Manufacturer > Reflow Medical > Devices > Spex35 Shapeable Support Catheter

Spex35 Shapeable Support Catheter

Device-Type

Angiographic Catheters

Targated Speciality

Cardiovascular

Manufacturer

Reflow Medical


CUSTOMIZABLE TIP MAINTAINS THE DESIRED ANGLE

Allows the physician to shape to the preferred angle and holds it throughout the procedure


COMPATIBLE WITH YOUR PREFERRED GUIDEWIRE & PROCEDURAL TECHNIQUE

Works with the Reflow Wingman™ Catheter for added support in lesion crossing

Features and Benefits

  • Compatible with the physician’s preferred guide wire and procedural technique.
  • Combine with the Reflow Wingman™ Crossing Catheter to optimize support.
  • Use the Spex 35 Support Catheter with the Reflow SpexLP™



ACCESS FROM ANGLES

  • Promotes improved and predictable access to the vasculature.
  • Designed to fill a specific need based on clinical feedback.
  • Allows the physician to straighten or reshape the angle as needed.
  • Helps the physician perform procedures more effectively.
  • Increases lubricity with a seamless, low-profile hydrophilic coating.
  • Optimizes pushability and access through lesions

Safety informations

INTENDED USE/INDICATIONS FOR USE

The Spex Support Catheter is intended to facilitate placement and support of guidewires and other interventional devices within the peripheral vasculature and to allow for exchange of guidewires, and provide a conduit for the delivery of saline or contrast solutions.

CONTRAINDICATIONS

None known

WARNINGS

  • The catheter is designed and intended for intravascular use only.
  • This catheter is designed and intended for one time use only. Do not re-sterilize and/or reuse.
  • This catheter should only be used by physicians qualified to perform percutaneous, vascular interventions.
  • These catheters are not designed for use in the coronary arteries or the neurovasculature. Any use for procedures other than those indicated in the instructions is not recommended.

PRECAUTIONS

  • Support Catheters are designed for use by physicians engaged in the practice of a specialized branch of medicine. Use of these devices should be restricted to those specialists trained to perform the procedure. A thorough understanding of the technical principles, clinical applications and risks associated with support catheters is necessary before performing this procedure.
  • Precautions to prevent or reduce clotting should be taken when any catheter is used. Use of systemic heparinization should be considered.


Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Effective Length (cm) Guidewire Compatability (in) Max Outer Diameter (in/F) Max Pressure (psi/kpa) Shapeable Tip Zone (in/mm) Sheath Compatibility (F/mm) Hydrophilic Coating (cm)
Spex35 Shapeable Support Catheter
SPX35050 50 0.035 0.06/4.6 300/2068 .75/19 5/1.7 40
Spex35 Shapeable Support Catheter
SPX35090 90 0.035 0.06/4.6 300/2068 .75/19 5/1.7 40
Spex35 Shapeable Support Catheter
SPX35135 135 0.035 0.06/4.6 300/2068 .75/19 5/1.7 40
Spex35 Shapeable Support Catheter
SPX35150 150 0.035 0.06/4.6 300/2068 .75/19 5/1.7 40
  • Model : SPX35050
  • Procedure : -
  • Effective Length (cm) : 50
  • Guidewire Compatability (in) : 0.035
  • Max Outer Diameter (in/F) : 0.06/4.6
  • Max Pressure (psi/kpa) : 300/2068
  • Shapeable Tip Zone (in/mm) : .75/19
  • Sheath Compatibility (F/mm) : 5/1.7
  • Hydrophilic Coating (cm) : 40
  • Model : SPX35090
  • Procedure : -
  • Effective Length (cm) : 90
  • Guidewire Compatability (in) : 0.035
  • Max Outer Diameter (in/F) : 0.06/4.6
  • Max Pressure (psi/kpa) : 300/2068
  • Shapeable Tip Zone (in/mm) : .75/19
  • Sheath Compatibility (F/mm) : 5/1.7
  • Hydrophilic Coating (cm) : 40
  • Model : SPX35135
  • Procedure : -
  • Effective Length (cm) : 135
  • Guidewire Compatability (in) : 0.035
  • Max Outer Diameter (in/F) : 0.06/4.6
  • Max Pressure (psi/kpa) : 300/2068
  • Shapeable Tip Zone (in/mm) : .75/19
  • Sheath Compatibility (F/mm) : 5/1.7
  • Hydrophilic Coating (cm) : 40
  • Model : SPX35150
  • Procedure : -
  • Effective Length (cm) : 150
  • Guidewire Compatability (in) : 0.035
  • Max Outer Diameter (in/F) : 0.06/4.6
  • Max Pressure (psi/kpa) : 300/2068
  • Shapeable Tip Zone (in/mm) : .75/19
  • Sheath Compatibility (F/mm) : 5/1.7
  • Hydrophilic Coating (cm) : 40