Manufacturer > Angiodynamics > Devices > Uni-Fuse™ Infusion Catheter

Uni-Fuse™ Infusion Catheter

Device-Type

Infusion System

Manufacturer

Angiodynamics


Catheter Directed Thrombolysis (CDT) offers many advantages over alternative treatments and is a viable option for managing thrombus. For over 20 years AngioDynamics has been the market leader for CDT catheters with its innovative slit technology to infuse a consistent, even distribution of lytic agent to an area of clot. The Uni*Fuse catheter uses this time-tested technology to provide faster and more effective treatment for clots, and its sturdier construction makes it more versatile.

Features and Benefits

FEATURES:

  • Pressure Response Outlets: allow for even distribution of lytic throughout the length of the catheter
  • Occluding Ball Wire: prevents kinking and provides the proper force to activate pressure response outlets
  • Radiopaque Markers: for ease of placement
  • Sturdier Construction: less catheter material is removed when making slits versus making holes allowing for a stronger catheter with more pushability
  • Supports catheter over bifurcation
  • Compatible with a 0.035” guidewire
  • Longer infusion length options to treat longer clots

A standard sidehole catheter design results in the lytic agent following the path of least resistance causing uneven distribution.

The Uni*Fuse catheter with Pressure Response Outlets and the occluding ball wire allow for even pressure distribution throughout the catheter resulting in a more even distribution of lytic agents.

Safety informations

INDICATION FOR USE:

AngioDynamics Uni-Fuse Infusion System is intended for the administration of fluids, including thrombolytic agents and contrast media, into the peripheral vasculature.


CONTRAINDICATIONS:

The Uni-Fuse Infusion System is contraindicated for use in the coronary vasculature and is not for the infusion of blood or blood products.


WARNINGS AND PRECAUTIONS:

The Uni-Fuse Infusion System is sterile and intended for single patient use and use only by fully trained physicians in angiography and percutaneous interventional procedures. Reuse of single-use devices creates a potential risk of patient or user infections. Contamination of the device may lead to injury, illness or death of the patient. Do not inject contrast medium with a pressure injector if the occluding ball wire is in place. Use an introducer sheath if the puncture is through a synthetic graft. Failure to use an introducer sheath may result in damage to the catheter.

Potential adverse events

POTENTIAL COMPLICATIONS:

Adverse reactions may include, but are not limited to: vessel perforation, dissection, hematoma, stroke, hemorrhage, contrast extravasation, embolism/ thrombus, vaso spasm, drug reaction, neurological deficits, and pain and tenderness.

Indications, contraindications, warnings and instructions for use can be found in the instructions for use supplied with each device. Observe all instructions prior to use. Failure to do so may result in patient complications. 

