Manufacturer > MedComp > Devices > SLX SHORT TERM HEMODIALYSIS CATHETER

SLX SHORT TERM HEMODIALYSIS CATHETER

Device-Type

Dialysis Catheter

Targated Speciality

Hemostasis

Manufacturer

MedComp


BASIC SET CONTAINS:

(1) Catheter w/ Stylet

(1) Introducer Needle

(1) Guidewire

(2) Dilators

(1) Scalpel

(1) Tearaway Sheath Introducer

(1) Adhesive Wound Dressing

(2) End Caps

(1) Catheter Clip

(1) 2-0 Suture 

MAX BARRIER TRAY CONTAINS:

(1) Catheter w/ Stylet

(1) Safety

(1) Catheter with Stylets

(1) Introducer Needle

(1) Guidewire

(2) Dilators

(1) Scalpel

(1) Peelable Introducer

(1) Adhesive Wound Dressing

(2) End Caps

(1) Hemo-Cath Hub Clip

(3) 4” x 4” Gauze

(3) 2” x 2” Gauze

(2) Chloraprep

(1) 5cc Syringe

(2) Pre-Filled Saline Syringes

(1) 2-0 Silk Suture

(3) Safety Hypodermic Needles

(1) Hemostat

(1) Fenestrated Drape

(1) 5cc Lidocaine

(1) Filter Straw

(1) Surgical Gloves

(1) Needle Stick Pad

(1) Steri-Strips

(2) Face Mask

(1) Lidocaine/Saline Stickers

(1) Surgical Tape

(1) XL Gown

(1) Bouffant Cap

(1) Surgical Mask

Features and Benefits

  • Larger 14F luminal design allows for improved flow rates.
  • Silicone material provides biocompatibility and kink resistance.
  • Fast Track™ Stylet and round catheter permits easier insertion and less patient discomfort.
  • MRI compatible.

Safety informations

INDICATIONS FOR USE:

The Medcomp® SLX Double Lumen Catheter can be utilized for temporary access for hemodialysis, hemoperfusion or apheresis therapy. The cannula may be inserted via the Seldinger technique due to the inner Teflon stylet, increasing linear strength. The stylet is removed after insertion, leaving the soft silicone cannula in the body. The flexible silicone make-up conforms well to the vessel anatomy, resulting in higher patient tolerance during extended use.


Contraindications

The Subclavian Approach is NOT recommended for use with the Medcomp® SLX Double Lumen Subclavian-Femoral Catheter in Hemodialysis or Hemoperfusion Procedures used for the management of acute poisoning or other situations in which a ventilator might be used due to risk of traumatic pneumothorax posing a dangerous complication for the patient.


WARNINGS:

• In the rare event that a hub or connector separates from any component during insertion or use, take all necessary steps and precautions to prevent blood loss or air embolism and remove the catheter immediately.

• Do not advance the stainless steel guidewire or catheter if unusual resistance is encountered.

• Do not insert or withdraw the guidewire forcibly from any component. The wire could break or unravel. If the guidewire becomes damaged, the catheter and guidewire must be removed together.

• Federal Law (USA) restricts the device to sale by or on the order of a physician. 


Potential adverse events

• Air Embolism • Bacteremia • Brachial Plexus Injury • Cardiac Arrrythmia • Cardiac Tamponade • Central Venous Thrombosis • Endocarditis • Exit Site Infection • Exsanguination • Femoral Artery Bleed • Femoral Nerve Damage • Hematoma • Hemorrhage • Hemothorax • Inferior Vena Cava Puncture • Laceration of the vessel • Luminal Thrombosis • Mediastinal Injury • Perforation of the vessel • Pleural Injury • Pneumothorax • Retroperitoneal Bleed • Right Artial Puncture • Septicemia • Subclavian Artery Puncture • Subcutaneous Hematoma • Superior Vena Cava Puncture • Thoracic Duct Laceration • Vascular Thrombosis • Venous Stenosis

Device Documents

Related Device SKUs

* Select 2 or more (upto 4) SKUs to compare.
SKU Name Device SKUs Model Size(F) Length(cm) Material Type
SLX CATHETER
MC061402 14 15 Silicone BASIC SET
SLX CATHETER
MC061403 14 20 Silicone BASIC SET
SLX CATHETER
MC061404 14 24 Silicone BASIC SET
SLX CATHETER
MC061405 14 30 Silicone BASIC SET
SLX CATHETER
MC061422MB 14 15 Silicone MAX BARRIER TRAY
SLX CATHETER
MC061423MB 14 20 Silicone MAX BARRIER TRAY
SLX CATHETER
MC061424MB 14 24 Silicone MAX BARRIER TRAY
SLX CATHETER
MC061425MB 14 30 Silicone MAX BARRIER TRAY
device-thumbnail
SLX CATHETER
  • Model : MC061402
  • Procedure : -
  • Size(F) : 14
  • Length(cm) : 15
  • Material : Silicone
  • Type : BASIC SET
device-thumbnail
SLX CATHETER
  • Model : MC061403
  • Procedure : -
  • Size(F) : 14
  • Length(cm) : 20
  • Material : Silicone
  • Type : BASIC SET
device-thumbnail
SLX CATHETER
  • Model : MC061404
  • Procedure : -
  • Size(F) : 14
  • Length(cm) : 24
  • Material : Silicone
  • Type : BASIC SET
device-thumbnail
SLX CATHETER
  • Model : MC061405
  • Procedure : -
  • Size(F) : 14
  • Length(cm) : 30
  • Material : Silicone
  • Type : BASIC SET
device-thumbnail
SLX CATHETER
  • Model : MC061422MB
  • Procedure : -
  • Size(F) : 14
  • Length(cm) : 15
  • Material : Silicone
  • Type : MAX BARRIER TRAY
device-thumbnail
SLX CATHETER
  • Model : MC061423MB
  • Procedure : -
  • Size(F) : 14
  • Length(cm) : 20
  • Material : Silicone
  • Type : MAX BARRIER TRAY
device-thumbnail
SLX CATHETER
  • Model : MC061424MB
  • Procedure : -
  • Size(F) : 14
  • Length(cm) : 24
  • Material : Silicone
  • Type : MAX BARRIER TRAY
device-thumbnail
SLX CATHETER
  • Model : MC061425MB
  • Procedure : -
  • Size(F) : 14
  • Length(cm) : 30
  • Material : Silicone
  • Type : MAX BARRIER TRAY

Questions & Answers

Don't see the answer you're looking for ?