Manufacturer > Philips > Devices > Turbo-Elite Laser atherectomy catheter

Turbo-Elite Laser atherectomy catheter

Device-Type

Atherectomy Devices

Targated Speciality

Atherectomy

Manufacturer

Philips


Turbo-Elite laser atherectomy catheter captures the power of ultraviolet light to provide a versatile and reliable tool for treating multiple lesion morphologies within PAD lesions. Utilizing laser's unique mechanism of action, Turbo-Elite is capable of powering through the most challenging restenoses and occlusions.

Features and Benefits

Versatile performance

Turbo-Elite uniformly and reliably helps treat a variety of morphologies and locations with a single catheter.

Cross and debulk with one device

The safe and proven step-by-step method crosses and prepares challenging occlusions without a wire by acting directly from the catheter’s tip.

Reliably simple

With its safe and easy-to-use technology, Turbo-Elite provides laser-accurate control with none of the moving parts or cutting blades of competing atherectomy catheters.

Strong clinical support

Turbo-Elite has a proven record of safety and effectiveness with results that consistently demonstrate an ability to save limbs and treat lesions both above and below the knee.

Cost-effective solution

Through a single device that can both cross and debulk a lesion, Turbo-Elite provides you with clinical efficacy and reliability at a lower cost per case than other technologies.


Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Catheter Diamter(mm) Vessel Diameter(mm) Max Guidewire Compatibility Sheath Compatibility(F) Max tip outer diameter Max shaft outer diameter Working length(cm) Fluence (mJ/mm2) Repetition rate (Hz)
Peripheral over-the wire (OTW) catheters
410-152 9 ≥1.4 0.014” 4 0.038” 0.047” 150 30-80 25-80
Peripheral over-the wire (OTW) catheters
414-151 1.4 ≥2.1 0.014” 5 0.055” 0.056” 150 30-60 25-80
Peripheral over-the wire (OTW) catheters
417-152 1.7 ≥2.6 0.018" 5 0.068” 0.069” 150 30-60 25-81
Peripheral over-the wire (OTW) catheters
420-006 2 ≥3.0 0.018" 6 0.080” 0.081” 150 30-61 25-82
Peripheral over-the wire (OTW) catheters
423-001 2.3 ≥3.5 0.018" 7 0.091” 0.091” 120 30-62 25-83
Peripheral over-the wire (OTW) catheters
425-011 2.5 ≥3.8 0.018" 8 0.101” 0.102” 110 30-45 25-84
Peripheral over-the wire (OTW) catheters
423-135 2.3 ≥3.5 0.035” 7 0.091” 0.091” 125 30-60 25-85
Peripheral over-the wire (OTW) catheters
425-135 2.5 ≥3.8 0.035” 8 0.101” 0.102” 112 30-60 25-86
  • Model : 410-152
  • Procedure : -
  • Catheter Diamter(mm) : 9
  • Vessel Diameter(mm) : ≥1.4
  • Max Guidewire Compatibility : 0.014”
  • Sheath Compatibility(F) : 4
  • Max tip outer diameter : 0.038”
  • Max shaft outer diameter : 0.047”
  • Working length(cm) : 150
  • Fluence (mJ/mm2) : 30-80
  • Repetition rate (Hz) : 25-80
  • Model : 414-151
  • Procedure : -
  • Catheter Diamter(mm) : 1.4
  • Vessel Diameter(mm) : ≥2.1
  • Max Guidewire Compatibility : 0.014”
  • Sheath Compatibility(F) : 5
  • Max tip outer diameter : 0.055”
  • Max shaft outer diameter : 0.056”
  • Working length(cm) : 150
  • Fluence (mJ/mm2) : 30-60
  • Repetition rate (Hz) : 25-80
  • Model : 417-152
  • Procedure : -
  • Catheter Diamter(mm) : 1.7
  • Vessel Diameter(mm) : ≥2.6
  • Max Guidewire Compatibility : 0.018"
  • Sheath Compatibility(F) : 5
  • Max tip outer diameter : 0.068”
  • Max shaft outer diameter : 0.069”
  • Working length(cm) : 150
  • Fluence (mJ/mm2) : 30-60
  • Repetition rate (Hz) : 25-81
  • Model : 420-006
  • Procedure : -
  • Catheter Diamter(mm) : 2
  • Vessel Diameter(mm) : ≥3.0
  • Max Guidewire Compatibility : 0.018"
  • Sheath Compatibility(F) : 6
  • Max tip outer diameter : 0.080”
  • Max shaft outer diameter : 0.081”
  • Working length(cm) : 150
  • Fluence (mJ/mm2) : 30-61
  • Repetition rate (Hz) : 25-82
  • Model : 423-001
  • Procedure : -
  • Catheter Diamter(mm) : 2.3
  • Vessel Diameter(mm) : ≥3.5
  • Max Guidewire Compatibility : 0.018"
  • Sheath Compatibility(F) : 7
  • Max tip outer diameter : 0.091”
  • Max shaft outer diameter : 0.091”
  • Working length(cm) : 120
  • Fluence (mJ/mm2) : 30-62
  • Repetition rate (Hz) : 25-83
  • Model : 425-011
  • Procedure : -
  • Catheter Diamter(mm) : 2.5
  • Vessel Diameter(mm) : ≥3.8
  • Max Guidewire Compatibility : 0.018"
  • Sheath Compatibility(F) : 8
  • Max tip outer diameter : 0.101”
  • Max shaft outer diameter : 0.102”
  • Working length(cm) : 110
  • Fluence (mJ/mm2) : 30-45
  • Repetition rate (Hz) : 25-84
  • Model : 423-135
  • Procedure : -
  • Catheter Diamter(mm) : 2.3
  • Vessel Diameter(mm) : ≥3.5
  • Max Guidewire Compatibility : 0.035”
  • Sheath Compatibility(F) : 7
  • Max tip outer diameter : 0.091”
  • Max shaft outer diameter : 0.091”
  • Working length(cm) : 125
  • Fluence (mJ/mm2) : 30-60
  • Repetition rate (Hz) : 25-85
  • Model : 425-135
  • Procedure : -
  • Catheter Diamter(mm) : 2.5
  • Vessel Diameter(mm) : ≥3.8
  • Max Guidewire Compatibility : 0.035”
  • Sheath Compatibility(F) : 8
  • Max tip outer diameter : 0.101”
  • Max shaft outer diameter : 0.102”
  • Working length(cm) : 112
  • Fluence (mJ/mm2) : 30-60
  • Repetition rate (Hz) : 25-86

Questions & Answers