Zilver® PTX® Drug-Eluting Peripheral Stent

Device-Type

Drug-Eluting Stents

Targated Speciality

Endovascular

Manufacturer

Cook Medical


The Zilver PTX Drug-Eluting Peripheral Stent is a self-expanding stent made of nitinol and coated with the drug paclitaxel. It is a flexible, slotted tube that is designed to provide support while maintaining flexibility in the vessel upon deployment. Post-deployment, the stent is designed to impart an outward radial force upon the inner lumen of the vessel, establishing patency in the stented region.


The stent is preloaded in a 6 French delivery catheter. Hand-loading of the stent is not possible. Stent deployment is controlled by rotating the thumbwheel on the handle.


Indicated for improving luminal diameter for the treatment of de novo or restenotic symptomatic lesions in native vascular disease of the above-the-knee femoropopliteal arteries having reference vessel diameter from 4 mm to 7 mm and total lesion lengths up to 300 mm per patient.

Safety informations

CONTRADICTIONS

  • Women who are pregnant, breastfeeding, or plan to become in the next 5 years should not receive a Zilver PTX Drug-Eluting Peripheral Stent. It is unknown whether paclitaxel will be excreted in human milk, and there is a potential for adverse reaction in nursing infants from paclitaxel exposure.
  • Patients who cannot receive recommended anti-platelet and/or anti-coagulant therapy.
  • Patients judged to have a lesion that prevents proper placement of tht stent or stent delivery system.


Potential adverse events

Potential adverse events that may occur include, but are limited to the following:

  • Allergic reaction to anticoagulant and/or antithrombotic therapy or contrast medium
  • Allergic reaction to nitinol
  • Atheroembolization (Blue toe Syndrome)
  • Arterial aneurysm
  • Arterial rupture
  • Arterial thrombosis
  • Arteriovenous fistula
  • Death
  • Embolism
  • Hematoma/hemorrhage
  • Hypersensitivity reactions
  • Infection
  • Infection/abscess formation at access site
  • Ischemia requiring intervention (bypass or amputation of toe, foot, or leg)
  • Pseudoaneurysm formation
  • Renal failure
  • Restenosis of the stented artery
  • Stent embolization
  • Stent malapposition
  • Stent migration
  • Stent strut fracture
  • Vessel perforation or rupture
  • Worsened claudication/rest pain

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Accepts Wire Guide Diameter inch Stent Diameter mm Stent Length mm Minimum Sheath Fr
ZISV
G38404 .035 5 40 6
ZISV
G38407 .035 5 80 6
ZISV
G38414 .035 5 100 6
ZISV
G38415 .035 5 120 6
ZISV
G38416 .035 5 140 6
ZISV
G38463 .035 6 40 6
ZISV
G38479 .035 6 60 6
ZISV
G38480 .035 6 80 6
ZISV
G38481 .035 6 100 6
ZISV
G38482 .035 6 120 6
ZISV
G38483 .035 6 140 6
ZISV
G38486 .035 7 40 6
ZISV
G38487 .035 7 60 6
ZISV
G38488 .035 7 80 6
ZISV
G38489 .035 7 100 6
ZISV
G38490 .035 7 120 6
ZISV
G38491 .035 7 140 6
ZISV
G38495 .035 8 40 6
ZISV
G38516 .035 8 60 6
ZISV
G38518 .035 8 80 6
ZISV
G38523 .035 8 100 6
ZISV
G38532 .035 8 120 6
device-thumbnail
ZISV
  • Model : G38404
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 5
  • Stent Length mm : 40
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38407
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 5
  • Stent Length mm : 80
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38414
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 5
  • Stent Length mm : 100
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38415
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 5
  • Stent Length mm : 120
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38416
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 5
  • Stent Length mm : 140
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38463
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 6
  • Stent Length mm : 40
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38479
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 6
  • Stent Length mm : 60
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38480
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 6
  • Stent Length mm : 80
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38481
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 6
  • Stent Length mm : 100
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38482
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 6
  • Stent Length mm : 120
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38483
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 6
  • Stent Length mm : 140
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38486
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 7
  • Stent Length mm : 40
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38487
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 7
  • Stent Length mm : 60
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38488
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 7
  • Stent Length mm : 80
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38489
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 7
  • Stent Length mm : 100
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38490
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 7
  • Stent Length mm : 120
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38491
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 7
  • Stent Length mm : 140
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38495
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 8
  • Stent Length mm : 40
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38516
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 8
  • Stent Length mm : 60
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38518
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 8
  • Stent Length mm : 80
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38523
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 8
  • Stent Length mm : 100
  • Minimum Sheath Fr : 6
device-thumbnail
ZISV
  • Model : G38532
  • Procedure : -
  • Accepts Wire Guide Diameter inch : .035
  • Stent Diameter mm : 8
  • Stent Length mm : 120
  • Minimum Sheath Fr : 6