The unique 2.0 F design and 0.021” inner diameter lets you go further, without sacrificing the superior flow rates and embolic compatibility you need.


TruSelect™ Microcatheters are designed for interventionalists. Engineered with an 0.021" inner diameter within a 2.0 F design and the first 175 cm length, with a balance of pushability and flexibility providing enhanced trackability, TruSelect Microcatheters allow interventionalists to get closer to intended targets without sacrificing flow rates or embolic choices.

Features and Benefits

Selective Embolization You Control

TruSelect™ Microcatheters are designed for interventionalists. Engineered with an 0.021” inner diameter within a 2.0 F design and the first 175 cm length, with a balance of pushability and flexibility providing enhanced trackability, TruSelect Microcatheters allow interventionalists to get closer to intended targets without sacrificing flow rates or embolic choices.

Diameter

High Flow Rates

Higher

Flow Rates

TruSelect provides flow rates comparable to conventional 2.4 F microcatheters*, maintaining visualization even in small distal anatomy.

More Embolic Compatibility

More Embolic Compatibility

TruSelect is compatible with all 0.018” coils, spherical embolics up to 700 μm and Y-90 products, including TheraSphere™.

 

Extended Radial Lengths

Extended

Radial Lengths

TruSelect introduces the first ever 175 cm length microcatheter, ideal for radial access.

Truselect Enhanced Trackability

Enhanced Trackability

TruSelect is designed with a balance of pushability and flexibility for tracking through tortuous anatomy.

Use Case Examples

TruSelect Microcatheter Live Case Recording


See Sandeep Bagla, MD and Ari Isaacson, MD perform and discuss using a TruSelect Microcatheter for a Prostate Artery Embolization (PAE) procedure from radial access.

Safety informations

CAUTION: Federal law (USA) restricts this device to sale by or on the order of a physician. Rx only. Prior to use, please see the complete “Instructions for Use” for more information on Indications, Contraindications, Warnings, Precautions, Adverse Events, and Operator’s Instructions.


INTENDED USE: The TRUSELECT Microcatheters are intended for peripheral vascular use. The microcatheter can be used for selective infusion of diagnostic, embolic, or therapeutic materials into the vessel. CONTRAINDICATIONS: None known.


WARNINGS:

• Never advance or withdraw an intravascular device against resistance until the cause of resistance is determined by fluoroscopy. Movement of the microcatheter or guidewire against resistance may result in damage or separation of the microcatheter or guidewire tip, or vessel perforation.

• TRUSELECT™ Microcatheter is not intended for use in the coronary vasculature or neurovasculature.


PRECAUTIONS:

• This device should be used only by physicians thoroughly trained in percutaneous, intravascular techniques and procedures.

• Diagnostic, embolic, or therapeutic agents are to be used in accordance with specifications outlined by the manufacturer.

• Because the microcatheter may be advanced into narrow sub-selective vasculature, repeatedly assure that the microcatheter has not been advanced so far as to interfere with its removal.

Potential adverse events

The Adverse Events include, but are not limited to: • Allergic reaction (to drug, contrast, device or other) • Cerebrovascular accident (CVA), stroke, transient ischemic attack (TIA) • Death • Embolism (air, plaque, thrombus, device or other) • Hemorrhage/Hematoma • Infection/sepsis • Need for urgent intervention or surgery • Thrombus/thrombosis • Vasospasm • Vessel occlusion • Vessel trauma (perforation, injury, rupture, dissection, pseudoaneurysm)

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Usable Length (cm) Proximal/distal O.D. (F) Inner Diameter (in) Tip Shape Max Burst Rating (PSI)
TruSelect Microcatheter
M001394101050 105 2.8/2.0 0.021" Straight 800
TruSelect Microcatheter
M001394101300 130 2.8/2.0 0.021" Straight 800
TruSelect Microcatheter
M001394101550 155 2.8/2.0 0.021" Straight 800
TruSelect Microcatheter
M001394101750 175 2.8/2.0 0.021" Straight 800
TruSelect Microcatheter
M001394111050 105 2.8/2.0 0.021" Bern 800
TruSelect Microcatheter
M001394111300 130 2.8/2.0 0.021" Bern 800
TruSelect Microcatheter
M001394111550 155 2.8/2.0 0.021" Bern 800
TruSelect Microcatheter
M001394111750 175 2.8/2.0 0.021" Bern 800
  • Model : M001394101050
  • Procedure : -
  • Usable Length (cm) : 105
  • Proximal/distal O.D. (F) : 2.8/2.0
  • Inner Diameter (in) : 0.021"
  • Tip Shape : Straight
  • Max Burst Rating (PSI) : 800
  • Model : M001394101300
  • Procedure : -
  • Usable Length (cm) : 130
  • Proximal/distal O.D. (F) : 2.8/2.0
  • Inner Diameter (in) : 0.021"
  • Tip Shape : Straight
  • Max Burst Rating (PSI) : 800
  • Model : M001394101550
  • Procedure : -
  • Usable Length (cm) : 155
  • Proximal/distal O.D. (F) : 2.8/2.0
  • Inner Diameter (in) : 0.021"
  • Tip Shape : Straight
  • Max Burst Rating (PSI) : 800
  • Model : M001394101750
  • Procedure : -
  • Usable Length (cm) : 175
  • Proximal/distal O.D. (F) : 2.8/2.0
  • Inner Diameter (in) : 0.021"
  • Tip Shape : Straight
  • Max Burst Rating (PSI) : 800
  • Model : M001394111050
  • Procedure : -
  • Usable Length (cm) : 105
  • Proximal/distal O.D. (F) : 2.8/2.0
  • Inner Diameter (in) : 0.021"
  • Tip Shape : Bern
  • Max Burst Rating (PSI) : 800
  • Model : M001394111300
  • Procedure : -
  • Usable Length (cm) : 130
  • Proximal/distal O.D. (F) : 2.8/2.0
  • Inner Diameter (in) : 0.021"
  • Tip Shape : Bern
  • Max Burst Rating (PSI) : 800
  • Model : M001394111550
  • Procedure : -
  • Usable Length (cm) : 155
  • Proximal/distal O.D. (F) : 2.8/2.0
  • Inner Diameter (in) : 0.021"
  • Tip Shape : Bern
  • Max Burst Rating (PSI) : 800
  • Model : M001394111750
  • Procedure : -
  • Usable Length (cm) : 175
  • Proximal/distal O.D. (F) : 2.8/2.0
  • Inner Diameter (in) : 0.021"
  • Tip Shape : Bern
  • Max Burst Rating (PSI) : 800