Manufacturer > Medtronic > Devices > TrailBlazer Support Catheters

TrailBlazer Support Catheters

Device-Type

Specialty Catheters

Manufacturer

Medtronic


Access and cross lesions in the peripheral vessels with the TrailBlazer™ support catheter and the TrailBlazer™ angled support catheter. Use the support catheter to access and track through a vessel, enable guidewire exchanges and to deliver saline or contrast during endovascular procedures. Use the angled version of this support catheter to direct to desired location; the braided shaft provides extra support when needed.



TrailBlazer™ Support Catheter are percutaneous, single lumen catheters designed for use in the peripheral vascular system. TrailBlazer™ Support Catheters are intended to guide and support a guide wire during access of the vasculature, allow for wire exchanges and provide a conduit for the delivery of saline solutions or diagnostic contrast agents.

TrailBlazer™ Angled Support Catheters are percutaneous, single lumen catheters designed for use in the peripheral vascular system. TrailBlazer™ Support Catheters are intended to guide and support a guide wire during access of the vasculature, allow for wire exchanges and provide a conduit for the delivery of saline solutions or diagnostic contrast agents.

Features and Benefits

TRAILBLAZER SUPPORT CATHETER

  • Nonbraided catheter offers enhanced tracking and efficient crossing.
  • Translucent shaft allows visualization of catheter.
  • Straight tip design.

TrailBlazer support catheter

TRAILBLAZER ANGLED SUPPORT CATHETER

  • Braided catheter provides robust pushability to cross through tough lesions.
  • Angled 25 and 30 degree tips facilitate vessel selection and crossing.
  • Telescoping enables 0.014' and 0.018' angled catheter to be placed through 0.035' catheter for extended reach and pushability.

TrailBlazer angled support catheter

Design of TrailBlazer Support Catheters  

Design features of both the TrailBlazer support catheter (top) and TrailBlazer angled support catheter (bottom).

  1. Hydrophilic coating (distal 40cm) provides lubricity.
  2. Embedded marker bands aid catheter positioning.
  3. Tapered, low profile tip enables crossing.

Safety informations

TrailBlazer™ Support Catheter

Indications for Use: TrailBlazer™ Support Catheter are percutaneous, single lumen catheters designed for use in the peripheral vascular system. TrailBlazer™ Support Catheters are intended to guide and support a guide wire during access of the vasculature, allow for wire exchanges and provide a conduit for the delivery of saline solutions or diagnostic contrast agents.

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Markerband Space (mm) Minimum Introducer Sheath (F) Minimum Guide Sheath (F) Guidewire Length (cm)
TRAILBLAZER SUPPORT CATHETER
SC-035-065 50 5 6 0.035" 65
TRAILBLAZER SUPPORT CATHETER
SC-018-090 15 5 6 0.018" 90
TRAILBLAZER SUPPORT CATHETER
SC-035-090 50 5 6 0.035" 90
TRAILBLAZER SUPPORT CATHETER
SC-035-135 50 5 6 0.035" 135
TRAILBLAZER SUPPORT CATHETER
SC-018-135 15 4 5 0.018" 135
TRAILBLAZER SUPPORT CATHETER
SC-014-135 15 4 5 0.014" 135
TRAILBLAZER SUPPORT CATHETER
SC-014-150 15 4 5 0.014" 150 cm
TRAILBLAZER SUPPORT CATHETER
SC-018-150 15 4 5 0.018" 150 cm
TRAILBLAZER SUPPORT CATHETER
SC-035-150 50 5 6 0.035" 150 cm
  • Model : SC-035-065
  • Procedure : -
  • Markerband Space (mm) : 50
  • Minimum Introducer Sheath (F) : 5
  • Minimum Guide Sheath (F) : 6
  • Guidewire : 0.035"
  • Length (cm) : 65
  • Model : SC-018-090
  • Procedure : -
  • Markerband Space (mm) : 15
  • Minimum Introducer Sheath (F) : 5
  • Minimum Guide Sheath (F) : 6
  • Guidewire : 0.018"
  • Length (cm) : 90
  • Model : SC-035-090
  • Procedure : -
  • Markerband Space (mm) : 50
  • Minimum Introducer Sheath (F) : 5
  • Minimum Guide Sheath (F) : 6
  • Guidewire : 0.035"
  • Length (cm) : 90
  • Model : SC-035-135
  • Procedure : -
  • Markerband Space (mm) : 50
  • Minimum Introducer Sheath (F) : 5
  • Minimum Guide Sheath (F) : 6
  • Guidewire : 0.035"
  • Length (cm) : 135
  • Model : SC-018-135
  • Procedure : -
  • Markerband Space (mm) : 15
  • Minimum Introducer Sheath (F) : 4
  • Minimum Guide Sheath (F) : 5
  • Guidewire : 0.018"
  • Length (cm) : 135
  • Model : SC-014-135
  • Procedure : -
  • Markerband Space (mm) : 15
  • Minimum Introducer Sheath (F) : 4
  • Minimum Guide Sheath (F) : 5
  • Guidewire : 0.014"
  • Length (cm) : 135
  • Model : SC-014-150
  • Procedure : -
  • Markerband Space (mm) : 15
  • Minimum Introducer Sheath (F) : 4
  • Minimum Guide Sheath (F) : 5
  • Guidewire : 0.014"
  • Length (cm) : 150 cm
  • Model : SC-018-150
  • Procedure : -
  • Markerband Space (mm) : 15
  • Minimum Introducer Sheath (F) : 4
  • Minimum Guide Sheath (F) : 5
  • Guidewire : 0.018"
  • Length (cm) : 150 cm
  • Model : SC-035-150
  • Procedure : -
  • Markerband Space (mm) : 50
  • Minimum Introducer Sheath (F) : 5
  • Minimum Guide Sheath (F) : 6
  • Guidewire : 0.035"
  • Length (cm) : 150 cm

Questions & Answers

Don't see the answer you're looking for ?