Manufacturer > MedComp > Devices > TRI-FLOW® SHORT TERM HEMODIALYSIS CATHETERS

TRI-FLOW® SHORT TERM HEMODIALYSIS CATHETERS

Device-Type

Dialysis Catheter

Manufacturer

MedComp


The 12F Tri-Flow Triple Lumen Catheter is a short term dialysis catheter made of thermosensitive polyurethane. The catheter has three separate lumens allowing continuous blood flow. The venous (blue) and arterial (red) lumens may be used for hemodialysis and apheresis treatments. The middle (clear) lumen is independent from the two dialysis lumens and may be used for intravenous therapy, blood draws and infusion of medications.

Features and Benefits

  • Ideal for extracorporeal therapies: dialysis, hemofiltration, apheresis and plasmapheresis.
  • Third lumen gives greater flexibility for fluid administration, vasoactive drug therapy, nutrition and blood sampling.
  • MRI SAFE.


Safety informations

INDICATIONS FOR USE: 

The 12F Tri-Flow Triple Lumen Catheter is indicated for use in attaining Short-Term vascular access for Hemodialysis and Apheresis. It may be inserted percutaneously and is primarily placed in the internal jugular vein of an adult patient. Alternate insertion sites include subclavian vein or femoral vein as required. The 12F Tri-Flow Triple Lumen Catheter is intended to be used less than (30) days.


CONTRAINDICATIONS

This catheter is intended for Short-Term vascular access only and should not be used for any purpose other than indicated in these instructions. Do not insert catheter in thrombosed vessels.

Potential adverse events

• Air Embolism

• Bacteremia

• Brachial Plexus Injury

• Cardiac Arrhythmia

• Cardiac Tamponade

• Central Venous Thrombosis

• Endocarditis

• Exit Site Infection

• Exsanguination

• Femoral Artery Bleed

• Femoral Nerve Damage

• Hematoma

• Hemorrhage

• Hemothorax

• Inferior Vena Cava Puncture

• Laceration of the Vessel

• Lumen Thrombosis

• Mediastinal Injury

• Perforation of the Vessel

• Pleural Injury

• Pneumothorax

• Retroperitoneal Bleed

• Right Atrial Puncture

• Septicemia

• Subclavian Artery Puncture

• Subcutaneous Hematoma

• Superior Vena Cava Puncture

• Thoracic Duct Laceration

• Vascular Thrombos

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Size(f) Length(cm) Configuration
TRI-FLOW
AS0212151 12 15 Straight
TRI-FLOW
AS0212201 12 20 Straight
TRI-FLOW
AS0212241 12 24 Straight
TRI-FLOW
AC0212151 12 15 Curved Extensions
TRI-FLOW
AC0212201 12 20 Curved Extensions
device-thumbnail
TRI-FLOW
  • Model : AS0212151
  • Procedure : -
  • Size(f) : 12
  • Length(cm) : 15
  • Configuration : Straight
device-thumbnail
TRI-FLOW
  • Model : AS0212201
  • Procedure : -
  • Size(f) : 12
  • Length(cm) : 20
  • Configuration : Straight
device-thumbnail
TRI-FLOW
  • Model : AS0212241
  • Procedure : -
  • Size(f) : 12
  • Length(cm) : 24
  • Configuration : Straight
device-thumbnail
TRI-FLOW
  • Model : AC0212151
  • Procedure : -
  • Size(f) : 12
  • Length(cm) : 15
  • Configuration : Curved Extensions
device-thumbnail
TRI-FLOW
  • Model : AC0212201
  • Procedure : -
  • Size(f) : 12
  • Length(cm) : 20
  • Configuration : Curved Extensions

Questions & Answers