Manufacturer > Medtronic > Devices > Enteer Re-entry System

Enteer Re-entry System

Device-Type

CTO Crossing Devices

Targated Speciality

Peripheral Intervention

Manufacturer

Medtronic


The Enteer™ system, consisting of the Enteer re-entry balloon catheter and the Enteer guidewire, provides the physician with control to reliably target the true lumen from the subintimal channel above or below the knee. The Enteer catheter's unique balloon design self-orients toward the true lumen within the subintimal space when inflated. Offset exit ports are located on either side of the device, allowing the Enteer guidewire to reenter into the true lumen.


The Enteer™ Re-entry Guidewire is intended to facilitate placement of balloon dilatation catheters or other intravascular devices during percutaneous transluminal angioplasty (PTA). The Enteer Guidewire is not to be used in cerebral blood vessels. When used as part of the Peripheral System, the Enteer Guidewire is indicated for use to facilitate the intraluminal placement of conventional guidewires beyond stenotic peripheral lesions (including chronic total occlusions) prior to placement of other interventional devices.

The Enteer Re-entry Catheter is indicated for directing, steering, controlling and supporting a guidewire in order to access discrete regions of the peripheral vasculature. When used as part of the Peripheral System, the Enteer Catheter is indicated for use to facilitate the intraluminal placement of conventional guidewires beyond stenotic peripheral lesions (including chronic total occlusions) prior to placement of other interventional devices.

Features and Benefits

Design of Enteer re-entry system

  1. OTW 0.014" and 0.018” guidewire compatibility allows for flexibility during a case and minimizes guidewire exchanges.
  2. With three offerings, the 28° Enteer guidewires are designed to find the Enteer catheter exit port and re-enter true lumen.
  3. When inflated, the flat shaped balloon self-orients toward the true lumen within the subintimal space.

Design of Enteer Re-entry System

180° and offset exit ports on each side of device allow the Enteer guidewire to re-enter the correct port into the true lumen.

Enteer Exit Ports


Flat Shaped Self-orienting Balloon:

The Enteer™ catheter’s unique balloon design self-orients towards the true lumen within the subintimal space when inflated


OTW 0.014” & 0.018” Guidewire Compatible:

Allows for flexibility during your case and minimizes guidewire exchanges


180 and Offset Exit Ports:

Offset exit ports are located on each side of the device allowing the Enteer™ guidewire to re-enter the correct port into the true lumen 


With three offerings, the 28° Enteer™ guidewires are designed to find the Enteer™ catheter exit port and re-enter true lumen



Safety informations

The Enteer™ Re-entry Guidewire is intended to facilitate placement of balloon dilatation catheters or other intravascular devices during percutaneous transluminal angioplasty (PTA). The Enteer™ Guidewire is not to be used in cerebral blood vessels. 

The Enteer™ Re-entry Catheter is indicated for directing, steering, controlling and supporting a guidewire in order to access discrete regions of the peripheral vasculature. 

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Balloon Size(WXHXLmm) Working Length(cm) Guidewire Compatibility(in) Crossing Profile(max in) Sheath Compatibility(F) Description Diamter(in) Length(cm) Tip Reach(mm)
GUIDEWIRE
ENW-FX-014-300 - - - - - Flexible 0.014 300 1.5
GUIDEWIRE
ENW-SD-014-300 - - - - - Standard 0.014 300 1.5
GUIDEWIRE
ENW-SF-014-300 - - - - - Stiff 0.014 300 2.5
RE-ENTRY BALLOON CATHETER
ENB-375-20-135 3.75 × 1.5 × 20 135 ≤ 0.018 0.066 5 - - - -
RE-ENTRY BALLOON CATHETER
ENB-275-20-150 2.75 × 1.0 × 20 150 ≤ 0.018 0.066 5 - - - -
device-thumbnail
GUIDEWIRE
  • Model : ENW-FX-014-300
  • Procedure : -
  • Balloon Size(WXHXLmm) : -
  • Working Length(cm) : -
  • Guidewire Compatibility(in) : -
  • Crossing Profile(max in) : -
  • Sheath Compatibility(F) : -
  • Description : Flexible
  • Diamter(in) : 0.014
  • Length(cm) : 300
  • Tip Reach(mm) : 1.5
device-thumbnail
GUIDEWIRE
  • Model : ENW-SD-014-300
  • Procedure : -
  • Balloon Size(WXHXLmm) : -
  • Working Length(cm) : -
  • Guidewire Compatibility(in) : -
  • Crossing Profile(max in) : -
  • Sheath Compatibility(F) : -
  • Description : Standard
  • Diamter(in) : 0.014
  • Length(cm) : 300
  • Tip Reach(mm) : 1.5
device-thumbnail
GUIDEWIRE
  • Model : ENW-SF-014-300
  • Procedure : -
  • Balloon Size(WXHXLmm) : -
  • Working Length(cm) : -
  • Guidewire Compatibility(in) : -
  • Crossing Profile(max in) : -
  • Sheath Compatibility(F) : -
  • Description : Stiff
  • Diamter(in) : 0.014
  • Length(cm) : 300
  • Tip Reach(mm) : 2.5
  • Model : ENB-375-20-135
  • Procedure : -
  • Balloon Size(WXHXLmm) : 3.75 × 1.5 × 20
  • Working Length(cm) : 135
  • Guidewire Compatibility(in) : ≤ 0.018
  • Crossing Profile(max in) : 0.066
  • Sheath Compatibility(F) : 5
  • Description : -
  • Diamter(in) : -
  • Length(cm) : -
  • Tip Reach(mm) : -
  • Model : ENB-275-20-150
  • Procedure : -
  • Balloon Size(WXHXLmm) : 2.75 × 1.0 × 20
  • Working Length(cm) : 150
  • Guidewire Compatibility(in) : ≤ 0.018
  • Crossing Profile(max in) : 0.066
  • Sheath Compatibility(F) : 5
  • Description : -
  • Diamter(in) : -
  • Length(cm) : -
  • Tip Reach(mm) : -