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model
4F x 135 cm x 10 cm Infusion Pattern
H787124018215
4F x 135 cm x 15 cm Infusion Pattern
H787124018345
4F x 135 cm x 2 cm Infusion Pattern
H787124018335
4F x 135 cm x 20 cm Infusion Pattern
H787124018225
4F x 135 cm x 30 cm Infusion Pattern
H787124018355
4F x 135 cm x 40 cm Infusion Pattern
H787124018365
4F x 135 cm x 5 cm Infusion Pattern
H787124018205
4F x 135 cm x 50 cm Infusion Pattern
H787124018375
4F x 45 cm x 10 cm Infusion Pattern
H787124018255
4F x 45 cm x 15 cm Infusion Pattern
H787124018265
4F x 45 cm x 2 cm Infusion Pattern
H787124018235
4F x 45 cm x 20 cm Infusion Pattern
H787124018275
4F x 45 cm x 5 cm Infusion Pattern
H787124018245
4F x 90 cm x 10 cm Infusion Pattern
H787124018185
4F x 90 cm x 15 cm Infusion Pattern
H787124018295
4F x 90 cm x 2 cm Infusion Pattern
H787124018285
4F x 90 cm x 20 cm Infusion Pattern
H787124018195
4F x 90 cm x 30 cm Infusion Pattern
H787124018305
4F x 90 cm x 40 cm Infusion Pattern
H787124018315
4F x 90 cm x 5 cm Infusion Pattern
H787124018175
4F x 90 cm x 50 cm Infusion Pattern
H787124018325
5F x 135 cm x 10 cm Infusion Pattern
H787124018125
5F x 135 cm x 15 cm Infusion Pattern
H787124018445
5F x 135 cm x 2 cm Infusion Pattern
H787124018435
5F x 135 cm x 20 cm Infusion Pattern
H787124018135
5F x 135 cm x 30 cm Infusion Pattern
H787124018145
5F x 135 cm x 40 cm Infusion Pattern
H787124018155
5F x 135 cm x 5 cm Infusion Pattern
H787124018115
5F x 135 cm x 50 cm Infusion Pattern
H787124018165
5F x 45 cm x 10 cm Infusion Pattern
H787124018025
5F x 45 cm x 15 cm Infusion Pattern
H787124018035
5F x 45 cm x 2 cm Infusion Pattern
H787124018385
5F x 45 cm x 20 cm Infusion Pattern
H787124018045
5F x 45 cm x 5 cm Infusion Pattern
H787124018015
5F x 90 cm x 10 cm Infusion Pattern
H787124018065
5F x 90 cm x 15 cm Infusion Pattern
H787124018425
5F x 90 cm x 2 cm Infusion Pattern
H787124018415
5F x 90 cm x 20 cm Infusion Pattern
H787124018075
5F x 90 cm x 30 cm Infusion Pattern
H787124018085
5F x 90 cm x 40 cm Infusion Pattern
H787124018095
5F x 90 cm x 5 cm Infusion Pattern
H787124018055
5F x 90 cm x 50 cm Infusion Pattern
H787124018105
  • Model : H787124018215
  • Procedure : -
  • Model : H787124018345
  • Procedure : -
  • Model : H787124018335
  • Procedure : -
  • Model : H787124018225
  • Procedure : -
  • Model : H787124018355
  • Procedure : -
  • Model : H787124018365
  • Procedure : -
  • Model : H787124018205
  • Procedure : -
  • Model : H787124018375
  • Procedure : -
  • Model : H787124018255
  • Procedure : -
  • Model : H787124018265
  • Procedure : -
  • Model : H787124018235
  • Procedure : -
  • Model : H787124018275
  • Procedure : -
  • Model : H787124018245
  • Procedure : -
  • Model : H787124018185
  • Procedure : -
  • Model : H787124018295
  • Procedure : -
  • Model : H787124018285
  • Procedure : -
  • Model : H787124018195
  • Procedure : -
  • Model : H787124018305
  • Procedure : -
  • Model : H787124018315
  • Procedure : -
  • Model : H787124018175
  • Procedure : -
  • Model : H787124018325
  • Procedure : -
  • Model : H787124018125
  • Procedure : -
  • Model : H787124018445
  • Procedure : -
  • Model : H787124018435
  • Procedure : -
  • Model : H787124018135
  • Procedure : -
  • Model : H787124018145
  • Procedure : -
  • Model : H787124018155
  • Procedure : -
  • Model : H787124018115
  • Procedure : -
  • Model : H787124018165
  • Procedure : -
  • Model : H787124018025
  • Procedure : -
  • Model : H787124018035
  • Procedure : -
  • Model : H787124018385
  • Procedure : -
  • Model : H787124018045
  • Procedure : -
  • Model : H787124018015
  • Procedure : -
  • Model : H787124018065
  • Procedure : -
  • Model : H787124018425
  • Procedure : -
  • Model : H787124018415
  • Procedure : -
  • Model : H787124018075
  • Procedure : -
  • Model : H787124018085
  • Procedure : -
  • Model : H787124018095
  • Procedure : -
  • Model : H787124018055
  • Procedure : -
  • Model : H787124018105
  • Procedure : -

Questions & Answers

Don't see the answer you're looking for ?