • Tip Length(cm) : 2.6
  • Max. Cut Length(cm) : 10
device-thumbnail
EXL
  • Model : P4044
  • Procedure : -
  • Vessel Diameter(mm) : 2.0-3.0
  • Sheath Compatibility(F) : 6
  • Crossing Profile(mm) : 2
  • Working Length(cm) : 135
  • Effective Length(cm) : 129
  • Tip Length(cm) : 6
  • Max. Cut Length(cm) : 15
device-thumbnail
LX-M
  • Model : P4055
  • Procedure : -
  • Vessel Diameter(mm) : 4.5-6.5
  • Sheath Compatibility(F) : 7/8
  • Crossing Profile(mm) : 2.7
  • Working Length(cm) : 113
  • Effective Length(cm) : 104
  • Tip Length(cm) : 9
  • Max. Cut Length(cm) : 75
device-thumbnail
MS-M
  • Model : P4056
  • Procedure : -
  • Vessel Diameter(mm) : 3.5-5.0
  • Sheath Compatibility(F) : 7/8
  • Crossing Profile(mm) : 2.7
  • Working Length(cm) : 110
  • Effective Length(cm) : 104
  • Tip Length(cm) : 6
  • Max. Cut Length(cm) : 50
device-thumbnail
SS+
  • Model : P4030
  • Procedure : -
  • Vessel Diameter(mm) : 3.0-3.5
  • Sheath Compatibility(F) : 7
  • Crossing Profile(mm) : 2.3
  • Working Length(cm) : 135
  • Effective Length(cm) : 132
  • Tip Length(cm) : 2.6
  • Max. Cut Length(cm) : 15